Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

Delta VFD450C43S-00 Inverter - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

Solarwechselrichter/elektrisch/

Delta VFD450C43S-00 Inverter

This is a Delta C2000+ Series 45kW/60HP 400V-class high-performance vector inverter. It adopts FOC (Field-Oriented Control) technology and supports three-motor drive: induction motor, permanent magnet synchronous motor (PMSM), and synchronous reluctance motor (SynRM). It features 150% overload capacity for 60 Sekunden, built-in PLC (10k steps) and DC reactor, suitable for high-dynamic loads such as extruders, ...

  • Produktdetails

This is a Delta C2000+ Series 45kW/60HP 400V-class high-performance vector inverter. It adopts FOC (Field-Oriented Control) technology and supports three-motor drive: induction motor, permanent magnet synchronous motor (PMSM), and synchronous reluctance motor (SynRM). It features 150% overload capacity for 60 Sekunden, built-in PLC (10k steps) and DC reactor, suitable for high-dynamic loads such as extruders, cranes, Werkzeugmaschinenspindeln, and is a mainstream model in industrial automation.

  1. Full Model Code Breakdown (VFD450C43S-00)
SectionMarkingBeschreibungTechnical Note
1VFDProduct Series PrefixStandard identifier for Delta AC drives
2450Rated Power CodeCorresponds to 45kW/60HP (Heavy Duty rating)
3CSeries CodeC2000+ Series (upgraded from C2000), high-performance vector control
44Spannungsklasse400V class (3-phase 380–480V, global 400V grid compatible)
53Phase3-phase input / output
6SStructure/SpecStandard type (no conduit box, UL open type installation)
70Configuration CodeBasic version, no built-in EMC filter, Schutzart IP20
  1. Wichtige technische Parameter
ArtikelWertBemerkungen
ProduktserieVFD-C2000+ (C2000 Plus)Delta flagship vector inverter, upgraded from C2000
Rated Power45kW / 60HPHeavy-duty design for high-dynamic loads
Rated Output Current91A (50/60Hz)Heavy Duty (HD) rating; Standard Heavy Duty (SHD) up to 113A
Input Voltage3-phase 380–480V, 50/60HzWide voltage range, adapts to grid fluctuations
Output Voltage3-phase 0–input voltagePWM control, linear variation with frequency
Control MethodFOC Vector Control / V/F ControlSensorless vector / Closed-loop vector; speed ratio 1:2000
Motor CompatibilityInduction / PMSM / SynRMTri-motor drive for versatile applications
Überlastfähigkeit150% rated current for 60s; 180% for 3sIdeal for shock loads and heavy industrial environments
Built-in ComponentsDC reactor, SPS (10k steps), brake unit interfaceStandard DC reactor, PF ≥ 0.95
CommunicationBuilt-in Modbus RTU, supports extension modulesPROFINET, EtherCAT, EtherNet/IP available
Digitale Eingänge8 Punkte (expandable to 16)Programmable for versatile control
Analog Inputs2 Punkte (voltage/current selectable)0–10V / 4–20mA for remote speed reference
Relay Outputs3 Punkte (general/alarm/run)Status indication and fault relay
SchutzgradIP20 (Standard)IP54 kit optional for harsh environments
Umgebungstemperatur-10℃ to +55℃Wide temp range, PCB coating (3C3 level)
Abmessungen (mm)H×W×D: 480×260×375 (Frame D)Standard industrial size for cabinet mounting
GewichtApprox. 29kgStandard weight, einfache Installation
  1. Typische Anwendungen
  2. Heavy-Duty Industrial Applications

Metalworking: Machine tool spindles, milling machines, grinders requiring high-precision speed/torque control

Plastic & Rubber Machinery: Extruder, injection molding machines with stable pressure control and high dynamic response

Hoisting & Conveying: Cranes, Aufzüge, port machinery needing 150% overload for start-up shock

Mining Machinery: Crushers, conveyors for harsh environments and frequent starts/stops

  1. General Industrial Loads

Fans & Pumps: Large HVAC, wastewater treatment; energy-saving algorithm, bis zu 30%+ energy reduction

Textile Machinery: Carding machines, spinning frames with high low-speed torque and precise synchronization

Packaging Machinery: High-speed lines requiring smooth acceleration/deceleration for improved efficiency

  1. Special Technical Advantages

Multi-motor Synchronization: Built-in PLC for complex logic and multi-axis sync

Energy Management: Power monitoring for consumption analysis and optimization

Remote Maintenance: Modbus/TCP for SCADA integration and remote diagnosis

Harsh Environments: -10℃ to +55℃ operation, PCB coating for dust and humidity resistance

  1. Replacement Models

4.1 Delta Upgrades / Replacements

ErsatzmodellMain DifferenceAnwendung
VFD450C43A-00With conduit box, UL enclosed typeNordamerikanischer Markt, standardized wiring
VFD450C43S-21Built-in EMC filter + conduit boxSystems with high EMC requirements
VFD450C43S-01With STO (Sicher abgeschaltetes Drehmoment)Cranes, elevators and safety-critical applications
VFD450C43S-4GPROFINET communicationSmart manufacturing with industrial Ethernet

4.2 Cross-Brand Equivalents

MarkeModellKey Matching ParametersNotizen
ABBACS880-04-092A-545kW, 92A, 400V, DTC controlHigh-performance vector drive for complex loads
SchneiderATV930U45N445kW, 91A, 400V, VektorsteuerungBuilt-in PLC, multi-protocol support
SiemensG120XA 6SL3220-3YE48-0UA045kW, 91A, 400V, fan/pump optimizedHVAC-focused, high energy efficiency
FujiFRN0090G2S-4G45kW, 90A, 400V, sensorless vectorBuilt-in brake unit for frequent starts/stops
  1. Auswahl & Application Notes
  2. Lastabgleich

Heavy loads (Extruder, cranes) must use HD rating (150%/60S) for stable long-term operation

General loads (Fans, Pumps) may use SHD rating (110%/60S) for cost efficiency

Shock loads (presses, Brecher) recommend 20% power oversizing to avoid frequent tripping

  1. Braking System

Standard unit has no built-in brake unit; external brake unit + resistor required for fast stopping

For braking torque >20%, recommend Delta DBU-4055 brake unit + DR-1200 resistor

  1. Communication

Base version: Modbus RTU only

PROFINET / EtherCAT / EtherNet/IP require optional DVCCNET-xxx card

  1. Installation & Cooling

Must be mounted vertically with ≥100mm clearance above and below

Derate 1% per °C above 40°C or add forced cooling

IP54 kit recommended for dusty environments to extend service life

  1. Wartung

Regularly inspect fan and main capacitor; use built-in lifetime diagnosis

Clean heat sink every 6 months to prevent overheating

Keep firmware updated via Delta ISPSoft software

Delta VFD450C43S-00 is an outstanding 45kW vector inverter with tri-motor drive, 150% heavy-duty capacity, built-in PLC and DC reactor, making it ideal for high-demand industrial automation. Select based on load type, braking and communication needs, or choose upgraded variants for enhanced performance. Its wide-temperature design and high reliability ensure stable operation in harsh environments, supporting productivity and energy savings.

Delta VFD450C43S-00 – Key Selection Notes (Field Version)

  1. Leistung & Lastabgleich

This drive is Heavy Duty (HD): 45kW/91A, 150%/60s overload for extruders, cranes, Brecher, Werkzeugmaschinen.

Fans/pumps can be used as SHD 60kW, but oversizing is not recommended.

For shock loads (presses, Brecher), oversize by one power level or verify overload margin.

  1. Stromspannung & Grid

3-phase 380–480V input, 50/60Hz universal.

For unstable or high-harmonic grids: DC reactor is built-in, but an input AC reactor is still recommended.

  1. Motor Compatibility

Supports induction / PMSM / SynRM in three drive modes.

Auto-tuning is mandatory for PMSM; otherwise torque and speed will be unstable.

  1. Bremsen & Stopping (Critical)

VFD450C43S-00 has NO built-in brake unit!

For fast stopping or overhauling loads (cranes, Aufzüge, downhill conveyors):

External brake unit + resistor is required.

Empfohlen: Delta DBU-4055 brake unit.

  1. Installation, Cooling & Protection

Must be mounted vertically with ≥100mm ventilation space top and bottom.

Derate when ambient > 40°C (≈1% per °C).

Unit is IP20 open type; use enclosure or IP54 kit in dust, moisture or oil.

  1. EMC

-00 version has NO built-in EMC filter.

For sensitive devices (sensors, SPS): add external EMC filter + shielded cable + proper grounding.

  1. Sicherheit

This model does NOT include STO (Sicher abgeschaltetes Drehmoment).

For safety-related applications (hoists, machines), use STO-equipped model (-01 suffix) or external safety relay.

  1. Communication & Expansion

Standard only Modbus RTU.

PROFINET / EtherCAT / EtherNet/IP require optional communication card.

  1. Spare Parts & Wartung

Recommended spares: cooling fan, Kondensatoren, brake resistor.

Use keypad parameter copy for fast commissioning of multiple drives.

 

Vorher:

Nächste:

Hinterlassen Sie eine Antwort

Eine Nachricht hinterlassen