Application Summary of CIMR‑AB4A0018FBA (A1000, HD 5.5kW / ND 7.5kW, 380V) Wechselrichter
Unit Specification: Heavy-Duty(HD) 5.5kW, Normal-Duty(ND) 7.5kW, PG/PG-less vector control, high starting torque. Mainly applied to two categories: high-precision variable speed regulation & constant-torque loads, and energy saving for fans & Pumps.
- Modellcode-Definition
| Codesegment | Code | Beschreibung |
| Produkttyp | CIMR | Standard part code for Yaskawa inverters |
| Serienkennung | A | A1000 general-purpose high-performance vector inverter series |
| Design Revision | B | 2nd generation design (A=1st generation, B=2nd generation) |
| Spannungsklasse | 4A | 3-phase 400V class (380~480VAC) |
| Capacity Code | 18 | Matched motor rating: 5.5kW HD /7.5kW ND, rated output current:17.5A |
| Kontrolltyp | F | Standard control (SVPWM current vector control) |
| Option/Keypad | BA | Equipped with standard digital operator; model without BA = keypad excluded |
- Grundlegende technische Spezifikationen
| Spec Category | Einzelheiten |
| Grundlegende Informationen | Modell: CIMR-AB4A0018FBA |
| Serie: A1000 High-Performance Vector Inverter | |
| Marke: Yaskawa | |
| Bestell-Nr.: CIMR-AB4A0018FBA | |
| Electrical Data | Eingang: 3-phase 380~480VAC, 50/60Hz |
| Allowable voltage fluctuation: -15% ~ +10% | |
| Ausgangsspannung: 0 ~ input voltage (frequency-dependent) | |
| Ausgangsfrequenz:0~400Hz (parameter configurable) | |
| Rated motor:5.5kW(HD)/7.5kW(ND), rated output current:17.5A | |
| Kontrolle: Advanced SVPWM current vector control, compatible with induction, IPM & SPM motors | |
| Performance Index | Starting torque:150% rated torque @0.3Hz |
| Speed range:1:200 (PG-less vector),1:1000 (PG vector) | |
| Speed accuracy:±0.2%(PG-less), ±0.01%(PG-equipped) | |
| Overload rating:150% Nennstrom für 60s;200% rated current for 0.5s | |
| Struktur & E/A | Enclosure class:IP20 (NEMA1) |
| Kühlung: Zwangsluftkühlung | |
| Standard comm.:Modbus; optional:PROFIBUS-DP, DeviceNet, EtherNet/IP | |
| AUS:6 Punkte, TUN:2 Punkte, KI:2 Punkte, ZUM:2 Punkte | |
| Zulassungen | CE (LVD 2014/35/EU & EMC 2014/30/EU) |
| UL, CSA, ISO9001 & ISO14001 certified | |
| Compliant with EN954-1 Cat.3 & IEC/EN61508 SIL2 safety standard |
- Full Series List (400V-Klasse, BA with Keypad)
| Capacity Code | Modell | Motor Rating HD/ND | Nennausgangsstrom |
| 2 | CIMR-AB4A0002FBA | 0.4kW/0.75kW | 2.2A |
| 4 | CIMR-AB4A0004FBA | 0.75kW/1.5kW | 3.7A |
| 5 | CIMR-AB4A0005FBA | 1.5kW/2.2kW | 5.0A |
| 7 | CIMR-AB4A0007FBA | 2.2kW/3.0kW | 6.8A |
| 9 | CIMR-AB4A0009FBA | 3.0kW/4.0kW | 8.5A |
| 11 | CIMR-AB4A0011FBA | 4.0kW/5.5kW | 10.5A |
| 18 | CIMR-AB4A0018FBA | 5.5kW/7.5kW | 17.5A |
| 24 | CIMR-AB4A0024FBA | 7.5kW/11kW | 23.0A |
| 31 | CIMR-AB4A0031FBA | 11kW/15kW | 30.0A |
| 44 | CIMR-AB4A0044FBA | 15kW/18.5kW | 42.0A |
| 55 | CIMR-AB4A0055FBA | 18.5kW/22kW | 52.0A |
| 60 | CIMR-AB4A0060FBA | 22kW/30kW | 58.0A |
| 75 | CIMR-AB4A0075FBA | 30kW/37kW | 72.0A |
| 90 | CIMR-AB4A0090FBA | 37kW/45kW | 87.0A |
| 110 | CIMR-AB4A0110FBA | 45kW/55kW | 105.0A |
Notiz: Full series covers 0.4kW~355kW; above is frequently used models only
- Cross Model & Leitfaden zum markenübergreifenden Austausch
4.1 Internal Yaskawa Model Upgrade
| Altes Modell | New Replacement | Replacement Remark |
| CIMR-AB4A0018FBA | CIMR-HB4A0018FBC | H1000 heavy-duty series for crane dedicated application |
| CIMR-AB4A0018FBA | CIMR-VB4A0018FBA | Cost-effective V1000 compact vector inverter alternative |
4.2 Markenübergreifender Äquivalentvergleich
| Marke | Serie | Äquivalentes Modell | Kernunterschied |
| Siemens | SINAMICS G120 | 6SL3224-0BE25-5UA0 | Höhere Kosten, superior Profinet integration, powerful software |
| Schneider | Altivar 61 | ATV61HD75N4 | Abundant functions, strong adaptability, Chinese HMI available |
| ABB | ACS880 | ACS880-01-032A-3 | Fast dynamic response for high-precision use, premium price |
| Mitsubishi | FR-A840 | FR-A840-00180-2-60 | High cost-performance, user-friendly for general industrial drives |
- Anwendungsumgebung & Branchenfälle
5.1 Empfohlene Anwendungsszenarien
| Industrie | Typische Ausrüstung | Core Benefits |
| Fluid Machinery | Wasserpumpen, Fans, Kompressoren | 30~50% energy saving, smooth flow/pressure adjustment, reduced mechanical shock |
| Metal Working | Lathes, Fräsmaschinen, Schleifmaschinen | High-accuracy speed control to improve machining precision & product quality |
| Lifting Equipment | Aufzüge, Hebezeuge, Hebebühnen | Precise torque control for smooth start/stop and reliable operation |
| Materialhandhabung | Bandförderer, electric hoists, AGVs | Stepless speed regulation, higher throughput & geringerer Stromverbrauch |
| Verpackung | Food packaging lines, Druckmaschinen | Synchronized drive to boost production speed & cut material waste |
| Textile | Spinning & weaving machines | Constant tension control to reduce yarn breakage & raise yield rate |
5.2 Not Recommended Installation Conditions
Explosiv & flammable atmosphere (explosion-proof inverter required instead)
Severe EMI environment (external EMC filter mandatory)
Altitude over 1000m with no power derating (consult manufacturer for derating specs)
Locations with vibration exceeding 0.6G (special mounting structure required)
5.3 Practical Retrofit Cases
Case1: Energy Saving Retrofit on Food Packaging Conveyor
Load: Biscuit packaging conveyor system
Before upgrade: Direct-on-line startup with heavy mechanical impact & high power waste
After upgrade: CIMR-AB4A0018FBA realizes soft start/stop & speed auto-adjustment following production cycle
Ergebnis: 30% longer equipment service life, 35% power reduction, 5% higher finished product rate
Case2: Central Air-conditioning Chilled Water Pump Retrofit
Load:5.5kW cooling circulation pump
Before upgrade: Constant-speed running with flow throttled by valve leading to huge energy loss
After upgrade: Inverter adjusts pump speed automatically based on return water temperature
Ergebnis: Approx.28,000 kWh annual power saving, payback period:6 Monate
- Compliance bei Lufttransporten & Certification Manual
6.1 Air Transport Compliance Judgment
Built-in battery: No lithium cell equipped, only passive capacitors installed; excluded from UN3480/UN3481 lithium battery transport regulation
Shipping classification: General electrical goods, no UN38.3 test report or air identification certificate needed
Verpackung: Original factory carton or ISTA-certified packaging with anti-static & moisture-proof protection
6.2 Key Product Certifications
| Zertifikat | Standard | Valid Region | Acquisition |
| CE | LVD 2014/35/EU + EMC 2014/30/EU | EU & EEA | Supplied by Yaskawa original factory with shipment |
| UL | UL508C Industrial Control Standard | USA, Kanada | Original supply; certificate number available on Yaskawa official website |
| ISO | ISO9001/ISO14001 | Global | Group-level certification, documents accessible from Yaskawa corporate |
- Auswahltipps & Kurzreferenzregeln
7.1 A1000 Selection Mnemonic
AB4A for three-phase 400V, capacity code links output ampere,
switch HD/ND duty freely, BA=with keypad, AA=without spare,
robust vector performance, fits most general industry drives.
7.2 Quick Calculation Rules
400V model prefix: CIMR-AB4A (with keypad) / CIMR-AA4A (keypad-less)
Ca. ND kW ≈ Capacity Code ×0.1; Ca. HD kW ≈ Capacity Code ×0.06
Code 0018 = HD5.5kW / ND7.5kW, rated output 17.5A
Detailed Field Application Breakdown
- General Fluid Energy Saving (Fans & Pumps, prefer ND7.5kW rating)
- HVAC Central Air Conditioning
Chilled water pumps, cooling tower fans, AHU supply fans
Funktionsprinzip: Variable speed regulated by water temperature & differential pressure instead of valve throttling; 30~50% power saved
Anwendung: Single pump ≤7.5kW for shopping malls, Bürogebäude & factory central air systems
- Wasserversorgung & Drainage System
Plant service water pumps, booster pumps for secondary water supply, sewage & rainwater lift pumps
Constant pressure control: Closed-loop regulation with pressure transducer; low-speed running at night to cut idle loss
Suitable for residential pump rooms & small factory wastewater treatment stations
- Boiler Auxiliary Equipment
Induced draft fan, forced draft fan & boiler feed pump with auto speed adjustment by furnace negative pressure.
- Förderer & Bulk Material Handling (Constant-torque, select HD5.5kW)
- Light Industry Assembly Conveyors
Food processing lines, carton packing conveyors, bottle filling & small roller bed lines
Vorteil: Soft start/stop prevents belt rupture; multi-speed switching matches production tact time
- Small Mining & Aggregate Feeding Equipment
Light-duty belt feeders, spiral screw conveyors for grain, powder and sand transportation
Besonderheit: 150% low-frequency starting torque suits heavy inrush load at startup
- Warehouse Sorting Equipment
Small sorting conveyors and pallet roller conveyors.
III. CNC & Machining Tools (High-precision speed control via vector drive)
- Spindle drive for conventional lathe, bench milling & surface grinder: 0~400Hz wide frequency range enables stepless speed change to replace traditional gearbox and improve surface finish; ±0.2% speed accuracy for PG-less vector mode
- Bench grinders, polishing machines & small wire drawing machines.
- Textile Machinery (Primary constant tension control application)
Twisting frames, small looms, cone winding machines, fabric setting pull rollers
Nachfrage: Low-speed high torque & stable tension to avoid yarn breakage; A1000 vector drive perfectly matches 5.5kW rated load
- Light Lifting & Hoisting Applications
Only for light-duty lifting; heavy crane uses H1000 series instead
Small cargo lifting platforms, fixed compact freight elevators, miniature electric hoists
Vorteil: Smooth start/stop prevents load slipping with zero-speed holding torque to eliminate mechanical impact
- Rubber, Plastik & Verpackungsmaschinen
- Auxiliary feed screw for plastic extruder & small pelletizer;
- Horizontal flow wrappers, Siegelmaschinen & film winding machines with constant winding tension control.
VII. Grain & Feed Processing Equipment
Auxiliary drives for grinders, feed mixers, grain elevators and separator fans.
Prohibited & Unadvisable Installation Conditions
- Explosion-prone chemical workshops: Standard IP20 design without explosion-proof certification; EX-type inverter required;
- Altitude over 1000m: Minimum 10% power derating mandatory otherwise overheat alarm occurs;
- Equipment with severe cyclic shock & Vibration (impact crushers, forging hammers): Loose terminals and PCB damage caused by continuous vibration;
- Direct driving of large shock loads (heavy gantry cranes, large air compressors): Insufficient rated power, select high-power H1000 series;
- Outdoor open-air mounting without control cabinet: No ingress protection; rain & dust damage internal power modules.
Verified On-site Application Cases
- Fall 1: ND rated 7.5kW Chilled Water Pump
Injection molding plant pump retrofit: Original valve throttling at fixed speed; variable frequency control by coolant temperature saves around 26,000 kWh yearly.
- Fall 2: HD rated 5.5kW Packaging Line Conveyor
Biscuit production main transport with frequent start-stop; full-load startup at 0.5Hz without slip; equipment failure rate cut by 70%.
Quick Selection Tip
Fans & Water Pumps → apply ND 7.5kW rating
Förderer, Werkzeugmaschinen, Textile Equipment → apply HD 5.5kW rating
Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien



















NH42-63-318x560.png)




