ABB Molded Case Circuit Breaker AC250-4P-150A - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

cortacircuitos/

ABB Molded Case Circuit Breaker AC250-4P-150A

Segmento de modeloMeaningComplete Model Example
AC250A-series molded case circuit breaker, Type C breaking capacity (25el), frame current 250AA2C 250 TMF 150-1500 4p F F
4PAG4-polo (3-fase + Neutral), suitable for TN-C-S/TN-S systems, provides neutral line protection1SDA068783R1 (ABB official order number)
150ARated operating current 150A, thermal-magnetic trip unit setting range 150-1500AThermal protection current Ith=150A, magnetic protection current Im=1500A
TMFThermal-magnetic trip unit, provides overload long-time delay and short-circuit instantaneous protectionStandard configuration, no external protection device required
FFFixed mounting method, front terminal connection (rear connection/plug-in type optional)Suitable for standard distribution cabinet installation

  • Detalles del producto

Complete Model Interpretation (Formula A2 Series)

Segmento de modeloMeaningComplete Model Example
AC250A-series molded case circuit breaker, Type C breaking capacity (25el), frame current 250AA2C 250 TMF 150-1500 4p F F
4PAG4-polo (3-fase + Neutral), suitable for TN-C-S/TN-S systems, provides neutral line protection1SDA068783R1 (ABB official order number)
150ARated operating current 150A, thermal-magnetic trip unit setting range 150-1500AThermal protection current Ith=150A, magnetic protection current Im=1500A
TMFThermal-magnetic trip unit, provides overload long-time delay and short-circuit instantaneous protectionStandard configuration, no external protection device required
FFFixed mounting method, front terminal connection (rear connection/plug-in type optional)Suitable for standard distribution cabinet installation
  1. Parámetros eléctricos básicos
Elemento de parámetroValorDescripción
Tensión nominal400V y (50/60Hz), 690V AC optionalCumple con IEC 60947-2 estándar, insulation voltage Ui=690V
Corriente nominal150ALong-term stable operating current at 40℃ ambient temperature
Marco actual250AMaximum current carrying capacity of the circuit breaker
Capacidad de ruptura25el (400V y)Type C breaking capacity, suitable for general industrial and commercial buildings
Trip CharacteristicsProtección térmica: No operation at 1.05×Ith, operation within 1 hour at 1.3×IthEffectively protects motors and cables from overload and short-circuit damage
Protección magnética: Instantaneous operation at 10×Ith (1500A)
Número de polo4PAG (3L+N)All poles have protection function, neutral line can also be disconnected
Método de conexiónFront connection (estándar), rear connection optionalCopper bar connection, bolt fastening, reliable contact
Clase de protecciónIP20Suitable for indoor cabinet installation, prevents finger contact with live parts

III. Structural and Functional Characteristics

  1. Mechanical and Physical Characteristics

Dimensiones: 90milímetros (W.) × 160mm (h) × 105mm (D) (standard 4-pole size), complies with modular design, easy for side-by-side installation

Método de operación: Rotary handle (red for OFF/green for ON), with clear position indication, moderate operating torque

Vida mecánica: 20,000 veces (open-close cycles), Vida eléctrica: 5,000 veces (at rated current)

Método de montaje: Fixed type (estándar), plug-in/withdrawable type optional, suitable for different maintenance requirements

  1. Funciones de protección (TMF Thermal-Magnetic Trip)
Tipo de protecciónOperating ConditionEscenario de aplicación
Overload Long-Time DelayDelayed operation based on heating when current exceeds rated valueProtection against slow overloads such as motor locked rotor and cable overload
Short-Circuit InstantaneousInstantaneous tripping when current reaches 10*rated value (1500A)Protection against severe faults such as line short circuit and equipment insulation breakdown
Función de aislamientoHas isolation capability when handle is in OFF positionEnsures complete circuit disconnection during maintenance, guarantees personnel safety
Phase Unbalance ProtectionOperates when three-phase current difference exceeds set valueProtection against motor phase loss operation, extends equipment service life
  1. Accessory Expansion Capability

Optional Under-Voltage Release (UVR): Trips when voltage is below 70% of rated value, prevents equipment damage caused by low-voltage operation

Optional Shunt Trip: Remote control tripping, realizes functions such as fire linkage

Optional Auxiliary Contacts: 2NO+2NC, used for status indication or control circuit

Optional Alarm Contacts: 1NO, used for fault alarm signal output

  1. Escenarios de aplicación y recomendaciones de selección
  2. Escenarios de aplicación típicos
Application FieldSpecific UsageSelection Advantage
Automatización IndustrialControl and protection of 380V three-phase motors (≤75kW)Dual protection against overload and short circuit, adapts to motor starting impact
Edificios ComercialesMain switch for air conditioning systems, bombas de agua, fans and other equipment4-diseño de poste, suitable for building distribution TN-S system
Centros de datosUPS output end, rack power distribution unit main switchReliable breaking capacity, ensures power supply continuity
Residential BuildingsCommunity distribution room, unit building main switchCompact size, fácil instalación, low maintenance cost
  1. Key Selection Matching Points
  2. Load Type Matching

Motor load: Select 1.2-1.3×motor rated current (150A suitable for ≤75kW motors)

Lighting/socket load: Select 1.0-1.1×calculated current

Mixed load: Select according to the largest load type, taking into account other loads

  1. Breaking Capacity Selection

General distribution system: 25el (Tipo C) is sufficient

Locations close to transformers or with large short-circuit current: Select models with 36kA (Type N) or 50kA (Type H) capacidad de ruptura

  1. System Earthing Configuration

TN-C-S/TN-S system: 4-pole circuit breaker must be selected to provide neutral line protection

TT system: 3P or 4P can be selected as required

  1. Puntos de instalación y mantenimiento
  2. Especificaciones de instalación

Requisitos ambientales: Temperature -5℃~+40℃ (derating required when exceeding 40℃, 2% derating per 1℃ increase), humedad ≤95% (sin condensación)

Installation Position: Vertical installation (handle upward), reserve ≥50mm space above and below to ensure good heat dissipation

Requisitos de cableado: Copper bar cross-sectional area ≥70mm² (for 150A current), bolt torque complies with ABB specifications (20Nm for M8 bolts)

  1. Recomendaciones de mantenimiento

Regular inspection (every 6 meses): Check handle operation flexibility, terminal tightness, and trip unit function test

Manejo de fallas: Troubleshoot the cause (overload/short circuit) after tripping, reset only after fault elimination, forced closing is strictly prohibited

Life management: Replace in time when mechanical/electrical life is reached to ensure protection reliability

  1. Replacement and Upgrade Solutions
  2. Same-Series Replacement
t
Original ModelReplacement ModelDifference Description
AC250-4P-150A (Tipo C)A2N 250 TMF 150-1500 4p F FType N breaking capacity 36kA, suitable for occasions with large short-circuit current
AC250-4P-150A (TMF)A2C 250 PR211-LI 150 4p F FElectronic trip unit with adjustable protection parameters, suitable for complex loads
  1. Upgrade Solutions

Intelligent Upgrade: Replace with Formula A2 series model with PR221-LI electronic trip unit, supports communication function (Modbus) to realize remote monitoring and fault diagnosis

Breaking Capacity Upgrade: Upgrade to XT series (p.ej., XT3S 250 TMD 150 4PAG), breaking capacity up to 50kA, suitable for heavy industry environments

VII. Resumen

ABB Molded Case Circuit Breaker AC250-4P-150A (complete model A2C 250 TMF 150-1500 4p F F) is a cost-effective and reliable general-purpose protection electrical device, suitable for most 400V low-voltage distribution systems. Its core advantages are:

  1. 4-Pole Full Protection: Suitable for modern building TN-S distribution system, neutral line can also get effective protection
  2. 25kA Breaking Capacity: Meets the short-circuit protection requirements of general industrial and commercial buildings
  3. TMF Thermal-Magnetic Trip: No external protection device required, easy installation and maintenance
  4. Modular Design: Supports expansion of various accessories to adapt to different application scenarios

Selection should be comprehensively considered according to load type, short-circuit current size and system earthing configuration to ensure the circuit breaker matches the system and provides the best protection effect.

Detailed Comparison Table of ABB AC250-4P-150A and Same-Specification Molded Case Circuit Breakers of Mainstream Brands

  1. Core Parameter Comparison Table (250A Frame, 4PAG, 150A, Thermal-Magnetic Trip, 25kA Breaking Capacity)
Elemento de parámetroABB Formula A2Schneider EZDSchneider CVSSiemens 3VC2Chint NXM
Complete ModelA2C 250 TMF 150-1500 4p F F (AC250-4P-150A)EZD250M150EL 4PCVS250F TMD 150 4PAG3VC2225-1TM30-0AA0NXM-250S/4300B 150A
Order Number1SDA068783R1LV510349LV5253303VC22251TM300AA0NXM-250S/4300B-150
Corriente nominal150A150A150A150A150A
Marco actual250A250A250A250A250A
Número de polo4PAG (3L+N, full protection)4PAG (3L+N, full protection)4PAG (3L+N, full protection)4PAG (3L+N, full protection)4PAG (3L+N, full protection)
Capacidad de ruptura25el (400V y)25el (400V y)36el (400V y)25el (400V y)25el (400V y)
Tipo de unidad de disparoTMF (Thermal-magnetic, 150-1500A)EL (Thermal-magnetic, 150-1500A)TMD (Thermal-magnetic, 150-1500A)TM30 (Thermal-magnetic, 150-1500A)Thermal-magnetic (150-1500A)
Tensión nominal400V y (50/60Hz), 690V optional400V y (50/60Hz)400V y (50/60Hz)400V y (50/60Hz)400V y (50/60Hz)
Voltaje de aislamiento690V690V690V690V690V
Método de montajeFixed, front connection (FF)Fixed, front connectionFixed, front connectionFixed, front connectionFixed, front connection
Método de conexiónFront connection (rear connection/plug-in optional)Front connectionFront connectionFront connectionFront connection
Clase de protecciónIP20IP20IP20IP20IP20
Dimensiones (W*H*D)90mm*160mm*105mm90mm*155mm*100mm90mm*155mm*100mm90mm*160mm*105mm90mm*158mm*102mm
Vida mecánica20,000 ciclos20,000 ciclos20,000 ciclos20,000 ciclos15,000 ciclos
Vida eléctrica5,000 ciclos5,000 ciclos5,000 ciclos5,000 ciclos4,000 ciclos
Gama de precios (CNY)1,200-1,500 CNY900-1,100 CNY1,000-1,300 CNY1,100-1,400 CNY600-800 CNY
  1. Protection Function Comparison
Función de protecciónABB Formula A2Schneider EZDSchneider CVSSiemens 3VC2Chint NXM
Overload Long-Time Delay✓ No operation at 1.05×Ith, operation within 1 hour at 1.3×Ith✓ Same characteristics✓ Same characteristics✓ Same characteristics✓ Same characteristics
Short-Circuit Instantaneous✓ Instantaneous operation at 10×Ith (1500A)✓ Instantaneous operation at 10×Ith (1500A)✓ Instantaneous operation at 10×Ith (1500A)✓ Instantaneous operation at 10×Ith (1500A)✓ Instantaneous operation at 10×Ith (1500A)
Short-Circuit Short-Time DelayOptional electronic trip unit (PR211-LI)Optional electronic trip unitOptional electronic trip unitOptional electronic trip unitOptional electronic trip unit
Under-Voltage ProtectionOptional under-voltage release (UVR)Optional under-voltage releaseOptional under-voltage releaseOptional under-voltage releaseOptional under-voltage release
Viaje de derivaciónOptional shunt tripOptional shunt tripOptional shunt tripOptional shunt tripOptional shunt trip
Contactos auxiliares2NO+2NC optional2NO+2NC optional2NO+2NC optional2NO+2NC optional2NO+2NC optional
Alarm Contacts1NO optional1NO optional1NO optional1NO optional1NO optional
Función de aislamiento✓ Isolation capability when handle is in OFF position✓ Same characteristics✓ Same characteristics✓ Same characteristics✓ Same characteristics
Phase Unbalance Protection✓ Operates when three-phase current difference is excessive✓ Same characteristics✓ Same characteristics✓ Same characteristics✓ Same characteristics

III. Performance Characteristics and Application Scenario Comparison

Brand SeriesVentajas principalesEscenarios de aplicaciónReplacement Recommendation
ABB Formula A2• High mechanical strength, larga vida útil• Industrial automation systemsKey circuits requiring high reliability, can directly replace Siemens 3VC2 and Schneider CVS
• Strong accessory compatibility• Commercial building power distribution
• Reliable neutral line protection• Data center UPS output
Schneider EZD• Cost-effective, fácil instalación• Residential buildingsProjects with limited budget, can replace ABB A2 and Siemens 3VC2, 20% lower price
• Compact size, suitable for compact distribution cabinets• Small industrial equipment
• Lighting systems
Schneider CVS• Higher breaking capacity (36el)• Heavy-duty loadsOccasions with large short-circuit current, more suitable for industrial applications than EZD
• Good thermal stability• Distribution circuits close to transformers
• Suitable for frequent operation• Motor control with frequent start-stop
Siemens 3VC2• German manufacturing technology, high precision• Siemens automation system integrationFirst choice for users of Siemens ecosystem, can directly replace ABB A2
• Good compatibility with Siemens PLC• Precision equipment protection
• Complete diagnostic functions• Building automation
Chint NXM• Lowest price, extremely cost-effective• Residential buildingsCost-priority projects, can reduce procurement cost by 40%, performance meets basic requirements
• First choice for domestic replacement• Non-critical load circuits
• Perfect after-sales service network• Budget-sensitive projects
  1. Puntos clave de selección
  2. Breaking Capacity Matching

General distribution system: 25kA breaking capacity is sufficient (ABB A2C, Schneider EZD, Siemens 3VC2, Chint NXM)

Locations with large short-circuit current: Select 36kA breaking capacity (Schneider CVS) or 50kA breaking capacity (ABB A2N, Schneider NSX)

  1. System Earthing Configuration Adaptation

TN-C-S/TN-S system: 4-pole circuit breaker must be selected, all brands provide full-pole protection

TT system: 4P or 3P+N can be selected to ensure reliable neutral line disconnection

 

  1. Load Type Selection
Tipo de cargaRecommended Brand SeriesReason
Motor Load (≤75kW)ABB A2, Schneider CVSStrong overload capacity, adapts to motor starting impact
Lighting/Socket LoadSchneider EZD, Chint NXMAffordable price, meets basic protection requirements
Mixed LoadSiemens 3VC2, ABB A2Comprehensive protection characteristics, adapts to various loads
Critical EquipmentSchneider CVS, ABB A2Alta confiabilidad, larga vida útil
  1. Accessory Expansion Requirements

Mando a distancia: Select shunt trip + contactos auxiliares

Voltage Monitoring: Select under-voltage release

Monitoreo de estado: Select alarm contacts + communication module (electronic trip unit model)

  1. Resumen
MarcaComprehensive Score (10 points)Ventaja de precioPerformance AdvantageApplication Scenario Priority
ABB Formula A29★★★☆☆★★★★★Automatización Industrial > Edificios Comerciales > Residential Buildings
Schneider EZD8★★★★☆★★★☆☆Residential Buildings > Small Industry > Non-critical Loads
Schneider CVS8.5★★★☆☆★★★★☆Industrial Applications > Critical Loads > Edificios Comerciales
Siemens 3VC28.5★★★☆☆★★★★☆Siemens Ecosystem > Precision Equipment > Sistemas de automatización
Chint NXM7.5★★★★★★★★☆☆Residential Buildings > Budget-sensitive Projects > Non-critical Loads

Selection should be comprehensively considered based on four core factors: load type, short-circuit current size, system earthing configuration and budget to ensure the circuit breaker perfectly matches the system and provides the best protection effect. For most conventional applications, ABB AC250-4P-150A is an excellent choice balancing performance and price; Chint NXM is an ideal domestic replacement solution when budget is limited; Schneider CVS series is recommended for upgrade when short-circuit current is large.