ABB XT2N160 TMA 160 3p-F-F - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

ABB XT2N160 TMA 160 3p-F-F - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

cortacircuitos/

ABB XT2N160 TMA 160 3p-F-F

DimensionValor
Ancho90
Altura130
Profundidad82.5
Mounting hole spacing75
Terminal spacingEstándar
Peso1.574
Package size145*130*208
Package weight1.2

  • Detalles del producto

ABB XT2N160 TMA 160 3p F F

Nro. de orden: 1SDA061805R1 (1SDA067020R1)

Modelo completo: XT2N 160 TMA 160-1600 3p F F

Serie: Serie ABB Tmax XT Disyuntor de caja moldeada

  1. Core Parameters Summary
Categoría de parámetroDetailed SpecificationsNotas
Información básica• Frame size: XT2For low-voltage power distribution in industry and buildings
• Frame current: 160A
• Rated current In: 160A
• Poles: 3PAG
• Breaking capacity: Tipo N (36kA @ 415V AC)
• Rated operating voltage Ue: 690V y, 500En DC
• Standards: CEI 60947-2, ES 14048.2
Trip System• Trip type: TMA thermal-magnetic (sobrecarga + protección contra cortocircuitos)Not suitable for earth fault protection; additional accessories required
• Overload protection (Y): Ajustable, 160A
• Short-circuit protection (I3): Ajustable, 800~1600A
• Instantaneous short-circuit protection: Fixed at 10In (1600A)
• Protection curve: Cumple con IEC 60947-2
Montaje & Conexión• Mounting type: Fijado (F)Montaje en carril DIN estándar o con tornillos
• Connection: Conexión frontal (F)
• Operation: Operación de manija directa
• Dimensions: 90mm×130mm×82.5mm
• Weight: aprox. 1.574kilos
• Protection degree: IP20
Características eléctricas• Rated insulation voltage Ui: 800VSuitable for AC-1, AC-2, AC-3, AC-4 duties
• Rated impulse withstand voltage Uimp: 8kV
• Rated short-time withstand current Icw: 16kA/1s
• Rated frequency: 50/60Hz
• Wiring capacity: máximo. 95mm² copper, máximo. 70mm² aluminum
  1. Detailed Protection Characteristics

2.1 Protección contra sobrecarga (Thermal)

Característica: Inverse time curve per IEC 60947-2

Adjustable range: 160A (fixed)

Trip time:

1.05En: No trip for long duration

1.3En: Trip within ≤1 hour

6En: Trip within 2~10 seconds

2.2 Protección contra cortocircuitos (Magnetic)

Instantaneous trip: 800~1600A adjustable (I3)

Short-time delay: Not available (TMA has no short-time delay; TMD or electronic trip required)

Instantaneous short-circuit protection: Fixed at 10In (1600A), non-adjustable

  1. Dimensiones de montaje & Características físicas
DimensionValorUnit
Ancho90milímetros
Altura130milímetros
Profundidad82.5milímetros
Mounting hole spacing75milímetros
Terminal spacingEstándarmilímetros
Peso1.574kilos
Package size145*130*208milímetros
Package weight1.2kilos

Mounting Requirements:

35carril DIN estándar mm (EN 60715) recomendado

Temperatura ambiente: -25°C ~ +70°C

Altitud: ≤2000m (derating required above)

Protección: IP20 (frente); must be installed in enclosure with IP30 or higher

  1. Reemplazo & Extended Models in the Same Series

4.1 Direct Replacement Models

ModeloDifferenceSolicitud
XT2N160 TMA 160 3P F FIdentical specificationsReemplazo directo, no modification needed
XT2N160 TMA 160 3P P FPlug-in mounting (PAG)Frequent replacement or maintenance
XT2N160 TMA 160 3P F WRear connection (W.)Espacio limitado en el gabinete

4.2 Function-Extended Models

ModeloFunctional UpgradeNúmero de pedido.
XT2N160 Ekip LSI 160 3P F FElectronic trip, LSI protection1SDA067071R1
XT2N160 Ekip LSIG 160 3P F FElectronic trip, LSIG protection (including earth fault)1SDA067072R1
XT2N160 TMD 160 3P F FThermal-magnetic with short-time delay1SDA067035R1

4.3 Pole-Extended Models

4P version: XT2N160 TMA 160 4p F F (Nro. de orden: 1SDA061806R1 / 1SDA067041R1)

Neutral pole rated current: 50% o 100% of phase current optional

4.4 Cross-Brand Reference

Schneider: NSX160N TMD160 3P F

siemens: 3VT8116-1AA03-0AA0

chint: NM1-160S/3300 160A

  1. Accesorios recomendados
Accessory TypeModeloDescripción
Auxiliary contactXT2-AS111NO + 1CAROLINA DEL NORTE, for status indication
Alarm contactXT2-AL111NO + 1CAROLINA DEL NORTE, for fault alarm
Shunt tripXT2-SHTRemote tripping, AC/DC 220V
Liberación de subtensiónXT2-UVTProtección contra subtensión, CA 220 V
Rotary handleXT2-CRDoor-mounted operation, improved safety
Extended rotary handleXT2-CREFor deep panels
Tapa de terminalesXT2-TCProtect terminals, prevent electric shock
Label holderXT2-LBFor marking breaker parameters
  1. Aplicaciones & Notas de selección

6.1 Aplicaciones típicas

Industrial plants: Protección de motores (≤160A), distribution feeder protection

Commercial buildings: climatización, iluminación, pump control

Infraestructura: Small substations, centros de datos, PV systems

Otros: OEM equipment, maquinaria agrícola, marine systems

6.2 Guía de selección

RequirementRecomendadoNot Recommended
Protección de motores (with proper setting)motores pequeños (<10A); use MCB instead
Distribution protection (sub-circuits)Main incomer (use XT3/XT4 series)
Protección de falla a tierra (needs accessories) (choose Ekip LSIG)
Frequent operation (MCCB not suitable) (contactor + relé)
Función de aislamiento (CEI 60947-3)

6.3 Selection Cautions

  1. Ensure rated current In matches load
  2. Breaking capacity must meet system short-circuit current (norte: 36kA @ 415V)
  3. Montaje (fixed/plug-in) and connection (front/rear) must match panel design
  4. Auxiliaries, shunt/undervoltage trips ordered separately
  5. Not for DC short-circuit protection (use DC-rated model)
  6. Solución de problemas & Mantenimiento

7.1 Fallos comunes & Soluciones

SíntomaPosibles causasSoluciones
Tropiezos frecuentes1. Sobrecarga1. Check load
2. Short circuit2. Locate short circuit
3. Incorrect trip setting3. Reset settings
4. Temperatura ambiente alta4. Improve ventilation
no se puede cerrar1. No power to undervoltage trip1. Check control power
2. Shunt trip not reset2. Reset shunt trip
3. Mechanism fault3. Contact ABB service
4. Line fault4. Clear fault
No output after closing1. Main contacts damaged1. Inspect/replace contacts
2. Cableado suelto2. Apretar terminales
3. Trip unit fault3. Replace trip unit
Aux contact no signal1. Auxiliary contact defective1. Replace auxiliary contact
2. Wrong wiring2. Comprobar el cableado
3. Improper switching3. Adjust contact position

7.2 Recomendaciones de mantenimiento

Inspección: Every 6 months – check wiring and mechanism

Cleaning: Every 12 months – remove dust to maintain insulation

Operation test: Once per year – 3~5 manual ON/OFF cycles

Trip test: Una vez cada 2 years – simulate overload and short circuit

Service life: Típicamente 10 años, depending on duty and environment

  1. Realizar pedidos & Packaging

Standard package: 1 unit/box, including installation manual and certificate

Cantidad mínima de pedido: 1 unidad

Warranty: 18 months from commissioning, o 24 months from delivery (whichever comes first)

Código de pedido: 1SDA061805R1 (or 1SDA067020R1, varies by region)

Complete Model Guide for ABB Tmax XT2 Series (160A Frame)

Tamaño del marco: XT2 (160A)

Tensión nominal: 690V y, 500En DC

polacos: 3PAG / 4PAG

Breaking classes: norte(36el), S(50el), h(70el), l(100el)

  1. Model Naming Convention

XT2 [Breaking Class] [Marco actual] [Tipo de viaje] [Rango actual] [polacos] [Montaje] [Conexión]

Breaking class:

norte: 36kA @ 415V (estándar)

S: 50kA @ 415V (enhanced)

h: 70kA @ 415V (high performance)

l: 100kA @ 415V (ultimate)

Marco actual: 160 (fixed)

Trip type:

TMA: Termo-magnético (sobrecarga + instantáneo, no short-time delay)

TMD: Termo-magnético (sobrecarga + short-time delay + instantáneo)

Ekip LSI: Electrónico (sobrecarga + short-time delay + instantáneo)

Equipo LSIG: Electrónico (sobrecarga + short-time delay + instantáneo + falla a tierra)

Ekip I: Electrónico (instantaneous only)

Current range: p.ej., 160-1600 (TMA 160A)

polacos: 3PAG / 4PAG

Montaje: F (Fijado) / PAG (Plug-in)

Conexión: F (Front) / W. (Rear)

  1. XT2 Series Model List (by Breaking Class)

2.1 Standard Breaking (norte, 36el)

Model PrefixTipo de viajeModelo típicoRango actualSolicitud
XT2N160TMAXT2N160 TMA 160-1600 3P F F160AGeneral distribution, motores
TMDXT2N160 TMD 100-1000 4P F W100ASystems requiring short-time delay
Ekip LSIXT2N160 Ekip LSI R125 3P P F125AProtección electrónica, monitoreo remoto
Equipo LSIGXT2N160 Ekip LSIG R80 4P F F80AEarth fault protection required

Example Order No.: 1SDA061805R1 (XT2N160 TMA 160 3P F F)

2.2 Enhanced Breaking (S, 50el)

Model PrefixTipo de viajeModelo típicoRango actualSolicitud
XT2S160TMAXT2S160 TMA 63-630 3P F F63AIndustria, heavy-duty equipment
TMDXT2S160 TMD 40-400 4P P W40AFrequently started motors
Ekip LSIXT2S160 Ekip C Dip LSI R100 3P F F100AComplex commercial distribution
Equipo LSIGXT2S160 Ekip LSIG R50 4P F F50AData centers, medical facilities

Example Order No.: 1SDA067021R1 (XT2S160 TMA 160 3P F F)

2.3 High Performance Breaking (h, 70el)

Model PrefixTipo de viajeModelo típicoRango actualSolicitud
XT2H160TMAXT2H160 TMA 32-320 3P F F32AIndustrial systems with high short-circuit current
TMDXT2H160 TMD 3.2-32 4P F F3.2APrecision equipment, control circuits
Ekip LSIXT2H160 Ekip Dip LSI R63 3P P F63AGenerators, subestaciones
Equipo LSIGXT2H160 Ekip LSIG R25 4P F F25APV, renewable energy

Example Order No.: 1SDA067587R1 (XT2H160 TMD 3.2-32 3P F F)

2.4 Ultimate Breaking (l, 100el)

Model PrefixTipo de viajeModelo típicoRango actualSolicitud
XT2L160TMAXT2L160 TMA 100-1000 4P F F100AHeavy industry with very high fault level
TMDXT2L160 TMD 160-1600 3P F W160ALarge motor control centers
Ekip LSIXT2L160 Ekip LSI R160 3P P F160AMetallurgy, químico, hazardous areas
Equipo LSIGXT2L160 Ekip LSIG R125 4P F F125APetroquímico, minería

Example Order No.: 1SDA067667R1 (XT2L160 TMA 100-1000 4P F F)

  1. Trip Unit Comparison
Tipo de viajeProtecciónAdjustable ParametersTypical LoadPrice Level
TMASobrecarga + InstantáneoY, I3motores, distribución generalEconomía
TMDSobrecarga + Short-time + InstantáneoY, Isd, tsd, I3Transformers, condensadoresMedio
Ekip LSISobrecarga + Short-time + InstantáneoFull range, comunicaciónCritical distributionMedium-High
Equipo LSIGSobrecarga + Short-time + Instantáneo + Earth FaultFull range, comunicación, loggingCargas sensibles, safetyAlto
Ekip IInstantaneous onlyI3Short-circuit intensive devicesEconomía
  1. Special Models & Opciones

4.1 4P Neutral Configurations

Estándar: Neutral = 50% fase (distribución general)

Heavy: Neutral = 100% fase (non-linear loads: VFD, UPS)

Ejemplo: XT2N160 TMA 160 4P F F (100% neutral)

4.2 Plug-in Mounting (PAG)

Fast replacement, adecuado para equipos críticos

Ejemplo: XT2S160 TMD 80 3P P F

4.3 Rear Connection (W.)

Saves cabinet space, compact panels

Ejemplo: XT2H160 Ekip LSI R63 3P F W

4.4 Compatibilidad de accesorios (Full Series)

AccesorioModeloDescripción
Auxiliary contactXT2-AS111NO+1NC, status indication
Alarm contactXT2-AL111NO+1NC, fault alarm
Shunt tripXT2-SHTRemote tripping, AC/DC 220V
Liberación de subtensiónXT2-UVTProtección contra subtensión, CA 220 V
Rotary handleXT2-CRDoor operation, safety
  1. Quick Selection Table
SolicitudRecommended ClassTipo de viajepolacosMount/Conn
General industrialN/STMA/TMD3PAGF/F
Protección de motoresN/STMA3PAGF/F
Commercial lightingnorteTMA3P/4PF/F
Data centerH/LEquipo LSIG4PAGF/W
PV systemH/LEquipo LSIG4PAGF/F
Frequent maintenanceAnyAny3P/4PP/F
  1. Reemplazo & Upgrade Path

6.1 Same-Frame Upgrade

Capacidad de ruptura: XT2N → XT2S → XT2H → XT2L (dimensions unchanged)

Trip unit: TMA → TMD → Ekip LSI → Ekip LSIG

Mount/connection: F/F → P/F or F/W

6.2 Cross-Frame Upgrade

XT2 (160A) → XT3 (250A) → XT4 (250A enhanced) → XT5 (630A)

Note dimension and parameter changes

All XT2 series models comply with IEC 60947-2 y GB 14048.2.

Fixed dimensions: 90mm × 130mm × 82.5mm for easy system expansion and maintenance.

Anterior:

Próximo:

Deja una respuesta

Dejar un mensaje