The Chint CJ20-630A/380V AC contactor is an industrial control device specifically designed for high-power circuits. It is suitable for circuits with AC 50Hz, rated voltage of 380V, and rated current of 630A. Se utiliza principalmente para conectar y desconectar circuitos de forma remota., and can cooperate with thermal overload relays to realize motor protection.
- Core Technical Parameters and Structural Design
- Rendimiento eléctricoChint AC contactor
Corriente nominal: 630A (under AC-3 service category, it can control a three-phase squirrel-cage motor with a maximum power of approximately 315kW).
Vida eléctrica: 1 millones de veces (under AC-3 duty system), and the mechanical life reaches 6 millones de veces, reflecting high reliability.
Voltaje de la bobina: Supports AC 380V, 220V, 127V, etc., and DC 220V is optional, adapting to various control circuit requirements.
- Características estructuralesChint AC contactor coil NXC-25-220V
Arc Extinguishing System: Adopts a plastic grid arc extinguishing cover, which can quickly extinguish the arc generated when breaking large currents, ensuring the service life of contacts and breaking reliability.
Contact Material: Silver-based alloy contacts with excellent anti-welding performance, which can maintain stable conductive performance after long-term use.
Método de instalación: Supports screw fixing or 35mm standard rail mounting (for some models), with an inclination not exceeding ±5°, adapting to various industrial environments.
- Auxiliary FunctionsPrecio del disyuntor CHINT
Contactos auxiliares: Specifications of 250A and above are equipped with 4 normalmente abierto y 2 normally closed auxiliary contacts as standard, which can expand control logic (such as interlocking, signal feedback).
Energy-saving Module: Models CJ20-63 and above can be optionally equipped with AC silent energy-saving (j) or AC/DC universal energy-saving (JZ) modules to reduce energy consumption and noise.
- Application Scenarios and Installation Requirements
- Aplicaciones típicas
Industrial Drive: Motor control in large factories (como bombas de agua, fans, compresores), supporting frequent start-stop and forward-reverse operations.
Power Distribution System: Cooperates with circuit breakers and fuses to build highly reliable power distribution nodes.
Ambientes Especiales: Adapts to an ambient temperature of -5℃~+40℃, altitude ≤2000m, and relative humidity ≤90% (sin condensación), meeting the needs of most industrial scenarios.
- Especificaciones de instalación
Requisitos de cableado: The main contacts should use copper cables with a cross-sectional area of ≥185mm² or 50×5mm copper bars, and the tightening torque should reach 14N·m to ensure low-resistance connection.
Environmental Protection: Avoid installation in environments with strong vibration, flammable gases or corrosive media, and it is recommended to reserve sufficient heat dissipation space.
III. Troubleshooting and Maintenance Suggestions
- Problemas comunes y soluciones
Contactor Not Pulling In: Check if the coil voltage is normal (needs to reach 85%~110% of the rated value), clean the oil stains on the iron core pole surface, and eliminate mechanical jamming.
Contact Welding: If the load side is short-circuited or the operation frequency is too high, resulting in contact adhesion, the contacts need to be replaced and the circuit protection device should be checked.
Coil Overheating: Avoid voltage fluctuations exceeding ±10%, ensure the ambient temperature does not exceed +40℃, and replace the suitable coil if necessary.
- Maintenance Cycle
Daily Inspection: Clean the dust on the shell monthly, and check the contact wear (replace when the silver layer thickness is <0.5milímetros).
Annual Maintenance: Test the contact resistance (should be ≤50μΩ), verify the integrity of the arc extinguishing cover, and tighten all terminals.
- Certificación y Cumplimiento
This model has passed China Compulsory Certification (CCC certification), with the certificate number 2002010304009742, valid until November 8, 2020. It is recommended to confirm whether the current product still meets the latest industry standards (such as GB/T 14048.4-2010) through Chint’s official website or authorized dealers.
- Compra y soluciones alternativas
- Referencia de precio
The price of official channels (such as Chint Electric Mall) is about 5257 yuanes por unidad, and the quotation from third-party platforms (Whatsapp: 0086-13811255435) is about yuan per unit. Attention should be paid to configuration differences (such as the number of auxiliary contacts, whether it contains an energy-saving module).
- Modelos alternativos
Serie NC2: Chint’s new generation contactor (such as NC2-630) adopts a modular design, supports more flexible expansion of auxiliary functions, and the mechanical life is increased to 10 millones de veces, which can be used as an upgrade option.
- Safety Warnings
- Operation Specifications
Power must be cut off during installation and maintenance, and it should be operated by professional electricians to avoid the risk of electric shock.
It is prohibited to use in flammable and explosive environments to prevent explosions caused by arcs.
- Requisitos ambientales
Waste products must be disposed of according to electronic waste standards to avoid environmental pollution.
The core technical parameters of the Chint CJ20-630A/380V AC contactor are sorted out below, combining official data and industry standards:
- Parámetros de rendimiento eléctrico
| Nombre del parámetro | Value/Specification |
| Voltaje de trabajo nominal | CA 380V (compatible with 660V system, identified by auxiliary specification code 06) |
| Rated Working Current | 630A (under AC-3 service category, it can control a three-phase squirrel-cage motor with a maximum power of approximately 315kW) |
| Vida eléctrica | 1 millones de veces (AC-3 duty system) |
| Vida mecánica | 6 millones de veces (official standard value for specifications of 250A and above) |
| Coil Control Voltage | C.A.: 36V, 110V, 127V, 220V, 380V (50Hz) |
| corriente continua: 110V, 220V | |
| Coil Power | Starting power: 3578VA, holding power: 91.2VA (typical value, subject to product label) |
- Structure and Material Parameters
| Nombre del parámetro | Technical Details |
| Sistema de contacto | Main contacts: silver-based oxide material, double-break direct-acting design |
| Arc extinguishing system: plastic grid arc extinguishing cover, breaking capacity up to 100kA | |
| Contactos auxiliares | Standard configuration: 4 normalmente abierto y 2 normalmente cerrado (for 250A and above specifications) |
| Rated control capacity: AC-15 (380V/1.3A), DC-13 (220V/0.6A) | |
| Método de instalación | Screw fixing (compatible with 35mm standard rail mounting requires customization, not supported by conventional models by default) |
| Requisitos de cableado | Main contacts: use copper cables with cross-sectional area ≥185mm² or 50×5mm copper bars, tightening torque 14N·m |
| Auxiliary contacts: suitable for wires below 4mm² |
III. Environmental Adaptability Parameters
| Nombre del parámetro | Range/Conditions |
| Temperatura ambiente | -5℃~+40℃ (24-hour average does not exceed +35℃) |
| Altitud | ≤2000m (derating is required when exceeding) |
| Humidity Conditions | Relative humidity ≤90% (short-term condensation allowed at +25℃) |
| Grado de contaminación | Level 3 (suitable for industrial environments) |
| Installation Inclination | ≤±5° (vertical plane) |
- Shape and Physical Parameters
| Nombre del parámetro | Valor |
| Dimensiones generales | 210×287.5×244.5mm (length×width×height, Amax×Bmax×Cmax) |
| Peso | Approximately 12kg (including arc extinguishing cover and accessories, sujeto al producto real) |
| Protection Grade | IP20 (prevents intrusion of solid foreign objects larger than 12mm) |
- Key Performance Indicators
- Características de la acción
Pull-in voltage: 85%~110% of rated voltage<br>
Release voltage: 20%~75% of rated voltage (for ordinary type) or 10%~75% (for energy-saving type).
- Insulation Performance
Power frequency withstand voltage: 3000V/1min between main contacts, 2500V/1min between main contacts and coil.
- Typical Application Parameters
| Escenario de aplicación | Adapted Equipment Parameters |
| Control de motores | 380V/50Hz three-phase squirrel-cage motor: ≤315kW |
| 660V/50Hz motor: ≤560kW (personalización requerida) | |
| Power Distribution System | Cooperates with RT16-630 type fuses to achieve short-circuit protection (breaking capacity 120kA) |
| Energy-saving Module | Optional JZ type AC/DC universal energy-saving module, reducing coil energy consumption by more than 90% while eliminating AC noise |
VII. Usage Notes
- Especificaciones de cableado
The main circuit terminals must be tightened with a torque wrench according to 14N·m to avoid heating caused by virtual connection.
- Maintenance Cycle
Check the contact wear every quarter (replace when the silver layer thickness is <0.5milímetros), and verify the integrity of the arc extinguishing cover every year.
- Soluciones alternativas
Upgrade model: Chint NC2-630 contactor, with mechanical life increased to 10 millones de veces, supporting modular expansion.
contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares



















NH42-63-318x560.png)



