chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

Chint's NB1-63DC series DC circuit breakers - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

cortacircuitos/

Disyuntores de CC de la serie NB1-63DC de Chint

The following is a detailed technical analysis and application guide for Chint’s NB1-63DC series DC circuit breakers. It is compiled in combination with official materials and industry standards, covering core performance, selection key points, and typical scenarios: Core Technical Parameters Basic Specifications Item Parameter Rated Voltage DC 250V, 500V, 1000V (Breaking capacity varies with ...

  • Detalles del producto

The following is a detailed technical analysis and application guide for Disyuntores de CC de la serie NB1-63DC de Chint. It is compiled in combination with official materials and industry standards, covering core performance, selection key points, and typical scenarios:

  1. Parámetros técnicos básicos
  2. Especificaciones básicas

 

ArtículoParámetro
Tensión nominalDC 250V, 500V, 1000V (Breaking capacity varies with voltage level)
Corriente nominal1~63A (1P/2P/4P optional, Tripping curve: Type C 5-10In, Type D 10-14In)
Capacidad de rupturaDC 250V: 10el (Tipo C)
DC 500V: 8el (Tipo C)
DC 1000V: 6el (Tipo C)
Arc Extinguishing MethodAir arc extinguishing + magnetic blowout technology (Accelerates arc extinguishing through the magnetic field, suitable for DC highly inductive loads)
Características de disparoProtección contra sobrecarga: Inverse time-limit characteristic, in line with IEC 60947-2 estándar.
Protección contra cortocircuitos: Instantaneous tripping, Tipo C (5-10En), Type D (10-14En)
  1. Environmental and Mechanical Performance
ArtículoParámetro
Temperatura de funcionamiento-35℃~+70℃ (Wide temperature design, adaptable to harsh environments)
Nivel de protecciónIP20 (Front protection)
Método de instalación35mm standard rail installation (Supports DIN EN 50022)
Especificación de cableadoMain circuit: 2.5~16mm² single-core/stranded wire (M4 screw)
  1. Certificaciones y estándares

Certificaciones Internacionales: CCC, CE, CAO, TÜV, CB, SEMKO.

Standards Compliance: GB/T 14048.2, CEI 60947-2, RoHS environmental protection directive.

  1. Analysis of Key Features
  2. DC-specific Design

Arc Extinguishing Optimization: Adopts magnetic blowout arc extinguishing technology, which quickly stretches and cools the arc through the magnetic field to solve the problem of difficult arc extinguishing in DC circuits.

Polarity Protection: No built-in reverse connection protection, and anti-reverse connection function needs to be achieved through an external diode or MOS tube circuit.

  1. Intelligent Tripping and Protection

Protección contra sobrecarga: Bimetallic inverse time-limit tripping, the larger the current, cuanto más corto sea el tiempo de disparo (Por ejemplo: it will act within 2 minutes at 1.5 veces la corriente nominal).

Protección contra cortocircuitos: The electromagnetic trip unit responds instantaneously. Type C is suitable for conventional loads (such as LED lighting), and Type D is suitable for high-impact loads (como motores).

  1. Extended Functions

Contactos auxiliares: Supports external connection of OF (auxiliary contact) and SD (alarm contact) to achieve indication of opening and closing states or remote monitoring.

Accessory Compatibility: Can be equipped with shunt trip units (XF9), undervoltage trip units (MN), etc.. for extended functions.

III. Selection and Application Scenarios

 

  1. Guía de selección
  2. Coincidencia de voltaje: Select the corresponding model according to the system voltage (Por ejemplo, choose NB1-63DC/500V for DC 500V).
  3. Current Calculation:

Continuous Load: Rated current ≥ 1.2 times the load current.

Impact Load: Type D tripping curve, rated current ≥ (Load starting current / 10).

  1. Capacidad de ruptura: Ensure that the breaking capacity (uci) of the circuit breaker ≥ the system short-circuit current.
  2. Aplicaciones típicas
ScenarioModel RecommendationConfiguration Description
Photovoltaic String ProtectionNB1-63DC/500V C16ASuitable for 1500V photovoltaic systems (Needs to be derated for use), protects the string from overload and short-circuit
Energy Storage SystemNB1-63DC/1000V D25AHigh short-circuit breaking capacity, protects the battery pack and inverter interface
Industrial DC MotorNB1-63DC/250V D32AType D tripping curve, can withstand the starting impact current of the motor
Communication Base StationNB1-63DC/48V C6ALow voltage and high reliability, protects the power supply of communication equipment
  1. Instalación y mantenimiento
  2. Puntos clave de instalación

Especificación de cableado: The main circuit wiring needs to be tightened to a torque of 6N·m to avoid loose connection and heat generation.

Polarity Confirmation: Connect the positive and negative poles strictly according to the markings to avoid damage to the circuit breaker due to reverse connection.

Requisitos ambientales: Avoid using in environments with high humidity (>90%RH) or corrosive gases.

  1. Sugerencias de mantenimiento

Inspección periódica: Clean the contacts every quarter and check the flexibility of the tripping mechanism.

Life Management: Mechanical life ≥ 200,000 veces, electrical life ≥ 100,000 veces (DC-21A load).

Fault Troubleshooting: después de tropezar, confirm the cause of the fault, and manually disconnect the power supply before resetting.

  1. Comparison and Alternative Solutions
ModeloRango de voltajeCapacidad de rupturaCaracterísticas
NB1-63DCDC 250~1000V6~10kAMagnetic blowout arc extinguishing, supports wide temperature environment, suitable for highly inductive loads
NB1Z-63AC/DC 220~400V6el (C.A.)Suitable for both AC and DC, an economical choice with lower breaking capacity
NSX400N(Schneider)DC 1000V50elHigh short-circuit breaking capacity, suitable for large-scale energy storage systems, with a higher price
  1. Precauciones
  2. Derating for Use: When the ambient temperature exceeds 40℃, select the rated current according to derating 5% for every 10℃ increase.
  3. Short-circuit Withstand: The breaking capacity needs to match the system short-circuit current, otherwise it may lead to damage to the circuit breaker or the risk of fire.
  4. Modelos alternativos: If a higher breaking capacity is required, Chint’s NB1-63H (C.A.) or NB1-DC (DC-specific, breaking capacity 15kA) se puede seleccionar.

For detailed technical manuals or customized solutions, puedes visitar Chint’s official web siteor contact local technical support.