EBS203C-200A-3P is a 3-pole, 200A rated earth-leakage disyuntor de caja moldeada (MCCB/ELCB) manufactured by LS Electric (formerly LS Industrial Systems / LG Industrial Systems). It provides overcurrent, short-circuit and earth-leakage protection for three-phase electrical circuits.
📌 Model Explanation
EBS203C: EBS series earth-leakage MCCB; 200 = frame size (AF), 3 = number of poles (3PAG), C = thermal-magnetic trip type (TM).
200A: Corriente operativa nominal 200 amperes.
3PAG: 3 polos, suitable for three-phase three-wire systems.
⚙️ Key Specifications
| Artículo | Especificación |
| Tamaño del marco (AF) | 200AF~399AF |
| Rated short‑circuit breaking capacity (uci) | 85kA at AC220V; 37kA at AC400V |
| Tensión nominal | AC220/460V |
| Protection functions | Sobrecarga, short‑circuit, fuga a tierra (100/200/500mA optional) |
| Trip type | Thermal‑magnetic trip (TM), instantaneous trip rating 12×In |
| Dimensiones (Alto×Ancho×Profundidad) | 165×105×87mm |
| Peso | Aprox.. 1.2kilos |
| Certificaciones | CE, CCC |
🛠️ Applications & Compatibilidad
Aplicaciones típicas: Distribución de energía industrial, production line equipment, power and lighting circuits, suitable for three-phase applications requiring reliable earth-leakage and short-circuit protection.
Recommendation: Can be used with Meta-MEC series products for selective protection and coordination to improve system reliability.
🔄 Equivalent & Series Models
Same series: EBS203C-100A/125A/150A/175A, EBS204C (4-polo), etc..
Alternative references: ABB Tmax series, Schneider NSX series, Chint NM8L series and other equivalent earth-leakage MCCBs. Breaking capacity and mounting dimensions must be matched.
📦 Supply & Procurement
Marca: LS Electrico (LSIS), originally manufactured in South Korea.
Purchasing channels: Authorized LS Electric distributors in China, industrial platform www.bestcontactor.com. Typical price is around one thousand RMB; negotiable for bulk orders.
The core difference between EBS203C-200A-3P and EBS203C-200A-4P (modelo estándar: EBS204C-200A) lies in the number of poles and the control method of the neutral (norte) conductor, which directly affects wiring, protection scope and application scenarios.
- Structural Differences
EBS203C-200A-3P (3-polo)
Structure: 3 line/incoming terminals, controlling only L1, L2, L3 (three-phase live conductors).
Neutral (norte): Does not pass through the breaker; directly connected.
Protección: Provides overload, short-circuit and earth-leakage protection only for three-phase live conductors.
EBS204C-200A-4P (4-polo)
Structure: 4 line/incoming terminals, controlling L1, L2, L3 + norte (three-phase live conductors + neutral).
Neutral (norte): Passes through the breaker and switches simultaneously with phase conductors.
Protección: Protects three-phase live conductors + neutral and can disconnect a faulty neutral line.
- Key Parameter Comparison
| Artículo | EBS203C‑200A‑3P | EBS204C‑200A‑4P |
| Marco / Actual | 200AF, 200A, thermal‑magnetic type C | Idéntico |
| Capacidad de ruptura | 37kA at AC400V; 85kA at AC220V | Idéntico |
| Protection functions | Sobrecarga, short‑circuit, fuga a tierra | Idéntico |
| polacos | 3PAG (3‑pole) | 4PAG (4‑pole) |
| Neutral (norte) | Bypasses the breaker | Switched with phases |
| Ancho | Narrower (aprox. 105milímetros) | Wider (aprox. 140milímetros) |
| Applicable system | Three‑phase three‑wire (IT, TN‑C without PEN) | Three‑phase four‑wire (TN‑S, TN‑C‑S, TT) |
III. Functional & Safety Differences
- Switching range
3PAG: Switches phases only. Neutral remains live, posing electric shock risk during maintenance.
4PAG: Switches both phases and neutral. Fully isolates power, safer and compliant with standards.
- Earth-leakage protection effectiveness
3PAG: Only detects three-phase current imbalance. Cannot protect against neutral faults (p.ej., neutral-to-earth short circuit).
4PAG: Monitors total current of four poles (L1-L2-L3-N), trips on neutral leakage for complete protection.
- System compatibility
3PAG: Suitable for pure three-phase loads (motores, zapatillas) with no single-phase loads and no neutral in the panel.
4PAG: Suitable for mixed three-phase + single-phase systems (comercial, industrial, distribución del edificio); neutral disconnection required for safety.
- Guía de selección
Choose 3P (EBS203C):
Loads are pure three-phase motors, compresores, calentadores, etc., with no 220V single-phase circuits.
Neutral in the distribution box does not pass through this breaker; space is limited.
Choose 4P (EBS204C):
System is TN-S / TN-C-S (separate N and PE conductors).
Circuit supplies single-phase loads (iluminación, enchufes, control circuits); neutral must be switched.
Required by safety standards (maintenance, earth-leakage protection, earthing systems).
Resumen
3P = space-saving, cost-effective → dedicated for three-phase power
4P = safer, more complete → required for mixed power distribution
LS Electric EBS Series Earth-Leakage MCCBs (ELCB): Model List & Cross-Brand Cross-Reference
- EBS Series Model System & Full List
Core features of EBS series: Earth-leakage molded case circuit breakers on LS Electric’s (formerly LS / LG Industrial Systems) Metasol platform, with built-in earth-leakage protection modules, proporcionando triple protección contra sobrecarga, short-circuit and residual current (fuga a tierra) for low-voltage distribution systems.
- Model Naming Convention
EBS □□□ – □□□A – □P
EBS: código de serie (earth-leakage MCCB)
1primer dígito: Tamaño del marco (5=50AF, 10=100AF, 20=200AF, 40=400AF)
2segundo dígito: Number of poles (3=3P, 4=4P)
3rd letter: Clase de capacidad de ruptura (C=standard, S=high)
□□□A: Corriente nominal (En)
□P: Number of poles (3P/4P, consistent with 2nd digit)
- Complete Model List by Frame Size
1) 50AF Frame (EBS53C / EBS54C)
| polacos | Corriente nominal | Modelo completo | Capacidad de ruptura (AC400V) |
| 3PAG | 10A/16A/20A/25A/32A/40A/50A | EBS53C‑10A~50A | 18el |
| 4PAG | 10A/16A/20A/25A/32A/40A/50A | EBS54C‑10A~50A | 18el |
2) 100AF Frame (EBS103C / EBS104C)
| polacos | Corriente nominal | Modelo completo | Capacidad de ruptura (AC400V) |
| 3PAG | 63A/75A/100A | EBS103C‑63A/75A/100A | 37el |
| 4PAG | 63A/75A/100A | EBS104C‑63A/75A/100A | 37el |
3) 200AF Frame (EBS203C / EBS204C)
| polacos | Corriente nominal | Modelo completo | Capacidad de ruptura (AC400V) |
| 3PAG | 125A/150A/175A/200A/225A/250A | EBS203C‑125A~250A | 37el |
| 4PAG | 125A/150A/175A/200A/225A/250A | EBS204C‑125A~250A | 37el |
4) 400AF Frame (EBS403C / EBS404C)
| polacos | Corriente nominal | Modelo completo | Capacidad de ruptura (AC400V) |
| 3PAG | 250A/300A/350A/400A | EBS403C‑250A~400A | 50el |
| 4PAG | 250A/300A/350A/400A | EBS404C‑250A~400A | 50el |
- Earth-Leakage Parameters (Whole Series)
Corriente de funcionamiento residual (IΔn): 30mA/100mA/300mA/500mA optional (default 30mA for personal protection)
tiempo de funcionamiento: ≤0.3s (IΔn=30mA), ≤0,1 s (IΔn≥100mA)
Protection type: Tipo A (C.A. + pulsating DC leakage), suitable for modern electronic loads
- Cross-Brand Equivalent Table for EBS Series
Below are equivalent models from major brands with matching core parameters (frame, corriente nominal, polos, capacidad de ruptura) for replacement reference.
| LS EBS Model | ABB Tmax XT | Schneider NSX | Chint NM8L | Delixi CDM1L |
| EBS53C‑50A‑3P | XT1N160 TMD50 3P RCCB | NSX100N TM50D 3P Vigi | NM8L‑100S/3300 50A | CDM1L‑100C/3300 50A |
| EBS103C‑100A‑3P | XT1N160 TMD100 3P RCCB | NSX100N TM100D 3P Vigi | NM8L‑100S/3300 100A | CDM1L‑100C/3300 100A |
| EBS203C‑200A‑3P | XT2N250 TMD200 3P RCCB | NSX250N TM200D 3P Vigi | NM8L‑250S/3300 200A | CDM1L‑250C/3300 200A |
| EBS204C‑200A‑4P | XT2N250 TMD200 4P RCCB | NSX250N TM200D 4P Vigi | NM8L‑250S/4300 200A | CDM1L‑250C/4300 200A |
| EBS403C‑400A‑3P | XT4N630 TMD400 3P RCCB | NSX630N TM400D 3P Vigi | NM8L‑630S/3300 400A | CDM1L‑630C/3300 400A |
Notas clave para el reemplazo
- Breaking capacity matching: Select alternatives with breaking capacity ≥ original EBS model to ensure short-circuit protection reliability.
- Earth-leakage module compatibility:
ABB requires RC221/RC222 earth-leakage accessories
Schneider requires Vigi modules (built-in / add-on)
Domestic NM8L/CDM1L have built-in earth-leakage modules, no extra parts needed
- Mounting dimension check: Width may vary between brands (p.ej., EBS203C-200A-3P: 105milímetros; Schneider NSX250: 108milímetros), affecting panel layout.
- Wiring type: Ensure replacement supports original mounting (fixed / complemento) and connection (frente / cableado trasero).
III. Diferencias clave: EBS203C-200A-3P vs EBS204C-200A-4P
| Artículo | EBS203C‑200A‑3P (3‑pole) | EBS204C‑200A‑4P (4‑pole) |
| polacos & Terminales | 3 main terminals (L1/L2/L3) | 4 main terminals (L1/L2/L3/N) |
| Neutral control | Neutral bypasses breaker | Neutral switched with phases |
| Protection scope | Sobrecarga, short‑circuit, leakage on phases only | Full protection on phases + neutral (including neutral leakage) |
| Ancho | 105milímetros | 140milímetros |
| Applicable system | 3‑phase 3‑wire (IT, TN‑C without PEN) | 3‑phase 4‑wire (TN‑S, TN‑C‑S, TT) |
| Safety level | Phases switched only; extra isolation needed | Full isolation; mayor seguridad |
- Selección & Procurement Advice
- Selección de polos
Pure three-phase power loads (motores, compresores) → choose 3P (EBS203C)
Mixed three-phase + single-phase loads (iluminación, enchufes) → choose 4P (EBS204C) to meet safety standards
- Earth-leakage current selection
Personal protection (circuitos de enchufe) → IΔn = 30mA
Electrical fire prevention (power/lighting mains) → IΔn = 100mA / 300mamá
- Purchasing channels
Authorized domestic distributors, industrial e-commerce platform www.bestcontactor.com
Regular stock models: EBS53C-50A, EBS103C-100A, EBS203C-200A, EBS403C-400A, etc..
contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares























NH42-63-318x560.png)