ArtículoSpecification Parameter
Brand and SeriesSchneider Acti9 Series
Tipo de producto1-pole Disconnector (speculative)
Voltaje de trabajo nominal120V y (North American voltage class)
Rated Working Current100A
Número de polo1-polo
Función principalCircuit isolation, no-load switching
Escenario de aplicaciónPower isolation and maintenance power-off in single-phase 120V power distribution systems in North America

  • Detalles del producto

Model A9I48191V120H1P-100A

Model A9I48191V120H1P-100A is the complete order number of a low-voltage electrical product under the Acti9 Series of Schneider Electric. The meaning of each segment of the code and the corresponding product attributes can be explained as follows:

  1. Model Segment Analysis
  2. A9: Represents the major product series, namely Schneider’s Acti9 Series. This series is a standardized low-voltage component series launched by Schneider for terminal power distribution, covering miniature circuit breakers, dispositivos de corriente residual, disconnectors, and other products.
  3. I48: Represents the product type sub-code. In combination with the naming rules of the Acti9 Series, this code usually refers to disconnectors or fuse-disconnectors, which are mainly designed for no-load switching of circuits and power isolation.
  4. 191: Represents the structural characteristics and accessory configuration code. Different number combinations correspond to different installation methods (p.ej., DIN rail mounting), operation methods (p.ej., handle operation), or auxiliary contact configurations.
  5. V120: Represents the rated working voltage parameter of the product. Here, `V120` indicates that the rated working voltage of the product is suitable for 120V AC circuits. It should be noted that this voltage class is common in the North American market and is incompatible with the mainstream 220V/380V voltage system in China.
  6. H1P: Represents the pole number and installation specification of the product. `H1P` means a 1-pole product, suitable for the isolation requirements of single-phase circuits.
  7. 100A: Represents the rated working current of the product, es decir., the maximum current that the component can carry stably for a long time is 100A.
  8. Summary of Core Product Attributes
ArtículoSpecification Parameter
Brand and SeriesSchneider Acti9 Series
Tipo de producto1-pole Disconnector (speculative)
Voltaje de trabajo nominal120V y (North American voltage class)
Rated Working Current100A
Número de polo1-polo
Función principalCircuit isolation, no-load switching
Escenario de aplicaciónPower isolation and maintenance power-off in single-phase 120V power distribution systems in North America
  1. Key Precautions
  2. Voltage Compatibility: The rated voltage of this product is 120V AC. It is strictly prohibited to use it directly in domestic 220V AC circuits, de lo contrario, it may cause safety accidents such as component burnout and insulation breakdown.
  3. Functional Positioning: Disconnectors do not have short-circuit protection or overload protection functions and are only used for circuit isolation. They must be used in conjunction with protective components such as circuit breakers.
  4. Model Verification: To confirm accurate product drawings, installation dimensions, and technical manuals, you can enter the complete order number through Schneider’s official product selection tool or technical support hotline for inquiry.

Domestic Voltage-Adaptable Model Comparison Table for Schneider Acti9 Series 100A Disconnectors

The following is a complete comparison table of domestic adaptable models corresponding to the North American model A9I48191V120H1P-100A and models with different pole numbers of the same specification. These models are suitable for the mainstream 230/400V AC voltage system in China and meet the isolation requirements of single-phase/three-phase power distribution systems.

  1. Core Model Correspondence
North American Original ModelDomestic Adaptable ModelSerie de productosNúmero de poloTensión nominalCorriente nominalTipo de producto
A9I48191V120H1P-100AA9S70690 (iSW Series) / A9S66191Acti91PAG230/400V y100AMiniature Disconnector
A9I48191V120H1P-100AA9S71690 (iSW Series)Acti91PAG230/400V y100ADisconnector with Auxiliary Contacts
A9I48191V120H1P-100AiINT125 1P 100AActi91PAG230/400V y100ATerminal Disconnector
  1. Complete Table of Domestic Adaptable Models with Different Pole Numbers of the Same Specification
Número de poloDomestic Standard ModelSerie de productosTensión nominalCorriente nominalModule WidthCore FeaturesEscenarios de aplicación típicos
1PAGA9S70690 (iSW)Acti9230/400V y100A2 módulos (18milímetros)Basic disconnector without auxiliary contactsIsolation of single-phase circuits, such as residential incoming lines and power isolation of small equipment
1PAGA9S66191 (iSW)Acti9230/400V y100A2 módulos (18milímetros)Standard disconnector with red operating handleSingle-phase power distribution in commercial buildings, maintenance isolation
1PAGiINT125 1P 100AActi9230/400V y100A2 módulos (18milímetros)Terminal-specific with optimized operating mechanismDC-side isolation of photovoltaic systems, front-end of small UPS
2PAGA9S70790 (iSW)Acti9230/400V y100A4 módulos (36milímetros)2-pole interlock, simultaneous isolation of live wire and neutral wireSingle-phase 2-pole circuits, such as high-power household appliances like air conditioners and water heaters
2PAGA9S66291 (iSW)Acti9230/400V y100A4 módulos (36milímetros)Standard 2-pole with red handlePower isolation of commercial kitchen equipment and small air compressors
3PAGA9S70890 (iSW)Acti9400V y100A6 módulos (54milímetros)3-pole interlock, three-phase isolationFront-end of three-phase equipment such as motors, bombas de agua, y fans
3PAGA9S66391 (iSW)Acti9400V y100A6 módulos (54milímetros)Standard 3-pole with high short-circuit withstand capacityIndustrial automation equipment, main switch of small power distribution cabinets
4PAGA9S70990 (iSW)Acti9400V y100A8 módulos (72milímetros)4-pole interlock, three-phase + neutral wire isolationUPS input/output in data centers, isolation of medical equipment
4PAGA9S66491 (iSW)Acti9400V y100A8 módulos (72milímetros)Standard 4-pole with locking deviceThree-phase power distribution in special industries such as chemical and metallurgical industries
  1. Key Adaptation Instructions
  2. Voltage Compatibility: All domestic models are suitable for 230/400V AC (50/60Hz), fully compatible with the domestic power grid. It is strictly prohibited to directly use North American 120V models in domestic 220V/380V systems.
  3. Functional Consistency: All domestic models retain the core functions of disconnectors—no-load circuit switching and power isolation. They do not have short-circuit or overload protection capabilities and must be used in conjunction with circuit breakers.
  4. Installation Compatibility: All models adopt 35mm DIN standard rail mounting, consistent with the installation method of the original North American model, enabling direct replacement and installation.
  5. Recomendaciones de selección:

For single-phase circuits, prioritize 1P/2P models.

For three-phase power circuits, prioritize 3P models.

For critical loads requiring simultaneous neutral wire isolation (such as medical equipment and data centers), select 4P models.

For applications requiring remote status monitoring, select models with auxiliary contacts such as A9S71690.

  1. Supplementary Information
ArtículoDetailed Description
Certification StandardCumple con IEC 60947-3 y GB 14048.3 estándares, holding domestic CCC certification
Operating LifeMechanical life ≥ 10,000 veces; Electrical life ≥ 1,000 veces (no-load operation)
TerminalSuitable for 16~25mm² copper conductors, recommended torque: 8~10N·m
Clase de protecciónIP20, suitable for installation inside power distribution cabinets