Schneider EZD160A Moulded Case Circuit Breaker - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

Schneider EZD160A Moulded Case Circuit Breaker - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

cortacircuitos/

Schneider EZD160A Moulded Case Circuit Breaker

Schneider EZD160A is a 160A frame moulded case circuit breaker (MCCB) from the EZD series, designed for secondary power distribution, construcción civil, and electromechanical markets. It features high cost-performance, fácil instalación, y rendimiento de seguridad confiable, used for power distribution and protecting circuits and equipment against overload and short-circuit faults. 1 Complete Model Definition Standard model ...

  • Detalles del producto

Schneider EZD160A is a 160A frame moulded case circuit breaker (MCCB) from the EZD series, designed for secondary power distribution, construcción civil, and electromechanical markets. It features high cost-performance, fácil instalación, y rendimiento de seguridad confiable, used for power distribution and protecting circuits and equipment against overload and short-circuit faults.

1 Complete Model Definition

Standard model format: EZD160[Capacidad de ruptura][polacos][Corriente nominal][Accesorio]

ParteSignificadoAvailable Values
EZD160Frame size 160AEZD100/160/250/400/630
Capacidad de rupturaE=25kA, M=36kA, S=50kAE/M/S
polacos3P/4P3月4日
Corriente nominal63A~160A63/80/100/125/160
AccesorioN=Standard, L=Earth leakage protection, EL=Electronic earth leakageN/L/EL

Ejemplo: EZD160E3160N = 160A frame, 25kA capacidad de corte, 3 polos, 160Una corriente nominal, tipo estándar

2 Parámetros técnicos clave

ParámetroEspecificaciónObservaciones
Tensión nominal400V/690VThree‑phase AC
Corriente nominal (En)160AThermal‑magnetic trip unit (TMD)
Capacidad de ruptura (uci)25el(mi)/36el(METRO)/50el(S)@415V
Trip typeLI (Long‑time + Instantáneo)Standard configuration for distribution protection
polacos3P/4P3P for three‑phase circuits, 4P includes neutral protection
Mounting typeFijado / Plug‑inSupports horizontal, vertical, and side mounting
Connection typeFront / Rear / Plug‑inFlexible for various switchgear designs
Operation typeManual / Motor‑operated (opcional)Motor mechanism enables remote control
Protección de ingresoIP30Complies with IEC 60947‑2

3 Características del producto & Ventajas

  1. Alto costo-rendimiento: Ideal choice for secondary power distribution, reliable performance, affordable price
  2. Easy installation: Tamaño compacto, saves 30% espacio de instalación, supports multiple mounting orientations
  3. Protección integral: Thermal-magnetic trip unit provides dual overload and short-circuit protection
  4. Rich accessories: Compatible with earth leakage modules (Vigí), motor operators, etc..
  5. Seguro y confiable: Complies with IEC/GB standards and passes strict quality certification

4 Aplicaciones

  1. Commercial buildings: Secondary power distribution in offices, centros comerciales, hoteles
  2. Industrial facilities: Motor protection and power distribution in small factories, production lines
  3. Residential buildings: Main and sub-distribution boards in high-rise residential buildings
  4. Infraestructura: Auxiliary power distribution in hospitals, schools, centros de datos
  5. PV systems: Used as protection switch at inverter output

5 Complete Model List (160A Frame)

Capacidad de ruptura3P Model4P ModelEarth Leakage Model
mi (25el)EZD160E3160NEZD160E4160NEZD160E3160ELN (EZD160E4160ELN)
METRO (36el)EZD160M3160NEZD160M4160NEZD160M3160ELN (EZD160M4160ELN)
S (50el)EZD160S3160NEZD160S4160NEZD160S3160ELN (EZD160S4160ELN)

6 Alternativas

6.1 Upgraded Alternatives within Schneider

CVS Series: Upgraded version of EZD, mayor capacidad de rotura (up to 100kA), improved intelligence

NSX Series: Premium MCCB with optional electronic trip units, supports power monitoring and communication

6.2 Chinese Domestic Brand Alternatives

MarcaEquivalent ModelVentajas
chintNM1‑160S/3300Lower cost, short delivery time
DeliciosoCDM3‑160S/3300Similar performance, complete after‑sales service
Interruptor ChangshuCM3‑160S/3300High breaking capacity, adecuado para entornos industriales

7 Selection Guidelines

  1. Breaking capacity selection: Choose E/M/S rating based on system short-circuit current calculation
  2. Selección de polos: 4P for mixed single-phase + three-phase systems; 3P for pure three-phase power systems
  3. Accessory configuration: Earth leakage module required in humid environments or where high personal safety is required
  4. Mounting type: Plug-in recommended for applications requiring frequent maintenance
  5. Trip adjustment: Long-time setting (Y) adjustable from 0.8 to 1×In to suit different load characteristics

Complete Model List of Schneider EZD Series MCCBs

Schneider EZD series MCCBs target secondary power distribution, construcción civil, and electromechanical markets. They are available in five frame sizes: 100A/160A/250A/400A/630A, three breaking capacities: 25el(mi)/36el(METRO)/50el(S), two pole configurations: 3P/4P, and two basic types: standard and earth leakage (Vigi EZD), with rated current ranging from 15A to 630A.

1 Model Naming Rule

Standard model format: EZD[Frame Size][Capacidad de ruptura][polacos][Corriente nominal][Accesorio]

ParteSignificadoAvailable Values
EZDSerie de productosEZD
Tamaño del marcoMaximum rated current100/160/250/400/630
Capacidad de rupturaShort‑circuit breaking capacityE=25kA, M=36kA, S=50kA
polacos3‑pole / 4‑pole3-4
Corriente nominalTrip unit rated current15/20/25/30/40/50/63/80/100/125/160

/200/225/250/315/320/400/500/630

AccesorioEstándar / Earth leakageN=Standard, ELN=Electronic earth leakage

2 Complete Model List

2.1 EZD100 (100A Frame)

Capacidad de rupturapolacosCorriente nominalStandard ModelEarth Leakage Model
mi (25el)3PAG15A~100AEZD100E3015N ~ EZD100E3100NEZD100E3015ELN ~ EZD100E3100ELN
4PAG15A~100AEZD100E4015N ~ EZD100E4100NEZD100E4015ELN ~ EZD100E4100ELN
METRO (36el)3PAG15A~100AEZD100M3015N ~ EZD100M3100NEZD100M3015ELN ~ EZD100M3100ELN
4PAG15A~100AEZD100M4015N ~ EZD100M4100NEZD100M4015ELN ~ EZD100M4100ELN
S (50el)3PAG15A~100AEZD100S3015N ~ EZD100S3100NEZD100S3015ELN ~ EZD100S3100ELN
4PAG15A~100AEZD100S4015N ~ EZD100S4100NEZD100S4015ELN ~ EZD100S4100ELN

2.2 EZD160 (160A Frame)

Capacidad de rupturapolacosCorriente nominalStandard ModelEarth Leakage Model
mi (25el)3PAG63A~160AEZD160E3063N ~ EZD160E3160NEZD160E3063ELN ~ EZD160E3160ELN
4PAG63A~160AEZD160E4063N ~ EZD160E4160NEZD160E4063ELN ~ EZD160E4160ELN
METRO (36el)3PAG63A~160AEZD160M3063N ~ EZD160M3160NEZD160M3063ELN ~ EZD160M3160ELN
4PAG63A~160AEZD160M4063N ~ EZD160M4160NEZD160M4063ELN ~ EZD160M4160ELN
S (50el)3PAG63A~160AEZD160S3063N ~ EZD160S3160NEZD160S3063ELN ~ EZD160S3160ELN
4PAG63A~160AEZD160S4063N ~ EZD160S4160NEZD160S4063ELN ~ EZD160S4160ELN

2.3 EZD250 (250A Frame)

Capacidad de rupturapolacosCorriente nominalStandard ModelEarth Leakage Model
mi (25el)3PAG100A~250AEZD250E3100N ~ EZD250E3250NEZD250E3100ELN ~ EZD250E3250ELN
4PAG100A~250AEZD250E4100N ~ EZD250E4250NEZD250E4100ELN ~ EZD250E4250ELN
METRO (36el)3PAG100A~250AEZD250M3100N ~ EZD250M3250NEZD250M3100ELN ~ EZD250M3250ELN
4PAG100A~250AEZD250M4100N ~ EZD250M4250NEZD250M4100ELN ~ EZD250M4250ELN
S (50el)3PAG100A~250AEZD250S3100N ~ EZD250S3250NEZD250S3100ELN ~ EZD250S3250ELN
4PAG100A~250AEZD250S4100N ~ EZD250S4250NEZD250S4100ELN ~ EZD250S4250ELN

2.4 EZD400 (400A Frame)

Capacidad de rupturapolacosCorriente nominalStandard ModelEarth Leakage Model
mi (25el)3PAG200A~400AEZD400E3200N ~ EZD400E3400NEZD400E3200ELN ~ EZD400E3400ELN
4PAG200A~400AEZD400E4200N ~ EZD400E4400NEZD400E4200ELN ~ EZD400E4400ELN
METRO (36el)3PAG200A~400AEZD400M3200N ~ EZD400M3400NEZD400M3200ELN ~ EZD400M3400ELN
4PAG200A~400AEZD400M4200N ~ EZD400M4400NEZD400M4200ELN ~ EZD400M4400ELN
S (50el)3PAG200A~400AEZD400S3200N ~ EZD400S3400NEZD400S3200ELN ~ EZD400S3400ELN
4PAG200A~400AEZD400S4200N ~ EZD400S4400NEZD400S4200ELN ~ EZD400S4400ELN

2.5 EZD630 (630A Frame)

Capacidad de rupturapolacosCorriente nominalStandard ModelEarth Leakage Model
mi (25el)3PAG400~630AEZD630E3400N ~ EZD630E3630NEZD630E3400ELN ~ EZD630E3630ELN
4PAG400~630AEZD630E4400N ~ EZD630E4630NEZD630E4400ELN ~ EZD630E4630ELN
METRO (36el)3PAG400~630AEZD630M3400N ~ EZD630M3630NEZD630M3400ELN ~ EZD630M3630ELN
4PAG400~630AEZD630M4400N ~ EZD630M4630NEZD630M4400ELN ~ EZD630M4630ELN
S (50el)3PAG400~630AEZD630S3400N ~ EZD630S3630NEZD630S3400ELN ~ EZD630S3630ELN
4PAG400~630AEZD630S4400N ~ EZD630S4630NEZD630S4400ELN ~ EZD630S4630ELN

3 Notas clave

  1. Rated current ratings: Standard current steps for each frame:

EZD100: 15/20/25/30/40/50/63/80/100A

EZD160: 63/80/100/125/160A

EZD250: 100/125/160/200/225/250A

EZD400: 200/225/250/315/320/400A

EZD630: 400/500/630A

  1. Trip type: Standard configuration is thermal-magnetic trip (TMD) providing LI (long-time + instantáneo) protection for distribution applications.
  2. Earth leakage protection: Vigi EZD series features electronic earth leakage protection (ELN), with optional trip or alarm without trip modes, suitable for 3P/3d (3-pole protection) and 4P/3d (4-pole with neutral, 3-pole protection) configurations.
  3. Montaje: Supports fixed and plug-in installation; wiring can be front/rear/plug-in.
  4. Protección de ingreso: IP30, Cumple con IEC 60947-2.

Complete Model List for the Full Schneider EZD Series

(Directly usable for selection and quotation)

Organized by frame → breaking capacity → poles → rated current → standard / earth leakage type.

1 EZD100 Frame (100A)

Corriente nominal: 15, 20, 25, 30, 40, 50, 63, 80, 100A

1.1 Type E (25el)

3P Standard: EZD100E3015N, EZD100E3020N, EZD100E3025N, EZD100E3030N, EZD100E3040N, EZD100E3050N, EZD100E3063N, EZD100E3080N, EZD100E3100N

3P Earth leakage: EZD100E3015ELN, EZD100E3020ELN, EZD100E3025ELN, EZD100E3030ELN, EZD100E3040ELN, EZD100E3050ELN, EZD100E3063ELN, EZD100E3080ELN, EZD100E3100ELN

4P Standard: EZD100E4015N, EZD100E4020N, EZD100E4025N, EZD100E4030N, EZD100E4040N, EZD100E4050N, EZD100E4063N, EZD100E4080N, EZD100E4100N

4P Earth leakage: EZD100E4015ELN, EZD100E4020ELN, EZD100E4025ELN, EZD100E4030ELN, EZD100E4040ELN, EZD100E4050ELN, EZD100E4063ELN, EZD100E4080ELN, EZD100E4100ELN

1.2 Type M (36el)

3P Standard: EZD100M3015N ~ EZD100M3100N

3P Earth leakage: EZD100M3015ELN ~ EZD100M3100ELN

4P Standard: EZD100M4015N ~ EZD100M4100N

4P Earth leakage: EZD100M4015ELN ~ EZD100M4100ELN

1.3 Type S (50el)

3P Standard: EZD100S3015N ~ EZD100S3100N

3P Earth leakage: EZD100S3015ELN ~ EZD100S3100ELN

4P Standard: EZD100S4015N ~ EZD100S4100N

4P Earth leakage: EZD100S4015ELN ~ EZD100S4100ELN

2 EZD160 Frame (160A)

Corriente nominal: 63, 80, 100, 125, 160A

2.1 Type E (25el)

3P Standard: EZD160E3063N, EZD160E3080N, EZD160E3100N, EZD160E3125N, EZD160E3160N

3P Earth leakage: EZD160E3063ELN, EZD160E3080ELN, EZD160E3100ELN, EZD160E3125ELN, EZD160E3160ELN

4P Standard: EZD160E4063N, EZD160E4080N, EZD160E4100N, EZD160E4125N, EZD160E4160N

4P Earth leakage: EZD160E4063ELN, EZD160E4080ELN, EZD160E4100ELN, EZD160E4125ELN, EZD160E4160ELN

2.2 Type M (36el)

3P Standard: EZD160M3063N ~ EZD160M3160N

3P Earth leakage: EZD160M3063ELN ~ EZD160M3160ELN

4P Standard: EZD160M4063N ~ EZD160M4160N

4P Earth leakage: EZD160M4063ELN ~ EZD160M4160ELN

2.3 Type S (50el)

3P Standard: EZD160S3063N ~ EZD160S3160N

3P Earth leakage: EZD160S3063ELN ~ EZD160S3160ELN

4P Standard: EZD160S4063N ~ EZD160S4160N

4P Earth leakage: EZD160S4063ELN ~ EZD160S4160ELN

3 EZD250 Frame (250A)

Corriente nominal: 100, 125, 160, 200, 225, 250A

3.1 Type E (25el)

3P Standard: EZD250E3100N, EZD250E3125N, EZD250E3160N, EZD250E3200N, EZD250E3225N, EZD250E3250N

3P Earth leakage: EZD250E3100ELN, EZD250E3125ELN, EZD250E3160ELN, EZD250E3200ELN, EZD250E3225ELN, EZD250E3250ELN

4P Standard: EZD250E4100N, EZD250E4125N, EZD250E4160N, EZD250E4200N, EZD250E4225N, EZD250E4250N

4P Earth leakage: EZD250E4100ELN, EZD250E4125ELN, EZD250E4160ELN, EZD250E4200ELN, EZD250E4225ELN, EZD250E4250ELN

3.2 Type M (36el)

3P Standard: EZD250M3100N ~ EZD250M3250N

3P Earth leakage: EZD250M3100ELN ~ EZD250M3250ELN

4P Standard: EZD250M4100N ~ EZD250M4250N

4P Earth leakage: EZD250M4100ELN ~ EZD250M4250ELN

3.3 Type S (50el)

3P Standard: EZD250S3100N ~ EZD250S3250N

3P Earth leakage: EZD250S3100ELN ~ EZD250S3250ELN

4P Standard: EZD250S4100N ~ EZD250S4250N

4P Earth leakage: EZD250S4100ELN ~ EZD250S4250ELN

4 EZD400 Frame (400A)

Corriente nominal: 200, 225, 250, 315, 400A

4.1 Type E (25el)

3P Standard: EZD400E3200N, EZD400E3225N, EZD400E3250N, EZD400E3315N, EZD400E3400N

3P Earth leakage: EZD400E3200ELN, EZD400E3225ELN, EZD400E3250ELN, EZD400E3315ELN, EZD400E3400ELN

4P Standard: EZD400E4200N, EZD400E4225N, EZD400E4250N, EZD400E4315N, EZD400E4400N

4P Earth leakage: EZD400E4200ELN, EZD400E4225ELN, EZD400E4250ELN, EZD400E4315ELN, EZD400E4400ELN

4.2 Type M (36el)

3P Standard: EZD400M3200N ~ EZD400M3400N

3P Earth leakage: EZD400M3200ELN ~ EZD400M3400ELN

4P Standard: EZD400M4200N ~ EZD400M4400N

4P Earth leakage: EZD400M4200ELN ~ EZD400M4400ELN

4.3 Type S (50el)

3P Standard: EZD400S3200N ~ EZD400S3400N

3P Earth leakage: EZD400S3200ELN ~ EZD400S3400ELN

4P Standard: EZD400S4200N ~ EZD400S4400N

4P Earth leakage: EZD400S4200ELN ~ EZD400S4400ELN

5 EZD630 Frame (630A)

Corriente nominal: 400, 500, 630A

5.1 Type E (25el)

3P Standard: EZD630E3400N, EZD630E3500N, EZD630E3630N

3P Earth leakage: EZD630E3400ELN, EZD630E3500ELN, EZD630E3630ELN

4P Standard: EZD630E4400N, EZD630E4500N, EZD630E4630N

4P Earth leakage: EZD630E4400ELN, EZD630E4500ELN, EZD630E4630ELN

5.2 Type M (36el)

3P Standard: EZD630M3400N, EZD630M3500N, EZD630M3630N

3P Earth leakage: EZD630M3400ELN, EZD630M3500ELN, EZD630M3630ELN

4P Standard: EZD630M4400N, EZD630M4500N, EZD630M4630N

4P Earth leakage: EZD630M4400ELN, EZD630M4500ELN, EZD630M4630ELN

5.3 Type S (50el)

3P Standard: EZD630S3400N, EZD630S3500N, EZD630S3630N

3P Earth leakage: EZD630S3400ELN, EZD630S3500ELN, EZD630S3630ELN

4P Standard: EZD630S4400N, EZD630S4500N, EZD630S4630N

4P Earth leakage: EZD630S4400ELN, EZD630S4500ELN, EZD630S4630ELN

General Notes

norte: Standard thermal-magnetic trip (LI for distribution protection)

ELN: With Vigi electronic earth leakage protection

Rotura: E=25kA, M=36kA, S=50kA

polacos: 3=3P, 4=4P

Anterior:

Próximo:

Deja una respuesta

Dejar un mensaje