Technical Specifications and Selection Guide for Schneider EZSS630F3630
EZSS630F3630 is a 3P 630A Moulded Case Circuit Breaker (MCCB) from Schneider Electric’s EasyPact EZS+ Series (Dunhuang Series). Its official order code is EZSS630F3630, with the full model description EZS-S630 36kA TM630D 3P3D, designed for power distribution protection.
- Model Code Explanation
| Segmento de modelo | Descripción |
| EZS | EasyPact EZS+ Series MCCB |
| S | Tipo estándar |
| 630 | Frame current 630A |
| F | Clase de capacidad de ruptura, 36el (415VACACIONES) |
| 3 | 3 polos |
| 630 | Rated current 630A |
| TM630D | Thermal‑magnetic trip unit, rated 630A, D‑curve |
- Parámetros técnicos básicos
| Artículo | Especificación |
| Tipo de producto | Moulded Case Circuit Breaker (MCCB) |
| Tensión nominal | 400/415VAC 50/60Hz |
| Corriente nominal (En) | 630A |
| Marco actual (Iu) | 630A |
| Número de polos | 3P3D (3‑pole, 3‑wire protection) |
| Máxima capacidad de rotura (uci) | 36el (415VACACIONES) |
| Capacidad de interrupción del servicio (ics) | 36el (100% uci) |
| Trip Unit | Thermal‑magnetic trip (TM‑D), with long‑time overload and instantaneous short‑circuit protection |
| Montaje | Fijado (estándar), plug‑in/withdrawable optional (with accessories) |
| Conexión | Conexión frontal (estándar), rear/plug‑in connection optional |
| Ingress Protection | IP30 (device body) |
| Ambient Conditions | Temperature ‑5℃~+40℃, altitud ≤2000m, grado de contaminación 2/3 |
| Standards | CEI 60947‑2, ES 14048.2 |
- Application Environment
- Aplicaciones principales
Main or branch switch in low-voltage distribution systems of industrial plants, commercial buildings and large public facilities
Secondary distribution, civil construction and electromechanical markets
Protect motors, transformadores, generators and other electrical equipment against overload and short-circuit damage
- Requisitos ambientales
Temperatura de funcionamiento: -5℃~+40℃ (derating required above 40℃)
Humedad relativa: ≤95%, non-condensing
Altitud: ≤2000m (derating required above 2000m)
Installation location: Indoor, vertical mounting (inclinación ≤5°)
Grado de contaminación: Grado 2 (estándar), applicable to degree 3 entornos (with special treatment)
- Cross-Brand Equivalent/Replacement Models
| Marca | Modelo de reemplazo | Observaciones |
| Schneider | CVS630F ETS2.3 630A 3P3D (LV563505) | Upgraded electronic trip unit with LSI protection |
| Schneider | NSX630F Micrologic 2.3 630A 3P3D (LV432876) | High‑performance flagship model, full electronic protection, communication optional |
| TEJIDO | Tmax T6N630 TMD 630/3P | Equivalent thermal‑magnetic MCCB |
| siemens | 3VA6300‑6EL32‑0AA0 | 630A 3P 36kA thermal‑magnetic MCCB |
| chint | NM1‑630S/3300 630A | Domestic alternative, 36kA capacidad de corte |
- Official Order Information
Official Order Code: EZSS630F3630
Common Accessories:
Auxiliary contact: LV429310 (1NO+1NC)
Shunt trip: LV429410 (220VACACIONES)
Undervoltage release: LV429510 (220VACACIONES)
Plug-in base: LV429100 (for 630A)
Motor mechanism: LV420089 (24VCC)
- Complete Model List of This Series (630A Frame)
| Modelo | Capacidad de ruptura | polacos | Corriente nominal | Trip Unit |
| EZSS630E3630 | 25el | 3PAG | 630A | TM‑D |
| EZSS630F3630 | 36el | 3PAG | 630A | TM‑D |
| EZSS630N3630 | 50el | 3PAG | 630A | TM‑D |
| EZSS630H3630 | 70el | 3PAG | 630A | TM‑D |
| EZSS630F4630 | 36el | 4PAG | 630A | TM‑D |
- Notas de instalación y mantenimiento
- Precauciones de instalación
For fixed mounting, reserve sufficient operating space (handle space ≥120mm)
Tighten terminals to specified torque (recommended for copper conductors: 40N·m for M10 bolts)
Maintain spacing ≥20mm between side-by-side units for proper heat dissipation
- Recomendaciones de mantenimiento
Inspección periódica (at least once per year): apariencia, fasteners, operating mechanism flexibility
After short-circuit tripping, inspect contact condition and replace if necessary
Thermal-magnetic trip units are non-adjustable; replace with electronic trip models if parameter adjustment is needed
- Selection and Replacement Recommendations
- Selection Factors
System short-circuit current level (ensure Icu ≥ calculated value)
Load type (D-curve for distribution protection, motor-specific type for motor protection)
Installation space and operation method
Future expansion (reserve 10%–20% margin)
- Soluciones alternativas
For more precise protection and adjustable parameters, upgrade to CVS630F ETS2.3 electronic trip model
For communication and remote monitoring, select NSX630F series with intelligent trip units such as Micrologic 5.3A
For budget-limited projects, consider domestic alternatives including Chint NM1 and Delixi CDM3 series
Detailed Connection Methods for Schneider EZSS630F3630
The standard connection method of Schneider EZSS630F3630 (EZS-S630 36kA TM630D 3P3D) is fixed front connection, with multiple optional connection configurations as follows:
- Basic Connection Methods and Configuration Options
| Mounting Type | Connection Direction | Supported | Observaciones |
| Fijado (Estándar) | Conexión frontal | ✓ Standard | Main circuit cables/busbars connected from front, easy operation, good heat dissipation |
| Fijado | Rear connection | ✓ Optional | Special configuration required, suitable for compact panel space |
| Plug‑in (Opcional) | Conexión frontal | ✓ Optional | Requires plug‑in base (p.ej. LV429100) for quick replacement and maintenance |
| Plug‑in | Rear connection | ✗ Not supported | Plug‑in rear connection not available for EZS+ 630A |
| Withdrawable | Any direction | ✗ Not supported | Withdrawable mounting not available for EZS+ series |
- Connection Technical Details
- Terminal Types
Circuito principal: Copper bolt terminals, suitable for cables or busbars
circuito de control (with auxiliary contacts, shunt/undervoltage releases): Plug-in terminals for easy secondary wiring
- Conductor Specifications
Suitable copper conductor cross-section: Up to 185mm² cable or equivalent busbar
Terminal tightening torque: 40N·m recommended for M10 bolts to ensure reliable connection
Supported connections: Direct cable connection, busbar connection (with dedicated clamps)
- Polarity and Phase Sequence
3P3D configuration: Connect L1, L2, L3 three-phase power; no neutral (norte) requerido
Markings: Clear phase sequence labels (1, 2, 3 correspond to L1, L2, L3) on the breaker body
- Connection Precautions and Specifications
- Preparación previa a la instalación
Ensure breaker is OFF, disconnect upstream power and verify voltage absence
Clean terminal surfaces and remove oxidation before connection
Select properly sized conductors to avoid overheating or improper fitting
- Estándares de cableado
Maintain equal length for each phase in main circuit to avoid unbalanced stress
Route control circuit separately from main circuit to reduce electromagnetic interference
Check terminal tightness after wiring to prevent loose connections
Ensure no tools or debris inside the breaker after wiring; reinstall protective covers
- Special Environment Requirements
Vertical mounting: Debe instalarse verticalmente (inclinación ≤5°) for proper arc extinction and mechanism operation
Derating: Derate accordingly when temperature >40℃ or altitude >2000metro, adjust conductor size accordingly
Grado de contaminación 3: Additional protection required to prevent dust and moisture from affecting insulation
- Recommended Connection Accessories
The following accessories are available for extended functions or special installations:
| Accesorio | Código de pedido | Función |
| Plug‑in base | LV429100 | For 630A, enables plug‑in mounting and front connection |
| Auxiliary contact | LV429310 | Provides 1NO+1NC signals for status indication or control |
| Shunt trip | LV429410 | Remote tripping at 220VAC, requires control power |
| Undervoltage release | LV429510 | Undervoltage protection at 220VAC, trips on power loss |
| Busbar clamps | Dedicated | Secure busbar fixation for reliable connection |
- Selection and Application Advice
- Configuración estándar: Fixed front connection preferred for general distribution, balancing cost and practicality
- Comodidad de mantenimiento: Plug-in front connection recommended for frequent maintenance, reduciendo el tiempo de inactividad
- Space Restrictions: Fixed rear connection can be used for limited cabinet depth, with sufficient operating space reserved
- Control Expansion: Reserve control wiring space and use suitable secondary accessories for remote control or monitoring
contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares