ParámetroValor
Serie de productosActi9 iCT
Corriente de funcionamiento nominal63A (AC-7a), 20A (AC-7b)
Tensión de funcionamiento nominal400V AC 50Hz
Control Voltage220~240V AC 50Hz
Tensión nominal de aislamiento500V y
Vida eléctrica100,000 operaciones (AC-7a), 30,000 operaciones (AC-7b)
Clase de protecciónIP20
Temperatura de funcionamiento-5℃~+60℃
Método de montaje35mm DIN Rail
Dimensiones (W×H×D)54mm×85mm×68mm (4P Type)

  • Detalles del producto

The Schneider ICT63A is a modular contactor de CA under Schneider Electric’s Acti9 series. It has a rated current of 63A and is specifically designed for residential and similar scenarios. It is suitable for remote control of motor control, iluminación, and heating equipment.

Parámetros principales

ParámetroValor
Serie de productosActi9 iCT
Corriente de funcionamiento nominal63A (AC-7a), 20A (AC-7b)
Tensión de funcionamiento nominal400V AC 50Hz
Control Voltage220~240V AC 50Hz
Tensión nominal de aislamiento500V y
Vida eléctrica100,000 operaciones (AC-7a), 30,000 operaciones (AC-7b)
Clase de protecciónIP20
Temperatura de funcionamiento-5℃~+60℃
Método de montaje35mm DIN Rail
Dimensiones (W×H×D)54mm×85mm×68mm (4P Type)

Nota: AC7a is suitable for slightly inductive loads (such as lighting), and AC7b is suitable for motor loads (como los fanáticos). The same contactor has different rated currents for different load types.

Main Models and Differences

ModeloNúmero de poloConfiguración de contactoSolicitud
A9C208633PAG3NO (Normalmente abierto)Three-phase motor control
A9C208644PAG4NO (Normalmente abierto)Three-phase + neutral line system, lighting control
A9C208684PAG2NO+2NC (Normalmente abierto + Normalmente cerrado)Control circuits requiring status feedback
A9C208674PAG4CAROLINA DEL NORTE (Normalmente cerrado)Special control requirements, such as safety circuits

Nota: Some models have manual operation versions (p.ej., A9C21864), which are suitable for commissioning and emergency situations.

Escenarios de aplicación

  1. Residential and Commercial Appliance Control:

Air conditioning compressor control

Heating equipment such as water heaters and electric stoves

Ventilation system and fan control

  1. Sistemas de iluminación:

Commercial lighting control

Timed/zoned control of lighting in public areas

  1. Control de motores pequeños:

Water pumps and compressors

Motors for rolling doors and garage doors

Small auxiliary motors in industrial equipment

Características técnicas

  1. Compact Design:

Modular structure with a width occupying only 6 modules of 9mm (54milímetros)

Saves space in distribution boxes and enables easy installation

  1. Low Power Consumption:

Pullin power consumption of 53VA and holding power consumption of only 6.5VA

Energyefficient and reduces heat generation

  1. Quiet Operation:

Optimized electromagnetic system design with noise below 30dB

Suitable for residences and places requiring a quiet environment

  1. Alta confiabilidad:

Cumple con IEC/EN 61095 estándares

Strong resistance to humidity and heat (works normally in an environment with 95% humidity and 55℃ temperature)

Electrical life of up to 100,000 operaciones (for AC7a loads)

  1. Safety Features:

Mechanical position indicator for easy status observation

IP20 protection to prevent accidental contact with live parts

Protective design for terminal blocks

Instalación y mantenimiento

Puntos clave de instalación

  1. Vertical Installation: The inclination angle should not exceed 5° to ensure good heat dissipation
  2. Conexión eléctrica:

Main circuit: 6~25mm² singlestrand hard wire or 6~16mm² flexible wire

circuito de control: 1.5~2.5mm² wires

Tightening torque: 3.5N·m for the main circuit and 0.8N·m for the control circuit

  1. Espacio de disipación de calor: Ensure sufficient ventilation space around the contactor

Recomendaciones de mantenimiento

Inspección periódica:

Check if contacts are ablated or deformed

Check if connections are loose

Remove dust and foreign objects

Maintenance Cycle:

Lowfrequency use (<15 operations/hour): Inspect once a year

Highfrequency use (>15 operations/hour): Inspect every 13 meses

Selection Considerations

  1. Selection Based on Load Type:

Slightly inductive loads such as lighting and heating: Select the rated current for AC7a (63A)

Motor loads: Select the rated current for AC7b (20A)

Cargas mixtas: Select according to the most severe conditions

  1. Selection Based on Voltage and Pole Number:

Singlephase loads: 2modelo P

Threephase loads: 3modelo P

Threephase + neutral line system: 4modelo P

The control voltage must be consistent with the system (usually 220~240V AC)

  1. Selection Based on Contact Configuration:

Only need to turn on/off: Select NO (Normalmente abierto) contacts

Need status feedback: Select NO+NC combination

Special safety control: Select NC (Normalmente cerrado) contacts

Resumen

The Schneider ICT63A Contactor is a highperformance, compact modular contactor. It is designed for residential and light commercial applications, with a rated current of 63A (AC7a) and multiple contact configuration options. It is suitable for motor control, iluminación, and heating equipment. Its features of low power consumption, quiet operation, and high reliability make it an ideal choice for residential, comercial, y aplicaciones industriales ligeras.