chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

TENSO DGK-04Relé de control - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

medidor de electricidad/eléctrico/

TENSO DGK-04Relé de control

TENSO DGK-04F Digital Adjustable 3-Phase Over&Under Voltage & Phase Sequence Control Relay Model Positioning & Core Functions TENSE DGK-04F is a digitally adjustable 3-phase over&under voltage+phase sequence control relay manufactured by TENSE Electronic (Pavo). It belongs to the DGK series protection and control products, designed specifically for industrial three-phase equipment. It monitors voltage anomalies (overvoltage/undervoltage) ...

  • Detalles del producto

TENSO DGK-04F Digital Adjustable 3-Phase Over&Under Voltage & Phase Sequence Control Relay

  1. Posicionamiento del modelo & Funciones principales

TENSO DGK-04F is a digitally adjustable 3-phase over&under voltage+phase sequence control relay manufactured by TENSE Electronic (Pavo). It belongs to the DGK series protection and control products, designed specifically for industrial three-phase equipment. It monitors voltage anomalies (overvoltage/undervoltage) and phase sequence errors simultaneously to prevent equipment damage caused by grid fluctuations or wiring mistakes.

Reglas de codificación de modelos (DGK-XXX)

SectionSignificadoEjemplo
DGKFixed prefix (digital adjustable 3-phase voltage control relay)DGK
4Function code (04=over&under voltage + phase sequence control, 03=over&under voltage control, 01=single-phase control)4
FVersion indicator (F=digital display/enhanced type, no suffix=basic type, PF=with phase failure protection)F
  1. Core Technical Specifications
Categoría de parámetroDetailed Specifications
Funciones de protección3-phase overvoltage protection, 3-phase undervoltage protection, phase sequence error protection, non-phase-sequence control (switchable)
Voltage Setting RangeSobretensión: 400V – 460V AC (ajustable); Subtensión: 230V – 360V AC (ajustable)
Tiempo de respuestaFault waiting time: 0.1s – 10s (ajustable), fast response to grid anomalies
Calificación de contacto5CA/250 VCA (carga resistiva), 1 NO + 1 NC contact configuration
Supply Voltage3-phase AC 380V (no neutral wire required), wide voltage design for global power grids
Frecuencia de funcionamiento50/60Hz (auto-adaptive)
Temperatura de funcionamiento-10°C to +55°C (industrial standard wide temperature range)
MontajeMontaje en carril DIN (standard 35mm) or front panel mounting, flexible for control cabinet layout
DimensionesDiseño compacto, ahorra espacio en el gabinete
CertificacionesCE, UL, CSA (compliant with international safety standards)
Grado de protecciónIP20 (debe instalarse en el gabinete de control)
Consumo de energíaLow power consumption, energy-saving and eco-friendly
  1. Características clave & Ventajas
  2. Three-in-one protection: Integrates overvoltage, subtensión, and phase sequence protection; one device solves multiple grid risks.
  3. Digital precise adjustment: Higher accuracy (±1V) than analog relays, with more intuitive settings.
  4. Non-phase-sequence control mode: Switchable via DIP switch, suitable for special applications without phase sequence protection.
  5. No neutral wire required: Direct 3-phase power supply, simplifies wiring and reduces installation cost.
  6. Stable wide-temperature operation: Adapts to harsh industrial environments and maintains reliable performance at high/low temperatures.
  7. Dual mounting methods: DIN rail or panel mounting to meet different cabinet design requirements.
  8. Clear fault indication: LED indicators intuitively show operating status and fault types for quick troubleshooting.
  9. DGK Series Full Model Comparison
ModeloFunciones de protecciónVoltage Setting RangeSpecial FeaturesSolicitud
DGK-01Single-phase over&under voltage protectionSobretensión: 230V–260V; Subtensión:170V–220VSingle-phase dedicated, tamaño más pequeñoLighting systems, small single-phase equipment
DGK-033-phase over&under voltage protectionSobretensión:400V–460V; Subtensión:230V–360Vtipo básico, cost-optimizedGeneral 3-phase motors, zapatillas
DGK-043-phase over&under voltage + protección de secuencia de fasesSobretensión:400V–460V; Subtensión:230V–360VNo digital display, basic functionsGeneral industrial equipment, budget-limited projects
DGK-04F3-phase over&under voltage + protección de secuencia de fasesSobretensión:400V–460V; Subtensión:230V–360VDigital display, adjustable parametersPrecision equipment, key production lines, automation systems
DGK-04PF3-phase over&under voltage + phase sequence + phase failure protectionSobretensión:400V–460V; Subtensión:230V–360VFull-function protection, including phase loss detectionCritical equipment, continuous production systems
  1. Escenarios de aplicación típicos
  2. Industrial motor protection: 3-phase asynchronous motors, compresores, zapatillas; prevents winding burnout from abnormal voltage or mechanical damage from reverse rotation due to phase sequence error.
  3. Líneas de producción automatizadas: PLC control systems, robot workstations, CNC machines; ensures stable operation of precision equipment and avoids production interruptions caused by grid fluctuations.
  4. Building electrical systems: Central air conditioning, ascensores, pump rooms; protects key building equipment and improves power supply reliability.
  5. Renewable energy: PV inverters, wind power equipment; adapts to unstable new energy output and protects grid-connected devices.
  6. Petrochemical industry: Auxiliary equipment outside hazardous areas; wide-temperature design adapts to high-temperature refinery environments.
  7. Maquinaria minera: Crushers, transportadores; withstands harsh grid conditions and prevents frequent equipment failures.
  8. Alternative Products & Order Codes from Other Brands

6.1 Alternativas de marcas internacionales (Equivalent Function)

TENSE ModelMarcaAlternative ModelCódigo de pedidoKey Matching Points
DGK-04Fsiemens3UG4632-1AW303UG4632-1AW303-phase over&under voltage + protección de secuencia de fases, pantalla digital, adjustable parameters
DGK-04FSchneiderRM22TG20RM22TG203-phase voltage monitoring, over&under voltage + protección de secuencia de fases, 5A contacts
DGK-04FTEJIDOCM-PVS.41S1SVR730820R12003-phase over&under voltage + phase sequence + phase loss protection, full grid monitoring
DGK-04FOmronK8DS-PH3K8DS-PH3Digital 3-phase voltage & phase sequence relay, adjustable response time

6.2 Chinese Brand Alternatives (Cost-Effective)

TENSE ModelMarcaAlternative ModelCódigo de pedidoKey Matching Points
DGK-04FCHINTNJD-8NJD-83-phase over&under voltage + protección de secuencia de fases, affordable, suitable for domestic grids
DGK-04FDeliciosoCDJS1CDJS1Digital display, comprehensive 3-phase voltage & protección de secuencia de fases, 5A contact rating
DGK-04FChangshu SwitchCK3-32CK3-32Triple protection: over&under voltage + phase sequence + pérdida de fase, industrial-grade reliability
  1. Key Points for Selection & Reemplazo

7.1 Core Matching Dimensions (Must Check for Replacement)

DimensionEstándar coincidenteNotas
Funciones de protecciónFully consistent (sobretensión + subtensión + phase sequence)Avoid insufficient protection due to missing functions
Calificación de contacto≥5A/250V ACEnsure it can drive control circuit loads
Supply Voltage3-phase 380V (no neutral wire)Match original system power to avoid complex wiring
Tiempo de respuesta0.1–10s adjustableShort-delay models required for fast-response equipment
MontajeMontaje en carril DINMaintain consistent control cabinet layout

7.2 Replacement Implementation Recommendations

  1. Parameter migration: Record overvoltage/undervoltage thresholds, response time and other parameters of the original DGK-04F, and set identical parameters on the new device after replacement.
  2. Wiring verification: 3-phase power wiring must be consistent with the original system; phase sequence errors cause false protection.
  3. Function test: After replacement, perform simulated overvoltage, undervoltage and phase sequence error tests to verify normal protection functions.
  4. Redundant configuration: Paired configuration is recommended for critical equipment to improve system reliability.
  5. Guía de selección rápida
SolicitudPreferred ModelAlternative SuggestionBudget Reference
Key production lines / equipo de precisiónDGK-04PF (protección de función completa)Siemens 3UG4632-1AW30Medium–high budget
General industrial motors / zapatillasDGK-04FSchneider RM22TG20Medium budget
Proyectos sensibles a los costos / civil buildingsDGK-04CHINT NJD-8 / Delixi CDJS1Low budget

Complete Manual of TENSE Relay Product Series Codes

  1. Voltage Control Relays (Core Protection Series)

1.1 Classic Analog Type (GK Series)

ModeloDescripción de la funciónSolicitud
GKE-40Single-phase over&under voltage control relayResidential/commercial single-phase equipment protection
GKV-12Single-phase over&under voltage control relaySmall single-phase motors, pump control
GKV-12FSingle-phase over&under voltage control relay (enhanced)Precision single-phase equipment requiring digital display
GK-033-phase over&under voltage control relayBasic voltage protection for 3-phase motors
GK-043-phase over&under voltage + relé de control de secuencia de fases3-phase equipment protection against wiring errors + voltage anomalies
GK-04F3-phase over&under voltage + relé de control de secuencia de fases (pantalla digital)3-phase equipment requiring status indication
GK-04S3-phase over&under voltage + relé de control de secuencia de fases (special version)Custom for specific industrial scenarios
GKM-11Single-phase over&under voltage control relay (high sensitivity)Voltage fluctuation-sensitive equipment
GKM-02Single-phase over&under voltage control relay (compact)Installation in narrow control cabinets
GKM-02FSingle-phase over&under voltage control relay (compact + display)Small equipment + monitoreo de estado
GKT-033-phase over&under voltage control relay (wide range)Special voltage-class 3-phase systems
GKT-03F3-phase over&under voltage control relay (wide range + display)Wide voltage range + status display

1.2 Digital Adjustable Type (DGK Series)

ModeloDescripción de la funciónSolicitud
DGK-01Digital adjustable single-phase over&under voltage control relayPrecision single-phase equipment with precise parameter adjustment
DGK-03Digital adjustable 3-phase over&under voltage control relay3-phase motors requiring accurate voltage protection
DGK-04Digital adjustable 3-phase over&under voltage + relé de control de secuencia de fasesComprehensive protection for standard 3-phase equipment
DGK-04FDigital adjustable 3-phase over&under voltage + relé de control de secuencia de fases (pantalla digital)Industrial automation production lines requiring status monitoring
DGK-04PFDigital adjustable 3-phase over&under voltage + phase sequence + phase failure protection relay (full-function)Critical equipment requiring complete grid monitoring
  1. Current Protection Relays (Sobrecarga / Protección de pérdida de fase)
ModeloDescripción de la funciónSolicitud
TRM-100Digital 3-phase overload protection relaySobrecarga, rotor bloqueado, phase loss protection for 3-phase motors
TRM-200Digital 3-phase overload protection relay (extended)Large 3-phase motors with multi-parameter adjustment
DR-01Single-phase current protection relayOverload protection for single-phase motors
DR-023-phase current protection relayBasic current protection for small 3-phase motors
  1. Time Relays (Delay Control Series)

3.1 Digital Programmable Type

ModeloDescripción de la funciónRango de tiempo
TTR-10Digital programmable multi-function time relay0.01s – 9999h, multiple modes
TTR-20Digital programmable time relay (salida dual)Complex control logic requiring two delay groups

3.2 Analog Timing Type

ModeloDescripción de la funciónRango de retardo
TT-01Single delay time relay0.1s – 10s
TT-02Dual delay time relay0.1s – 60s
TT-03Long delay time relay1s – 10min
  1. Temperature Control Relays (Temperature Monitoring & Protección)
ModeloDescripción de la funciónRango de temperatura
DT-96YDigital temperature control relay (96mm panel)-50°C ~ +150°C
DT-72YDigital temperature control relay (72mm panel)-50°C ~ +150°C
DT-48YDigital temperature control relay (48mm panel)-50°C ~ +150°C
DT-36YDigital temperature control relay (36mm panel)-50°C ~ +150°C
DT-72EMDigital temperature control relay (enhanced, with communication)-50°C ~ +200°C, for remote monitoring
DT-YUniversal digital temperature control relay-50°C ~ +150°C, compact
DT-96E/DT-72E/DT-48E/DT-36EDigital temperature control relay (extended functions)-50°C ~ +200°C, multiple output modes
DT-322Dual-channel temperature control relaySimultaneous monitoring of two temperature points
DTZ-96/DTZ-72/DTZ-48Intelligent temperature control relay (with PID regulation)Precision temperature control systems (hornos, furnaces)
TK-1/TK-1.5/TK-2/TK-2.5/TK-3/TK-4/TK-5Relé de sobrecarga térmicaMotor winding temperature protection, used with contactors
PT-1/PT-3Temperature probe dedicated relayTemperature sensor signal conversion & control
  1. Submersible Pump Control Relays (Special Control Series)
ModeloDescripción de la funciónMétodo de control
TDK-96Intelligent 3-phase submersible pump control relay (2.9″ graphic LCD)Electrode-less well control, 1A–250A current range
TDK-023-phase submersible pump control relay (basic)Ordinary well submersible pumps, basic protection
MDK-02Single-phase submersible pump control relaySmall single-phase submersible pumps, household/farm use
TDK-973-phase submersible pump control relay (enhanced)Large submersible pumps with fault recording
  1. Power Factor Controllers (Reactive Power Compensation Series)

6.1 Three-Phase Series (RGT Series)

ModeloDescripción de la funciónCompensation Stages
RGT-083-phase power factor controller8-stage compensation
RGT-123-phase power factor controller12-stage compensation, graphic LCD
RGT-12M3-phase power factor controller (memory)12-stage, power-off memory
RGT-12H3-phase power factor controller (with communication)12-stage, Modbus communication
RGT-12TH3-phase power factor controller (thyristor trigger)12-stage, contactless switching
RGT-183-phase power factor controller18-stage compensation
RGT-18H3-phase power factor controller (with communication)18-stage, Modbus communication
RGT-18TH3-phase power factor controller (thyristor trigger + comunicación)18-stage, contactless + comunicación
RGT-24H3-phase power factor controller (with communication)24-stage compensation, Modbus communication
RGT-MT183-phase digital power factor controller (advanced)18-stage, multi-parameter adjustable
RGT-12SVC/RGT-18SVC/RGT-MT18 SVC3-phase static var compensator controllerDynamic reactive power compensation, fast response

6.2 Single-Phase Series (RGM Series)

ModeloDescripción de la funciónCompensation Stages
RGM-07ESingle-phase power factor controller7-stage compensation
RGM-12ESingle-phase power factor controller12-stage compensation
RGM-12ERSingle-phase power factor controller (with communication)12-stage, Modbus communication
RGM-12SSingle-phase power factor controller (simple)12-stage, basic functions
  1. Special Function Relays (Customized Applications)
ModeloDescripción de la funciónSolicitud
DGR-01Earth fault protection relayEquipment earth fault detection, electric shock prevention
DGT-02Digital earth fault protection relayPrecision equipment requiring earth current digital display
TKR-01Star-delta starting relayStar-delta reduced-voltage starting control for 3-phase motors
TSR-02Auto-transformer starting relayAuto reduced-voltage starting control for large motors
PSR-03Phase sequence protection relay (independent)3-phase equipment requiring only phase sequence protection
  1. Model Coding Rule Analysis

8.1 Voltage Control Relays (GK/DGK Series)

Code SegmentSignificadoEjemplo
GRAMOFixed prefix (voltage control)GK-04F
KFunction type (K=control)DGK-04PF
incógnitaPhase / characteristics (E=single-phase, 03=3-phase over&under voltage, 04=3-phase over&under voltage + phase sequence)GKE-40
Suffix FEnhanced type (pantalla digital / extended functions)GK-04F
Prefix DDigital adjustable typeDGK-01
Suffix PFCon protección contra fallo de faseDGK-04PF

8.2 Power Factor Controllers (RGT/RGM Series)

Code SegmentSignificadoEjemplo
RGFixed prefix (reactive power control)RGT-12
T/MPhase (T=3-phase, M=single-phase)RGM-12E
NumberCompensation stages (08=8, 12=12, 18=18)RGT-18
Suffix HWith communication functionRGT-12H
Suffix THThyristor trigger outputRGT-12TH
Suffix SVCStatic var compensationRGT-12SVC
  1. Series Quick Reference Guide
Product CategoryCore SeriesRepresentative ModelFunciones principales
Voltage ProtectionGK/DGKDGK-04FOver&under voltage + protección de secuencia de fases, digital adjustable
Current ProtectionTRM/DRTRM-100Sobrecarga + pérdida de fase + locked rotor protection
Time ControlTTR/TTTTR-10Multi-function programmable delay
Control de temperaturaDT/DTZDT-96YDigital temperature monitoring & control
Pump ControlTDK/MDKTDK-96Comprehensive submersible pump protection & control
Reactive Power CompensationRGT/RGMRGT-12HPower factor optimization, energy saving

Complete Analysis of TENSE ERV Series Time Relays (Including Models, Presupuesto, Applications & Alternativas)

  1. Series Positioning & Funciones principales

TENSE ERV series is the economy time relay product line of TENSE Electronic (Pavo), focusing on delay control and sequential logic in industrial automation. It covers basic on-delay, multi-function cycle, star-delta starting and other special applications. With compact design, wide voltage adaptability and high cost performance as core advantages, it is widely used in motor control, production line automation, building electrical and other fields.

Core Features of the Series

  1. Diseño modular: Standard 22.5mm DIN rail mounting, ahorra espacio en el gabinete.
  2. Wide voltage supply: 150–260V AC / 24V AC/DC auto-adaptive, suitable for global power grids.
  3. Alta confiabilidad: IP40 protective shell, V-0 flame retardant material, adapts to harsh industrial environments.
  4. Configuración flexible: Knob / DIP / button adjustment methods to meet different accuracy requirements.
  5. Protección integral: Sobrecarga, cortocircuito, overvoltage protection to extend service life.
  6. Reglas de codificación de modelos (ERV-XX[D/F/M/YU/STER])
Code SegmentSignificadoEjemplo
ERVFixed prefix (economy time relay)ERV-12, ERV-09D
XXBasic time range (03=0.1–3min, 09=0.1–9min, 12=0.1–12sec, 30=0.1–30min, 60=0.1–60min, 08=0.1sec–100h)ERV-30, ERV-08
DMulti-function type (includes on-delay, off-delay, cycle, etc.)ERV-03D, ERV-60D
FFlashing type (dual time setting: run time + stop time)ERV-09F
METROMemory type (retains settings after power failure)ERV-08METRO
YU/STERStar-delta dedicated (built-in Y-Δ conversion logic, fixed short delay)ERV-YU, ERV-STER
  1. ERV Series Complete Model List (By Function)

3.1 Basic On-Delay Type (No Suffix D)

ModeloRango de retardoConfiguración de contactoSolicitud
ERV-120.1s – 12s (ajustable)1 NO + 1 CAROLINA DEL NORTEShort delay control (válvulas solenoides, cylinder fast action)
ERV-030.1s – 3min (ajustable)1 NO + 1 CAROLINA DEL NORTEMedium delay (fans, pump start delay)
ERV-090.1s – 9min (ajustable)1 NO + 1 CAROLINA DEL NORTELong delay (calentadores, lighting system delay)
ERV-300.1s – 30min (ajustable)1 NO + 1 CAROLINA DEL NORTEExtra-long delay (equipment preheating, cooling delay)
ERV-600.1s – 60min (ajustable)1 NO + 1 CAROLINA DEL NORTEUltra-long delay (intermittent production, timed shutdown)
ERV-080.1s – 100h (ajustable)1 NO + 1 CAROLINA DEL NORTEVery long delay (periodic maintenance reminder, backup equipment switching)

3.2 Multi-Function Delay Type (Suffix D)

ModeloRango de retardoModesFunciones especialesSolicitud
ERV-03D0.1s – 3min (ajustable)5+On-delay, off-delay, single pulse, interval pulsePequeños equipos de automatización., multi-logic control
ERV-09D0.1s – 9min (ajustable)5+Cycle control (run-stop alternating), flashing modeWarning lights, intermittent pumps, advertising light boxes
ERV-30D0.1s – 30min (ajustable)5+Extended delay range for medium-long cycle controlProduction line segment control, material conveying delay
ERV-60D0.1s – 60min (ajustable)5+Dual delay setting for complex sequential logicLarge equipment startup process, multi-level safety interlock

3.3 Special Function Type (Special Suffix)

ModeloFunction TypeParámetros principalesSolicitud
ERV-09FFlashing relayRun:0.1sec–99min, Detener:0.1sec–99minWarning lights, alarms, signal indication
ERV-08METROMemory delay relay0.1sec–100h, power-off parameter retentionUnattended equipment, emergency systems
ERV-YUStar-delta starting relayY delay:0.1–30sec, Y-Δ switch:10–500msec (ajustable)Star-delta reduced-voltage starting for 3-phase asynchronous motors
ERV-STERStar-delta starting relay (enhanced)Y delay:0.1–30sec, Y-Δ switch:15msec (fixed), LED statusPrecision motor control (compresores, zapatillas)
ERV-09DDDual-output delay relayTwo independent delay controls, 0.1–9minSequential control of two independent devices
  1. Core Technical Specifications Comparison (Full Series)
Categoría de parámetroBasic Type (ERV-XX)Multi-Function Type (ERV-XXD)Star-Delta Dedicated (ERV-YU/STER)Flashing Type (ERV-09F)
Calificación de contacto5CA/250 VCA (resistador)5CA/250 VCA (resistador)5CA/250 VCA (resistador)5CA/250 VCA (resistador)
Configuración de contacto1 NO + 1 CAROLINA DEL NORTE1 NO + 1 CAROLINA DEL NORTE2 NO + 1 CAROLINA DEL NORTE (star-delta dedicated)1 NO + 1 CAROLINA DEL NORTE
Supply Voltage150–260V AC/24V AC/DC150–260V AC/24V AC/DC150–260V AC/24V AC/DC150–260V AC/24V AC/DC
Frecuencia de funcionamiento50/60Hz (auto-adaptive)50/60Hz (auto-adaptive)50/60Hz (auto-adaptive)50/60Hz (auto-adaptive)
Temperatura de funcionamiento-10°C to +55°C-10°C to +55°C-10°C to +55°C-10°C to +55°C
Consumo de energía<4Virginia<4Virginia<4Virginia<4Virginia
MontajeCarril DIN (35milímetros)Carril DIN (35milímetros)Carril DIN (35milímetros)Carril DIN (35milímetros)
Dimensiones22.5×67×76mm22.5×67×76mm22.5×67×76mm22.5×67×76mm
CertificacionesCE, UL, CSACE, UL, CSACE, UL, CSACE, UL, CSA
  1. Escenarios de aplicación típicos
  2. Control de motores

ERV-YU/STER: Star-delta starting for 3-phase motors (7.5kW–90kW)

ERV-30D: Motor overload protection delay to prevent frequent starting

ERV-03: Delayed start of motor auxiliary equipment (fans, oil pumps)

  1. Líneas de producción automatizadas

ERV-12: Short-cycle action control (cylinder extension, material pushing)

ERV-60D: Inter-process delay to ensure material in place and temperature compliance

ERV-08: Long-cycle equipment maintenance reminders (filter replacement, lubrication)

  1. Building Electrical Systems

ERV-09F: Emergency lighting flashing control, exit indication

ERV-30: Delayed start of air conditioning and ventilation to balance grid load

ERV-60: Timed control of public area lighting for energy saving

  1. Special Industrial Applications

ERV-09DD: Dual-station switching control for welding equipment

ERV-08METRO: Delayed closing of cold storage doors to prevent cold air loss

ERV-60D: Chemical dosing and backwash sequence control in water treatment systems

  1. Alternative Products & Order Codes from Other Brands

6.1 Alternativas de marcas internacionales (Equivalent Function)

TENSE ModelMarcaAlternative ModelCódigo de pedidoKey Matching Points
ERV-03Dsiemens3RP1505-1BQ303RP1505-1BQ300.1–3min delay, multi-function, Carril DIN
ERV-60DSchneiderRE17R12MWRE17R12MW0.1–60min delay, multiple modes, wide voltage
ERV-YUTEJIDOCT-MPS.211SVR730820R1200Star-delta starting, 0.1–30sec delay, salida dual
ERV-09FOmronH3CR-F8H3CR-F8Flashing control, dual time setting, 5A contacts

6.2 Chinese Brand Alternatives (Cost-Effective)

TENSE ModelMarcaAlternative ModelCódigo de pedidoKey Matching Points
ERV-03DCHINTJSZ3A-AJSZ3A-AOn-delay, 0.1–3min, 1 NO + 1 CAROLINA DEL NORTE
ERV-60DDeliciosoCDJS1-60CDJS1-60Multi-function delay, 0.1–60min, wide voltage
ERV-YUChangshu SwitchCK3-YDCK3-YDStar-delta starting, 0.1–30sec, LED indication
ERV-08METROTianshui 213JSZ8-08MJSZ8-08MMemory delay, 0.1sec–100h, power-off retention
  1. Key Points for Selection & Reemplazo

7.1 Core Matching Dimensions (Must Check for Replacement)

DimensionEstándar coincidenteNotas
Rango de retardoCovers original equipment requirements (p.ej., 0.1–30sec → ERV-YU)Avoid insufficient or redundant time range
Configuración de contactoSame quantity & tipo (e.g.,1 NO+1 NC →1 NO+1 NC)Star-delta applications require 2 NO+1 NC
Supply VoltageAdapt to original system (150–260V AC/24V DC)Avoid damage due to voltage mismatch
MontajeMontaje en carril DIN (22.5mm standard size)Maintain consistent cabinet layout
Function ModeSame core function (flashing→flashing, star-delta→star-delta)Multi-function type can replace basic type

7.2 Recomendaciones de selección

  1. Basic delay control: Prioritize ERV-XX series (ERV-12 for 0.1–12sec, ERV-03 for 0.1–3min)
  2. Complex sequential control: Choose ERV-XXD multi-function type (supports multiple delay modes)
  3. Motor starting applications: Star-delta starting must use ERV-YU/STER dedicated models for accurate switching timing
  4. Long-cycle control: Choose ERV-08/08METRO (0.1sec–100h) for unattended scenarios
  5. Budget-sensitive projects: Chinese brand alternatives (CHINT, Delicioso) reduce cost by 30%–50%
  6. Guía de selección rápida
SolicitudPreferred TENSE ModelAlternative SuggestionBudget Reference
3-phase motor star-delta startingERV-YU/STERABB CT-MPS.21 / CHINT CK3-YDMedium–low budget
Short-cycle control (<1min)ERV-03/ERV-03DSiemens 3RP1505 / Delixi CDJS1-03Low budget
Long-cycle control (>1min)ERV-30/ERV-60DSchneider RE17R12MW / CHINT JSZ3CMedium budget
Flashing / alarm controlERV-09FOmron H3CR-F8 / CHINT JSZ3FLow budget
Memory controlERV-08METROTianshui 213 JSZ8-08MMedium budget

Anterior:

Deja una respuesta

Dejar un mensaje