Schneider ElectricGV2-ME21C is a 3-pole thermal-magnetic motor protection circuit breaker belonging to the TeSys GV2M series. Its core parameters cover electrical, protección, mechanical and environmental dimensions. Below is the structured and complete technical parameter sheet:

  1. Parámetros eléctricos básicos
Elemento de parámetroValorStandard/Remarks
Tensión de funcionamiento nominal (Ue)690V y (CEI 60947-2); 600V y (UL 508)Suitable for three-phase industrial circuits
Tensión nominal de aislamiento (interfaz de usuario)690V yBenchmark for insulation safety
Rated Impulse Withstand Voltage (Uimp)6kVSurge resistance capability
Thermal Overload Setting Current (Y)17-23A10-level adjustable, suitable for motors of corresponding power
Corriente de funcionamiento nominal (Ith)23AUpper limit of long-term current carrying capacity
Número de polo3-poloProtection for the main circuit of three-phase motors
Utilization CategoryAC-3 (CEI 60947-4-1); Category A (CEI 60947-2)Suitable for motor starting, stopping and operation
Método de controlPush-button type (handle operation)Convenient for closing, opening and trip testing
  1. Protection and Breaking Capacity
Elemento de parámetroValorApplicable Conditions
Ultimate Short-Circuit Breaking Capacity (uci)3kA@690V AC; 15kA@400/415V AC; 50kA@230/240V AC; 6kA@440V AC; 4kA@500V AC50/60Hz, Cumple con IEC 60947-2
Service Short-Circuit Breaking Capacity (ics)75% Icu@690V AC; 50% Icu@440V ACCan continue to be used after breaking
Corriente de disparo magnético327-390A (aprox. 15-17 times of Ir)Threshold for instantaneous short-circuit protection
Protección de pérdida de faseAvailableReliable tripping in case of three-phase unbalance
Protección contra sobrecarga térmica10-level ambient compensationSuitable for working conditions from -20℃ to +60℃
  1. Mechanical and Installation Parameters
Elemento de parámetroValorStandard/Remarks
Método de montaje35mm standard DIN rail (EN 60715) / screw mountingDIN rail mounting is preferred; screw hole spacing is approx. 45milímetros
Mounting PositionHorizontal/VerticalFlatness error ≤ 0.5mm/m
Tipo de terminalScrew-clamp typeSuitable for 2.5-4mm² copper core wires, torque 1.5-2.5N·m
Dimensiones generales (Alto×Ancho×Profundidad)89mm×44.5mm×78.2mmCompact design, ahorrando espacio en el gabinete
PesoAprox.. 0.26kilosLightweight, easy to install
Electrical Service Life100,000 operacionesDurability of closing and opening cycles
Vida útil mecánica200,000 operacionesReliability of the operating mechanism
  1. Environmental and Protection Parameters
Elemento de parámetroValorStandard/Remarks
Ingress Protection Rating (IP)IP20 (main unit)CEI 60529, protection against finger touch
Mechanical Impact Resistance Rating (IK)IK04Resistance to mechanical impact
Temperatura de funcionamiento-20℃~+60℃Wide temperature range for industrial applications
Storage Temperature-40℃~+85℃No condensation or corrosive gas
CertificacionesCEI, UL, CSA, CCC, CAO, Green Premium (RoHS/REACH)Compliant with multiple global regional standards
  1. Applicable Motor Power (Reference)
Voltage LevelApplicable Motor Power
400/415V y9KW
500V y11KW
690V y18.5KW
  1. Supplementary Core Features
  2. The handle can be locked in the OFF position to prevent accidental closing and improve maintenance safety.
  3. Auxiliary contact modules such as GV2-AE11 (1NO+1NC) can be added for signal feedback or control circuit expansion.
  4. The terminals are suitable for multi-strand flexible wires (cold-pressed terminals are required) to avoid heating caused by loose wiring.