T6V 800 PR221DS|ABB Tmax T6 Series High Performance Moulded Case Circuit Breaker (MCCB)
Modèle complet: T6V 800 PR221DS-LS/I In=800 (Common Order Codes: 1SDA069432R1, 1SDA069429R1, 3P/4P selectable)
Marque: ABB (SACE Tmax Series)
- Detailed Model Interpretation
| Segment de modèle | Signification | Key Description |
| T6 | Series Designation | Tmax T6 series, frame current 800A, suitable for medium and high voltage power distribution systems |
| V | Breaking Capacity Class | Class V, ultra-high breaking capacity: 120kA at 400V, 200kA at 220V |
| 800 | Courant nominal | 800UN (same as frame current) |
| PR221DS | Trip Unit Type | Electronic intelligent trip unit with LS/I protection (Long-time delay L, Short-time delay S, Instantaneous I) |
| LS/I | Protection Configuration | Standard three-stage protection; earth fault protection optional (extra configuration required) |
| F F | Montage / Connexion | First F: Fixed mounting; Second F: Connexion frontale |
- Paramètres techniques de base
| Article | Spécification | Remarques |
| Tension nominale (Ue) | 690V et | Suitable for industrial high-voltage power distribution systems |
| Tension d'isolation nominale (Interface utilisateur) | 1000V et | Higher than rated operating voltage, large safety margin |
| Ultimate Breaking Capacity (ICU) | 120kA@400V, 200kA@220V | Highest Class V, adapté aux environnements industriels difficiles |
| Rated Operational Current (Dans) | 800UN | Maximum continuous operating current |
| Poteaux | 3P/4P selectable | 3P for three-phase circuits, 4P includes neutral protection |
| Caractéristique du voyage | LS/I three-stage protection | Long-time delay inverse time, short-time / instantaneous definite time |
| Mounting Type | Fixé | Draw-out type also available (special model required) |
| Connection Type | Connexion frontale | Compatible with cables or busbars |
| Degree of Protection | IP30 | Standard switchgear installation protection |
| Applicable Standard | CEI 60947-2 | International standard for low-voltage switchgear |
- Principales fonctionnalités & Applications
Avantages principaux
- Ultra-high breaking capacity: Class V can withstand severe short-circuit faults and ensure system safety
- Intelligent protection: PR221DS trip unit provides accurate overload and short-circuit protection with adjustable parameters
- Reliable and durable: ABB Tmax series design, suitable for frequent operation and harsh industrial environments
- Flexible extension: Supports various accessories (contacts auxiliaires, alarm contacts, déclencheur à minimum de tension, etc.)
Applications typiques
Main power distribution systems in large industrial plants
690V high-voltage Motor Control Centers (MCC)
Power supply for data centers and critical infrastructure
Combiner box protection for new energy power systems (PV, wind power)
Marine and offshore platform power distribution systems
- Reference Replacement Models
Same-brand Upgrades / Replacements
| Modèle | Capacité de coupure | Type de voyage | Application |
| T6V 800 PR222DS-LSIG | 120kA@400V | With earth fault protection (G) | Systems requiring earth fault detection |
| T6V 800 PR223DS | 120kA@400V | Advanced intelligent trip unit | Applications requiring remote monitoring and communication |
| T6S 800 PR221DS | 70kA@400V | Standard breaking capacity | General industrial power distribution, lower cost |
Alternatives multimarques
| Marque | Modèle | Paramètres de correspondance clés |
| Schneider | Masterpact MT25H1 800A | 800UN, 120kA breaking, three-stage protection |
| Siemens | 3WL1210-3BB36-4GA4 | 800UN, 100kA breaking, intelligent trip unit |
| Mitsubishi | NF800-SEW | 800UN, 100kA breaking, electronic trip unit |
- Notes de sélection
- Breaking capacity matching: Select V/S/H/N/L classes based on system short-circuit current calculation
- Protection function selection: Basic LS/I meets most needs; choose LSIG for earth fault protection
- Mounting type: Fixed for standard switchgear, draw-out for easy maintenance and replacement
- Accessory configuration: Select auxiliary contacts, alarm contacts, motor operators, etc., according to control requirements
- Voltage compatibility: T6V suitable for systems up to 690V; use dedicated 1000V series (par ex., T6L) for higher voltages
Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires