ABB MCCB T6V 800 PR221DS

T6V 800 PR221DS|ABB Tmax T6 Series High Performance Moulded Case Circuit Breaker (MCCB)

Modèle complet: T6V 800 PR221DS-LS/I In=800 (Common Order Codes: 1SDA069432R1, 1SDA069429R1, 3P/4P selectable)

Marque: ABB (SACE Tmax Series)

  1. Detailed Model Interpretation
Segment de modèleSignificationKey Description
T6Series DesignationTmax T6 series, frame current 800A, suitable for medium and high voltage power distribution systems
VBreaking Capacity ClassClass V, ultra-high breaking capacity: 120kA at 400V, 200kA at 220V
800Courant nominal800UN (same as frame current)
PR221DSTrip Unit TypeElectronic intelligent trip unit with LS/I protection (Long-time delay L, Short-time delay S, Instantaneous I)
LS/IProtection ConfigurationStandard three-stage protection; earth fault protection optional (extra configuration required)
F FMontage / ConnexionFirst F: Fixed mounting; Second F: Connexion frontale
  1. Paramètres techniques de base
ArticleSpécificationRemarques
Tension nominale (Ue)690V etSuitable for industrial high-voltage power distribution systems
Tension d'isolation nominale (Interface utilisateur)1000V etHigher than rated operating voltage, large safety margin
Ultimate Breaking Capacity (ICU)120kA@400V, 200kA@220VHighest Class V, adapté aux environnements industriels difficiles
Rated Operational Current (Dans)800UNMaximum continuous operating current
Poteaux3P/4P selectable3P for three-phase circuits, 4P includes neutral protection
Caractéristique du voyageLS/I three-stage protectionLong-time delay inverse time, short-time / instantaneous definite time
Mounting TypeFixéDraw-out type also available (special model required)
Connection TypeConnexion frontaleCompatible with cables or busbars
Degree of ProtectionIP30Standard switchgear installation protection
Applicable StandardCEI 60947-2International standard for low-voltage switchgear
  1. Principales fonctionnalités & Applications

Avantages principaux

  1. Ultra-high breaking capacity: Class V can withstand severe short-circuit faults and ensure system safety
  2. Intelligent protection: PR221DS trip unit provides accurate overload and short-circuit protection with adjustable parameters
  3. Reliable and durable: ABB Tmax series design, suitable for frequent operation and harsh industrial environments
  4. Flexible extension: Supports various accessories (contacts auxiliaires, alarm contacts, déclencheur à minimum de tension, etc.)

Applications typiques

Main power distribution systems in large industrial plants

690V high-voltage Motor Control Centers (MCC)

Power supply for data centers and critical infrastructure

Combiner box protection for new energy power systems (PV, wind power)

Marine and offshore platform power distribution systems

  1. Reference Replacement Models

Same-brand Upgrades / Replacements

ModèleCapacité de coupureType de voyageApplication
T6V 800 PR222DS-LSIG120kA@400VWith earth fault protection (G)Systems requiring earth fault detection
T6V 800 PR223DS120kA@400VAdvanced intelligent trip unitApplications requiring remote monitoring and communication
T6S 800 PR221DS70kA@400VStandard breaking capacityGeneral industrial power distribution, lower cost

Alternatives multimarques

MarqueModèleParamètres de correspondance clés
SchneiderMasterpact MT25H1 800A800UN, 120kA breaking, three-stage protection
Siemens3WL1210-3BB36-4GA4800UN, 100kA breaking, intelligent trip unit
MitsubishiNF800-SEW800UN, 100kA breaking, electronic trip unit
  1. Notes de sélection
  2. Breaking capacity matching: Select V/S/H/N/L classes based on system short-circuit current calculation
  3. Protection function selection: Basic LS/I meets most needs; choose LSIG for earth fault protection
  4. Mounting type: Fixed for standard switchgear, draw-out for easy maintenance and replacement
  5. Accessory configuration: Select auxiliary contacts, alarm contacts, motor operators, etc., according to control requirements
  6. Voltage compatibility: T6V suitable for systems up to 690V; use dedicated 1000V series (par ex., T6L) for higher voltages