ABB SACE EMAX E3H3200-PR123-P-LSIG Air Circuit Breaker - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

disjoncteur/

ABB SACE EMAX E3H3200-PR123-P-LSIG Air Circuit Breaker

Standard designation: E3H 3200 R3200 PR123/P-LSIG an air circuit breaker from ABB’s SACE EMAX series, frame size E3H. Model Segment Description E3H Frame designation (E3 = 3200A frame, H = high breaking capacity) 3200 Frame rated current (3200UN) R3200 Trip unit rated current (3200UN) PR123/P Intelligent trip unit (PR123/P is high-end type with LCD display) ...

  • Détails du produit

Standard designation: E3H 3200 R3200 PR123/P-LSIG an disjoncteur pneumatique from ABB’s SACE EMAX series, frame size E3H.

Segment de modèleDescription
E3HFrame designation (E3 = 3200A frame, H = high breaking capacity)
3200Frame rated current (3200UN)
R3200Trip unit rated current (3200UN)
PR123/PIntelligent trip unit (PR123/P is high-end type with LCD display)
LSIGProtection configuration (L=overload, S=short-time delay, I=instantaneous, G=ground fault)
-P.Mounting type (P = withdrawable, F = fixed)

Global Order Code: 1SDA060849R1 (withdrawable) / 1SDA056503R1 (fixed)

Trade Description: ABB SACE EMAX E3H 3200A 3P/4P LSIG Intelligent Air Circuit Breaker

  1. Key Technical Specifications
ArticleValeurRemarques
Taille du cadreE3 (3200UN)Max rated current up to 3200A
Rated Operational Current (Dans)3200UNWith PR123/P-LSIG trip unit
Tension d'isolation nominale (Interface utilisateur)1000V et50/60Hz, three-phase system
Tension de tenue aux impulsions nominale1000VConforme à la CEI 60947-2
Ultimate Short-Circuit Breaking Capacity (ICU)100kA @ 415V ACHigh breaking, arc-free design
Service Short-Circuit Breaking Capacity (Ics)100kA @ 415V AC (100% ICU)Full selective protection
Fonctions de protection4-step LSIG protectionL, S, je, G as defined above
Trip Unit TypePR123/PLCD display, programmable, event logging
MontageWithdrawable (P.) / Fixé (F)Withdrawable allows hot-swap maintenance
Poteaux3P or 4P4P includes neutral pole protection
ConnexionRear horizontal (HR) / Front horizontal (FR) / Vertical (V)Flexible panel integration
Mechanical Endurance20,000 opérationsHigh-reliability design
Electrical Endurance2,000 opérations (at rated short-circuit)Conforme à la CEI 60947-2
Dimensions432×396.5×461mm (withdrawable)Compact footprint
PoidsEnviron. 85kilos (withdrawable)Standard configuration
Ingress ProtectionIP30Dust-resistant, suitable for switchgear
Impulse Withstand Voltage12kVHigh insulation for industrial environments
Température de fonctionnement-25°C à +70°CWide-temperature design
Tension de contrôle220V CA/CC (standard)Optional 110V/24V AC/DC
  1. Applications

This breaker is widely used in industrial and building power distribution systems:

  1. Industrial Main Distribution: Main incomers, substation LV sections, large motor control centers (Centre multicompte)
  2. Bâtiments commerciaux: Main switchboards in shopping malls, hôtels, hospitals for critical loads
  3. Centres de données: UPS I/O, server room main distribution, high-reliability protection
  4. Renewable Energy: PV inverters, wind turbine converters, suitable for high-harmonic environments
  5. Infrastructure: Metro, airports, ports, withstands frequent operation and harsh conditions
  6. OEM Equipment: Large industrial furnaces, rolling mills, marine electrical systems
  7. Principales fonctionnalités

Intelligent Protection: PR123/P-LSIG 4-step protection with precise selectivity to minimize outages

Haute fiabilité: 100kA pouvoir de coupure, arc-free design for personnel and equipment safety

Configuration flexible: Withdrawable/fixed, 3P/4P, multiple terminations for various installations

Smart Monitoring: LCD real-time display, event logging for diagnostics and preventive maintenance

Expandability: Supports PR120/V (voltage monitoring), PR120/K (load control), PR120/D (directional protection)

Communication: Optional Modbus, Profibus, Ethernet/IP for IIoT integration

Eco-certified: RoHS and REACh compliant, low power consumption (<50W control circuit)

  1. Detailed Protection Functions (PR123/P-LSIG)
ProtectionDescriptionAdjustable RangeApplication
Surcharge (L)Temps inverse, prevents overheating0.4–1.0In, 0.1–60sMoteurs, transformateurs, cables
Short-Time Delay (S)Definite/inverse time for selectivity2–10 pouces, 0.05–3sCascaded distribution, no upstream tripping
Instantané (je)No-delay trip for severe faults5–20InEmergency short-circuit protection
Défaut à la terre (G)Detects earth current, shock/fire prevention0.2-0,8 pouces, 0.1–1sPersonnel and insulation safety
Phase Unbalance (U)Monitors phase current difference10%–50% unbalanceThree-phase motor protection
Sous-tension (UV)Detects voltage drop60%–90%Un, 0.1–10sCritical equipment voltage stability
Surtension (OV)Detects overvoltage105%–120%Un, 0.1–10sGrid fluctuation protection
Overtemperature (OT)Internal trip unit thermal protectionFactory setSelf-protection in harsh environments
  1. Alternatives

6.1 ABB Same-Series Alternatives

ModèleCaractéristiquesApplication
E3H 3200 R2500 PR123/P-LSIG2500Un courant nominal3200A frame with lighter load
E3H 3200 R3200 PR122/P-LSIGPR122/P (basic trip unit)Budget-friendly full protection
E3H 3200 R3200 PR123/P-LSIWithout ground fault protectionSystems not requiring earth fault protection
E3N 3200 R3200 PR123/P-LSIGE3N (medium breaking 65kA)Lower short-circuit duty

6.2 Cross-Brand Alternatives

MarqueAlternative ModelMatching Specs
SchneiderMT32H100 LSIG3200UN, 100le, LSIG
Siemens3WL3225-3CB36-4GA03200UN, 100le, LSIG
Commutateur ChangshuCW3-3200/3P 100kA LSIGDomestic high-performance alternative
ChintNA1-3200X-3200M/3PEconomic domestic alternative
  1. Sélection & Notes d'installation
  2. Cadre & Rated Current Match: E3H max 3200A; select trip rating 630A-3200A based on load
  3. Protection Configuration:

LSIG: Full protection for main incomers and critical loads

LSI: Without ground fault for general distribution

LI: Basic overload + instantaneous for feeders

  1. Type de montage:

Withdrawable (P.): For frequent maintenance, online replacement

Fixé (F): Space-limited, low-maintenance sites

  1. Termination:

HR: Connexion arrière

FR: Connexion frontale

V: Vertical for busbar systems

  1. Accessories:

Contacts auxiliaires: Up to 10NO+10NC

Undervoltage release: Loss-of-voltage protection

Shunt trip: Remote tripping

Communication modules: Smart monitoring

  1. Référence de prix (Tax-included, RMB)
ConfigurationGamme de prixRemarques
Withdrawable 3P28,000 - 35,000With PR123/P-LSIG
Withdrawable 4P30,000 - 38,000With neutral protection
Fixed 3P25,000 - 32,000~10% lower than withdrawable
Fixed 4P27,000 - 35,000With neutral protection
Modbus Communication Module2,000 - 3,000Optional extra
  1. Avantages principaux
  2. Full Selectivity: LSIG with precise settings minimizes outage area
  3. Haute fiabilité: 100kA breaking + arc-free design
  4. Smart Monitoring: LCD and event logs for easy diagnostics
  5. Flexible Layout: Multiple mounting, pôle, and connection options
  6. IIoT Ready: Industrial communication for intelligent power management

Complete List of ABB SACE EMAX Series & Cross-Brand Comparison

  1. EMAX Naming Convention & Paramètres de base

1.1 Model Breakdown

Segment de modèleDescriptionExemple
E1/E2/E3/E4/E6/X1Frame size (E1=1600A, E2=2500A, E3=3200A, E4=4000A, E6=6300A, X1=630A)E3H
H/NBreaking class (H=high, N=medium)H
RXXXTrip rated currentR3200
PR121/PR122/PR123Trip unit type (PR123 = high-end with LCD)PR123/P
LSIG/LSI/LIProtection setLSIG
P/FMontageP.

Standard Example: E3H 3200 R3200 PR123/P-LSIG-P

Global Order Code: 1SDA060849R1 (withdrawable) / 1SDA056503R1 (fixed)

1.2 Breaking Capacity Classes

ClasseBreaking Capacity at 400VApplication
N65leGeneral industry & commercial
H100leIndustrie lourde & main distribution
V150leHigh fault current areas (petrochemical, metallurgy)
  1. Full EMAX Model List

2.1 Standard Range (X1/E1/E2/E3/E4/E6)

CadreCourant de trameCurrent RangeBreakingStandard TripProtectionMontageTypical Order Code
X1630UN250–630AN (42le)PR121/PLSIGP/F1SDA052101R1
E11600UN630–1600AN (65le), H (100le)PR122/PLSIGP/F1SDA053101R1
E22500UN1250–2500AN (65le), H (100le)PR122/PLSIGP/F1SDA054101R1
E33200UN1600–3200AN (65le), H (100le), V (150le)PR123/PLSIGP/F1SDA056503R1
E44000UN2000–4000AN (65le), H (100le), V (150le)PR123/PLSIGP/F1SDA058101R1
E66300UN3200–6300AH (100le), V (150le)PR123/PLSIGP/F1SDA060101R1

2.2 Special Application Versions

SuffixeSignificationApplicationExemple
/CCDC dedicatedSolar, wind, energy storageE3H 3200 R3200 PR123/P-LSIG/DC
/VFVFD output ratedInverter side protectionE2H 2500 R2500 PR122/P-LSIG/VF
/LTTLow temp tolerant-40°C à +70°CE1H 1600 R1600 PR122/P-LSIG/LTT
/EEnhanced voltage690–1150V ACE3H 3200 R3200 PR123/P-LSIG/E

2.3 Trip Unit Comparison

Trip UnitCaractéristiquesAfficherLogCommApplication
PR121/PBasic LI/LSIDIRIGÉ10 eventsAucunSimple distribution
PR122/PStandard LSIGDIRIGÉ20 eventsModbus optionalGeneral industry
PR123/PAdvanced LSIG+LCD100 eventsModbus/ProfibusCritical loads & data centers
  1. ABB EMAX vs Other Brands (Direct Match)

3.1 Full Cross-Brand Table

ABB EMAX ModelFrame/InBreakingProtectionSchneiderSiemensChangshuChint
E1H 1600 R1600 PR122/P-LSIG1600A/1600A100leLSIGMT16H100 LSIG3WL1120-3CB36-4GA0CW3-1600/3P 100kA LSIGNA1-1600X-1600M/3P LSIG
E2H 2500 R2500 PR122/P-LSIG2500A/2500A100leLSIGMT25H100 LSIG3WL1225-3CB36-4GA0CW3-2500/3P 100kA LSIGNA1-2500X-2500M/3P LSIG
E3H 3200 R3200 PR123/P-LSIG3200A/3200A100leLSIGMT32H100 LSIG3WL1332-3CB36-4GA0CW3-3200/3P 100kA LSIGNA1-3200X-3200M/3P LSIG
E4H 4000 R4000 PR123/P-LSIG4000A/4000A100leLSIGMT40H100 LSIG3WL1440-3CB36-4GA0CW3-4000/3P 100kA LSIGNA1-4000X-4000M/3P LSIG
E6H 6300 R6300 PR123/P-LSIG6300A/6300A100leLSIGMT63H100 LSIG3WL1663-3CB36-4GA0CW3-6300/3P 100kA LSIGNA1-6300X-6300M/3P LSIG
E3N 3200 R2500 PR122/P-LSI3200A/2500A65leLSIMT32N100 LSI3WL1325-3CB36-4GA0CW3-3200/3P 65kA LSINA1-3200X-2500M/3P LSI
X1N 630 R630 PR121/P-LI630A/630A42leLIMT06N100 LI3WL1063-3CB36-4GA0CW3-630/3P 42kA LINA1-630X-630M/3P LI

3.2 Key Model Matching (with Order Codes)

ABB CodeModèle completSchneider CodeSiemens CodeMatch Specs
1SDA056503R1E3H 3200 R3200 PR123/P-LSIG-FLV432630 (MT32H100)3WL1332-3CB36-4GA03200UN, 100le, LSIG, fixed
1SDA060849R1E3H 3200 R3200 PR123/P-LSIG-PLV432631 (MT32H100)3WL1332-3CB36-4GA13200UN, 100le, LSIG, withdrawable
1SDA054101R1E2H 2500 R2500 PR122/P-LSIG-PLV432531 (MT25H100)3WL1225-3CB36-4GA12500UN, 100le, LSIG, withdrawable
1SDA053101R1E1H 1600 R1600 PR122/P-LSIG-PLV432431 (MT16H100)3WL1120-3CB36-4GA11600UN, 100le, LSIG, withdrawable
1SDA052101R1X1N 630 R630 PR121/P-LI-PLV432031 (MT06N100)3WL1063-3CB36-4GA1630UN, 42le, LI, withdrawable
  1. Sélection & Replacement Guidelines

4.1 Technical Matching Rules

CatégorieMatching PrincipleRemarques
Frame/InDirect match or downsize630A frame cannot exceed 630A
Capacité de coupure≥ system short-circuit currentH-class (100kA+) recommended for industry
ProtectionMatch or upgradeLSIG can replace LSI; not vice versa
MontageSame type preferredWithdrawable can replace fixed; may need cabinet mods
Tension de contrôleIdentical or universal220V AC/DC preferred for flexibility
ConnexionSame orientationFront/rear/vertical must align

4.2 Brand Strength Comparison

MarqueCore StrengthsUtilisation typique
ABB EMAXUp to 150kA breaking, PR123 smart trip, arc-free, 30,000 mech cyclesCritical loads, data centers, heavy industry
Schneider MTMultiple breaking levels, Micrologic precision, modular, global supportCommercial, OEM, renewables
Siemens 3WL690V rated, surge protection, thermal-magnetic options, full commsInfrastructure, rail, petrochemical
Changshu CW330–40% lower cost, form-fit compatible, domestic supplyCost-sensitive projects
Chint NA1Ultra-economical, full LSIG option, simple maintenanceRésidentiel, light industry, rural grids

4.3 Référence de prix (Tax-included, RMB)

CadreABB EMAXSchneider MTSiemens 3WLChangshu CW3Chint NA1
630UN8,000–12,0007,500–11,0008,500–12,5004,000–6,0003,000–5,000
1600UN15,000–22,00014,000–20,00016,000–23,0008,000–12,0006,000–10,000
3200UN28,000–35,00027,000–34,00029,000–36,00015,000–20,00012,000–18,000
6300UN50,000–65,00048,000–62,00052,000–68,00028,000–38,00025,000–35,000
  1. Recommandations de sélection
  2. Critical Loads: Use ABB EMAX or Schneider MT with PR123/Micrologic trips
  3. Cost Efficiency: 630A-1600A → Changshu CW3 or Chint NA1
  4. Cross-Brand Replacement:

630A-3200A: Direct form-fit replacement

4000A+: Consult manufacturer for cabinet compatibility

  1. Upgrades:

Replace old ACBs (ME/DW15) with EMAX/MT/3WL

Add communication for smart power management