ABB XT2N160 TMA 160 3p-F-F - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

disjoncteur/

ABB XT2N160 TMA 160 3p-F-F

DimensionValeur
Width90
Height130
Depth82.5
Mounting hole spacing75
Terminal spacingStandard
Poids1.574
Package size145*130*208
Package weight1.2

  • Détails du produit

ABB XT2N160 TMA 160 3p F F

Order No.: 1SDA061805R1 (1SDA067020R1)

Full Model: XT2N 160 TMA 160-1600 3p F F

Série: ABB Tmax XT Series Molded Case Circuit Breaker

  1. Core Parameters Summary
Catégorie de paramètreDetailed SpecificationsRemarques
Informations de base• Frame size: XT2For low-voltage power distribution in industry and buildings
• Frame current: 160UN
• Rated current In: 160UN
• Poles: 3P.
• Breaking capacity: Type N (36kA @ 415V AC)
• Rated operating voltage Ue: 690V et, 500À DC
• Standards: CEI 60947-2, FR 14048.2
Trip System• Trip type: TMA thermal-magnetic (surcharge + protection contre les courts-circuits)Not suitable for earth fault protection; additional accessories required
• Overload protection (Ir): Réglable, 160UN
• Short-circuit protection (I3): Réglable, 800~1600A
• Instantaneous short-circuit protection: Fixed at 10In (1600UN)
• Protection curve: Conforme à la CEI 60947-2
Montage & Connection• Mounting type: Fixé (F)Standard DIN rail or screw mounting
• Connection: Front connection (F)
• Operation: Direct handle operation
• Dimensions: 90mm×130mm×82.5mm
• Weight: approx. 1.574kilos
• Protection degree: IP20
Caractéristiques électriques• Rated insulation voltage Ui: 800VSuitable for AC-1, AC-2, AC-3, AC-4 duties
• Rated impulse withstand voltage Uimp: 8kV
• Rated short-time withstand current Icw: 16kA/1s
• Rated frequency: 50/60Hz
• Wiring capacity: maximum. 95mm² copper, maximum. 70mm² aluminum
  1. Detailed Protection Characteristics

2.1 Protection contre les surcharges (Thermal)

Caractéristiques: Inverse time curve per IEC 60947-2

Adjustable range: 160UN (fixed)

Trip time:

1.05Dans: No trip for long duration

1.3Dans: Trip within ≤1 hour

6Dans: Trip within 2~10 seconds

2.2 Protection contre les courts-circuits (Magnetic)

Instantaneous trip: 800~1600A adjustable (I3)

Short-time delay: Not available (TMA has no short-time delay; TMD or electronic trip required)

Instantaneous short-circuit protection: Fixed at 10In (1600UN), non-adjustable

  1. Mounting Dimensions & Caractéristiques physiques
DimensionValeurUnit
Width90mm
Height130mm
Depth82.5mm
Mounting hole spacing75mm
Terminal spacingStandardmm
Poids1.574kilos
Package size145*130*208mm
Package weight1.2kilos

Mounting Requirements:

35mm standard DIN rail (EN 60715) recommandé

Température ambiante: -25°C ~ +70°C

Altitude: ≤2000m (derating required above)

Protection: IP20 (front); must be installed in enclosure with IP30 or higher

  1. Remplacement & Extended Models in the Same Series

4.1 Direct Replacement Models

ModèleDifferenceApplication
XT2N160 TMA 160 3P F FIdentical specificationsRemplacement direct, no modification needed
XT2N160 TMA 160 3P P FPlug-in mounting (P.)Frequent replacement or maintenance
XT2N160 TMA 160 3P F WRear connection (W)Limited cabinet space

4.2 Function-Extended Models

ModèleFunctional UpgradeOrder No.
XT2N160 Ekip LSI 160 3P F FElectronic trip, LSI protection1SDA067071R1
XT2N160 Ekip LSIG 160 3P F FElectronic trip, LSIG protection (including earth fault)1SDA067072R1
XT2N160 TMD 160 3P F FThermal-magnetic with short-time delay1SDA067035R1

4.3 Pole-Extended Models

4P version: XT2N160 TMA 160 4p F F (Order No.: 1SDA061806R1 / 1SDA067041R1)

Neutral pole rated current: 50% ou 100% of phase current optional

4.4 Cross-Brand Reference

Schneider: NSX160N TMD160 3P F

Siemens: 3VT8116-1AA03-0AA0

Chint: NM1-160S/3300 160A

  1. Recommended Accessories
Accessory TypeModèleDescription
Contact auxiliaireXT2-AS111NON + 1Caroline du Nord, for status indication
Alarm contactXT2-AL111NON + 1Caroline du Nord, for fault alarm
Shunt tripXT2-SHTRemote tripping, AC/DC 220V
Undervoltage releaseXT2-UVTProtection contre les sous-tensions, C.A. 220 V
Rotary handleXT2-CRDoor-mounted operation, improved safety
Extended rotary handleXT2-CREFor deep panels
Terminal coverXT2-TCProtect terminals, prevent electric shock
Label holderXT2-LBFor marking breaker parameters
  1. Applications & Notes de sélection

6.1 Applications typiques

Industrial plants: Motor protection (≤160A), distribution feeder protection

Commercial buildings: CVC, éclairage, contrôle de la pompe

Infrastructure: Small substations, data centers, PV systems

Others: OEM equipment, agricultural machinery, marine systems

6.2 Guide de sélection

RequirementRecommandéNot Recommended
Motor protection (with proper setting)Petits moteurs (<10UN); use MCB instead
Distribution protection (sub-circuits)Main incomer (use XT3/XT4 series)
Earth fault protection (needs accessories) (choose Ekip LSIG)
Frequent operation (MCCB not suitable) (contacteur + relais)
Fonction d'isolement (CEI 60947-3)

6.3 Selection Cautions

  1. Ensure rated current In matches load
  2. Breaking capacity must meet system short-circuit current (N: 36kA @ 415V)
  3. Montage (fixed/plug-in) and connection (front/rear) must match panel design
  4. Auxiliaries, shunt/undervoltage trips ordered separately
  5. Not for DC short-circuit protection (use DC-rated model)
  6. Troubleshooting & Entretien

7.1 Défauts courants & Solutions

SymptomCauses possiblesSolutions
Déclenchements fréquents1. Surcharge1. Check load
2. Short circuit2. Locate short circuit
3. Incorrect trip setting3. Reset settings
4. Température ambiante élevée4. Improve ventilation
Cannot close1. No power to undervoltage trip1. Check control power
2. Shunt trip not reset2. Reset shunt trip
3. Mechanism fault3. Contact ABB service
4. Line fault4. Clear fault
No output after closing1. Main contacts damaged1. Inspect/replace contacts
2. Câblage lâche2. Serrer les bornes
3. Trip unit fault3. Replace trip unit
Aux contact no signal1. Auxiliary contact defective1. Replace auxiliary contact
2. Wrong wiring2. Check wiring
3. Improper switching3. Adjust contact position

7.2 Recommandations d'entretien

Inspection: Every 6 months – check wiring and mechanism

Cleaning: Every 12 months – remove dust to maintain insulation

Operation test: Once per year – 3~5 manual ON/OFF cycles

Trip test: Once every 2 years – simulate overload and short circuit

Service life: Typiquement 10 années, depending on duty and environment

  1. Ordering & Packaging

Standard package: 1 unit/box, including installation manual and certificate

MOQ: 1 unit

Warranty: 18 months from commissioning, ou 24 months from delivery (whichever comes first)

Order code: 1SDA061805R1 (or 1SDA067020R1, varies by region)

Complete Model Guide for ABB Tmax XT2 Series (160A Frame)

Frame size: XT2 (160UN)

Tension nominale: 690V et, 500À DC

Poteaux: 3P. / 4P.

Breaking classes: N(36le), S(50le), H(70le), L(100le)

  1. Model Naming Convention

XT2 [Breaking Class] [Courant de trame] [Type de voyage] [Current Range] [Poteaux] [Montage] [Connection]

Breaking class:

N: 36kA @ 415V (standard)

S: 50kA @ 415V (enhanced)

H: 70kA @ 415V (high performance)

L: 100kA @ 415V (ultimate)

Frame current: 160 (fixed)

Trip type:

TMA: Thermal-magnetic (surcharge + instantaneous, no short-time delay)

TMD: Thermal-magnetic (surcharge + short-time delay + instantaneous)

Ekip LSI: Electronic (surcharge + short-time delay + instantaneous)

Ekip LSIG: Electronic (surcharge + short-time delay + instantaneous + earth fault)

Ekip I: Electronic (instantaneous only)

Plage actuelle: par ex., 160-1600 (TMA 160A)

Poteaux: 3P. / 4P.

Montage: F (Fixé) / P. (Plug-in)

Connection: F (Front) / W (Rear)

  1. XT2 Series Model List (by Breaking Class)

2.1 Standard Breaking (N, 36le)

Model PrefixType de voyageModèle typiqueCurrent RangeApplication
XT2N160TMAXT2N160 TMA 160-1600 3P F F160UNGeneral distribution, moteurs
TMDXT2N160 TMD 100-1000 4P F W100UNSystems requiring short-time delay
Ekip LSIXT2N160 Ekip LSI R125 3P P F125UNElectronic protection, remote monitoring
Ekip LSIGXT2N160 Ekip LSIG R80 4P F F80UNEarth fault protection required

Example Order No.: 1SDA061805R1 (XT2N160 TMA 160 3P F F)

2.2 Enhanced Breaking (S, 50le)

Model PrefixType de voyageModèle typiqueCurrent RangeApplication
XT2S160TMAXT2S160 TMA 63-630 3P F F63UNIndustrie, heavy-duty equipment
TMDXT2S160 TMD 40-400 4P P W40UNFrequently started motors
Ekip LSIXT2S160 Ekip C Dip LSI R100 3P F F100UNComplex commercial distribution
Ekip LSIGXT2S160 Ekip LSIG R50 4P F F50UNData centers, medical facilities

Example Order No.: 1SDA067021R1 (XT2S160 TMA 160 3P F F)

2.3 High Performance Breaking (H, 70le)

Model PrefixType de voyageModèle typiqueCurrent RangeApplication
XT2H160TMAXT2H160 TMA 32-320 3P F F32UNIndustrial systems with high short-circuit current
TMDXT2H160 TMD 3.2-32 4P F F3.2UNPrecision equipment, control circuits
Ekip LSIXT2H160 Ekip Dip LSI R63 3P P F63UNGenerators, substations
Ekip LSIGXT2H160 Ekip LSIG R25 4P F F25UNPV, renewable energy

Example Order No.: 1SDA067587R1 (XT2H160 TMD 3.2-32 3P F F)

2.4 Ultimate Breaking (L, 100le)

Model PrefixType de voyageModèle typiqueCurrent RangeApplication
XT2L160TMAXT2L160 TMA 100-1000 4P F F100UNHeavy industry with very high fault level
TMDXT2L160 TMD 160-1600 3P F W160UNLarge motor control centers
Ekip LSIXT2L160 Ekip LSI R160 3P P F160UNMetallurgy, chemical, hazardous areas
Ekip LSIGXT2L160 Ekip LSIG R125 4P F F125UNPetrochemical, mining

Example Order No.: 1SDA067667R1 (XT2L160 TMA 100-1000 4P F F)

  1. Trip Unit Comparison
Type de voyageProtectionAdjustable ParametersTypical LoadPrice Level
TMASurcharge + InstantanéIr, I3Moteurs, distribution généraleEconomy
TMDSurcharge + Short-time + InstantanéIr, Isd, tsd, I3Transformers, condensateursMedium
Ekip LSISurcharge + Short-time + InstantanéFull range, communicationCritical distributionMedium-High
Ekip LSIGSurcharge + Short-time + Instantané + Earth FaultFull range, communication, loggingSensitive loads, safetyHigh
Ekip IInstantaneous onlyI3Short-circuit intensive devicesEconomy
  1. Modèles spéciaux & Options

4.1 4P Neutral Configurations

Standard: Neutral = 50% phase (distribution générale)

Heavy: Neutral = 100% phase (non-linear loads: VFD, UPS)

Exemple: XT2N160 TMA 160 4P F F (100% neutral)

4.2 Plug-in Mounting (P.)

Fast replacement, adapté aux équipements critiques

Exemple: XT2S160 TMD 80 3P P F

4.3 Rear Connection (W)

Saves cabinet space, compact panels

Exemple: XT2H160 Ekip LSI R63 3P F W

4.4 Compatibilité des accessoires (Full Series)

AccessoireModèleDescription
Contact auxiliaireXT2-AS111NON+1NC, status indication
Alarm contactXT2-AL111NON+1NC, fault alarm
Shunt tripXT2-SHTRemote tripping, AC/DC 220V
Undervoltage releaseXT2-UVTProtection contre les sous-tensions, C.A. 220 V
Rotary handleXT2-CRDoor operation, safety
  1. Quick Selection Table
ApplicationRecommended ClassType de voyagePoteauxMount/Conn
General industrialN/STMA/TMD3P.F/F
Motor protectionN/STMA3P.F/F
Commercial lightingNTMA3P/4PF/F
Data centerH/LEkip LSIG4P.F/W
PV systemH/LEkip LSIG4P.F/F
Frequent maintenanceAnyAny3P/4PP/F
  1. Remplacement & Upgrade Path

6.1 Same-Frame Upgrade

Pouvoir de coupure: XT2N → XT2S → XT2H → XT2L (dimensions unchanged)

Trip unit: TMA → TMD → Ekip LSI → Ekip LSIG

Mount/connection: F/F → P/F or F/W

6.2 Cross-Frame Upgrade

XT2 (160UN) → XT3 (250UN) → XT4 (250A enhanced) → XT5 (630UN)

Note dimension and parameter changes

All XT2 series models comply with IEC 60947-2 and GB 14048.2.

Fixed dimensions: 90mm × 130mm × 82.5mm for easy system expansion and maintenance.