The Chint NH402000/4SZ is a PCclass Automatic Transfer Switching Equipment (ATSÉ), specifically designed for threephase fourwire power supply systems, and is suitable for scenarios with extremely high requirements for power supply continuity. The following is a detailed analysis of its core technical parameters, application scenarios, et suggestions de sélection:Prix des disjoncteurs Schneider
- Core Technical Parameters and Functional Characteristics
- Performances électriquesChint’s NB163DC series DC circuit breakers Prix
Courant nominal: 2000UN, which can stably carry large current loads for a long time, suitable for scenarios such as industrial equipment and large commercial buildings.
Tension nominale: Alternating current 50Hz/60Hz, with a rated operating voltage of 400V or 690V (to be confirmed according to the model).
Capacité de coupurePrix des relais de surcharge thermique série Chint NXR:
Shorttime withstand current (Icw): According to the technical documents of the Chint NH40 series, the Icw of large current models (such as 630A) is 12.6kA. It is speculated that the Icw of the 2000A model may be higher (subject to the official parameters).CHINT contactor price
Shortcircuit making capacity (Icm): Généralement 1.8 times that of Icw. Par exemple, the Icm of the 630A model is 25.2kA, and the 2000A model may reach a higher value.
Normes de certification: It complies with GB/T 14048.11 (corresponding to IEC 6094761) and GB/T 14048.3 (corresponding to IEC 609473) normes, but UL certification is not explicitly mentioned, which may affect its use in the North American market.
- Structure and OperationPrix du parasurtenseur CHINT
Pole Number and Conversion Mode: 4P fourpole design, supporting automatic or manual switching between two power sources (main power source and backup power source). There will be a short interruption of power supply during the switching process (the conversion time is about 0.10.5 secondes).
Drive Mode: Electromagnetic drive. The operating mechanism has a builtin energy storage spring to ensure fast and reliable switching.
Méthode d'installation: It supports frontofpanel wiring. The operating handle can be installed inside or outside the cabinet, adapting to different distribution cabinet designs.
- Scénarios d'application typiques
- Key Infrastructure
Hospitals: Backup power source switching in places such as operating rooms and Intensive Care Units (ICUs) to ensure the continuous operation of medical equipment.
Data Centers: Power supply guarantee for server clusters and network equipment to avoid data loss or service interruption due to power outages.
Systèmes de protection incendie: Power source switching for equipment such as fire pumps and emergency lighting to meet fire protection specification requirements.
- Industrial and Commercial Fields
Chemical/Metallurgical Industries: Power supply for motors and control systems on production lines to prevent production accidents caused by power outages.
Highrise Buildings: Dualpower supply guarantee for elevators, water supply and drainage systems, and security equipment to enhance building safety.
Malls/Supermarkets: Power source switching for cash register systems and cold storage equipment to reduce losses due to business interruptions.
- Emergency and Backup Power Sources
Military Facilities: Backup power source switching for communication equipment and command systems to ensure the reliability of power supply during wartime.
Civil Air Defense Projects: Power supply guarantee for underground shelters and emergency command centers to meet disaster prevention needs.
III. Selection and Installation Key Points
- Correspondance de charge
Current Selection: Ensure that the rated current of the switch (2000UN) is greater than the actual load current. It is recommended to reserve a 20%30% redundancy.
Shortcircuit Protection: The PCclass switch itself does not have shortcircuit breaking capacity and needs to be used in conjunction with a circuit breaker (such as the Chint NM8 series molded case circuit breaker) to achieve the breaking of fault current.
- Exigences environnementales
Temperature and Altitude: The operating temperature is from 5°C to +40°C, and the altitude should not exceed 2000 mètres. In highaltitude areas, it needs to be derated for use.
Humidity and Pollution: When the maximum temperature is +40°C, the relative humidity should not exceed 50%. At lower temperatures, a higher humidity is allowed (tel que 90% at 20°C), but protection against condensation is required.
Emplacement d'installation: It should be vertically installed in a place without vibration and corrosive gases, and avoid direct sunlight.
- Certification et conformité
Marché nord-américain: If it needs to be used in North America, it is necessary to confirm whether it has passed the UL certification (currently not mentioned in the public information), or select an alternative model with UL certification (such as the Schneider CVS series).
Fire Protection Requirements: When used in a fire protection system, it needs to comply with the relevant requirements of GB 50116 “Code for Design of Automatic Fire Alarm Systems”.
- Price and Supply Information
- Market Price
NH402000/4SZ: Consult via Whatsapp: 8613811255435
- État de l'approvisionnement
Regular Models: Medium and low current models (such as 63A, 100UN) usually have现货 and can be delivered quickly.
2000A Model: It may need to be customized or have a long delivery cycle (about 24 semaines). It is recommended to confirm the inventory and production plan with the supplier in advance.
- Maintenance and Troubleshooting
- Entretien quotidien
Inspection régulière: Inspect the contact state of the contacts, the tightness of the wiring terminals, and the flexibility of the operating mechanism every quarter.
Nettoyage et entretien: Remove dust and oil stains to ensure the insulation performance of the housing. When the contacts are oxidized, they need to be sanded with sandpaper or replaced.
Function Test: Conduct an automatic switching test once a year to verify the reliability of the control circuit and the drive motor.
- Common Faults and Handling
Switching Failure: Check whether the power supply voltage, control signal, and drive motor are normal. Replace the control module if necessary.
Contact Overheating: Check whether the load current exceeds the rated value, or if the contact pressure is insufficient, adjust the spring tension.
Malfunction: Check for electromagnetic interference or control logic errors, and adjust the delay parameters or upgrade the firmware.
Alternative Solutions and Comparisons
- Internal Alternatives of Chint
NZ7 Series: It has a higher breaking capacity (Icw can reach up to 80kA), suitable for scenarios with higher requirements for shortcircuit protection, but the price is about 30%50% higher than that of the NH40SZ series.
NTS Series: An economical dualpower conversion switch with a lower price but simplified functions, suitable for noncritical loads.
- Other Brands
Schneider CVS Series: It supports UL certification and has a strong breaking capacity (Icw up to 150kA), but the price is about 23 times that of the NH40SZ series.
ABB Tmax XT Series: Conception modulaire, with expandable communication functions, suitable for intelligent power distribution systems.
Conclusion
The NH402000/4SZ is a highly reliable dualpower conversion switch, suitable for industrial, commercial, and infrastructure scenarios with extremely high requirements for power supply continuity. Lors de la sélection d'un modèle, key attention should be paid to load matching, breaking capacity, and certification requirements, and the latest technical support should be obtained through official channels. If you need to further understand the detailed parameters of the 2000A model or its applicability in the North American market, it is recommended to directly contact the Chint sales team or authorized dealers.
Recommendations for alternative solutions for Chint NH402000/4SZ (PCclass automatic transfer switch for dual power supplies, rated current 2000A, four poles), covering domestic brands, international brands, and models suitable for special scenarios, along with selection suggestions and certification instructions:
- Alternative Solutions from Domestic Brands
- Delixi CDQ3H Series (PCclass ATSE)
Paramètres de base:
Courant nominal: 2000UN (Needs customization, the highest rated current of regular models is 800A)
Capacité de coupure: Icw = 12.6kA (Reference value for the 630A model), it is speculated that the 2000A model is higher
Attestation: CCC certification, UL certification is not explicitly mentioned
Avantages:
The price is about 80%90% of that of the Chint NH40 series, with high costeffectiveness.
Supports automatic/manual switching and is suitable for threephase fourwire systems.
Scénarios applicables: Backup power supply switching for domestic industrial and commercial buildings, and scenarios with low requirements for certification.
Prix de référence: Consult via Whatsapp: 8613811255435 yuan (Needs customization, subject to the quotation of dealers).
Delivery Cycle: Regular models are in stock, and the 2000A model requires 34 semaines.
- People’s Electric Appliance RQ3 Series (PCclass ATSE)
Paramètres de base:
Courant nominal: 2000UN (Needs customization, the highest rated current of regular models is 1600A)
Capacité de coupure: Icw = 12.6kA (Reference value for the 630A model)
Attestation: CCC certification, UL certification is not explicitly mentioned
Avantages:
It has high interface compatibility with the Chint NH40 series, making it easy for direct replacement.
Supports the fire protection linkage function and complies with the GB 50116 standard.
Scénarios applicables: Scenarios with strict fire protection requirements such as domestic hospitals and data centers.
Prix de référence: Consult via Whatsapp: 8613811255435 (Customized model).
Delivery Cycle: Requires 46 semaines.
- Nader NDQ3 Series (PCclass ATSE)
Paramètres de base:
Courant nominal: 2000UN (Needs customization, the highest rated current of regular models is 1600A)
Capacité de coupure: Icw = 12.6kA (Reference value for the 630A model)
Attestation: CCC certification, UL certification is not explicitly mentioned
Avantages:
Conception modulaire, supports the expansion of communication interfaces (such as Modbus).
Has a relatively high shorttime withstand current, suitable for scenarios with high shortcircuit currents.
Scénarios applicables: Scenarios that require communication functions such as industrial automation and smart grids.
Prix de référence: Consult via Whatsapp: 8613811255435 (Customized model).
Delivery Cycle: Requires 35 semaines.
- Alternative Solutions from International Brands
- Schneider CVS Series (PCclass ATSE)
Paramètres de base:
Courant nominal: 2000UN (Needs customization, the highest rated current of regular models is 1600A)
Capacité de coupure: Icw = 50kA (For the 1600A model)
Attestation: UL certification (Applicable in the North American market), CE certification
Avantages:
Has UL certification, suitable for the North American market.
Has a strong breaking capacity and can directly replace the NH40SZ series without the need for an additional circuit breaker.
Scénarios applicables: Multinational enterprises, data centers, hospitals, etc.. in the North American region.
Prix de référence: Consult via Whatsapp: 8613811255435 (Customized model).
Delivery Cycle: Requires 68 semaines (Import cycle).
- ABB Tmax XT Series (PCclass ATSE)
Paramètres de base:
Courant nominal: 2000UN (Needs customization, the highest rated current of regular models is 1600A)
Capacité de coupure: Icw = 50kA (For the 1600A model)
Attestation: UL certification, CE certification
Avantages:
Supports hotswappable modules, making maintenance convenient.
Integrates intelligent monitoring functions and can be managed remotely.
Scénarios applicables: Highend commercial buildings, intelligent manufacturing factories.
Prix de référence: Consult via Whatsapp: 8613811255435 (Customized model).
Delivery Cycle: Requires 57 semaines (Import cycle).
- Siemens 5SX Series (PCclass ATSE)
Paramètres de base:
Courant nominal: 2000UN (Needs customization, the highest rated current of regular models is 1600A)
Capacité de coupure: Icw = 50kA (For the 1600A model)
Attestation: UL certification, CE certification
Avantages:
Conforme à la CEI 61850 standard and supports power system integration.
Seismic design, adapté aux environnements difficiles.
Scénarios applicables: Special environments such as petrochemical and offshore platforms.
Prix de référence: Consult via Whatsapp: 8613811255435 (Customized model).
Delivery Cycle: Requires 710 semaines (Import cycle).
III. Solutions Suitable for Special Scenarios
- Scenarios with High Shortcircuit Currents (such as metallurgy, chemical industry)
Modèle recommandé: Chint NZ7 Series (CBclass ATSE)
Paramètres de base:
Courant nominal: 2000UN (Needs customization)
Capacité de coupure: Icw = 80kA
Attestation: CCC certification
Avantages:
The CB class has shortcircuit breaking capacity and does not require an additional circuit breaker.
The breaking capacity is more than 6 times that of the NH40SZ series.
Prix de référence: Consult via Whatsapp: 8613811255435 (Customized model).
- Marché nord-américain (Requires UL Certification)
Modèle recommandé: Eaton ASCO Series (PCclass ATSE)
Paramètres de base:
Courant nominal: 2000UN (Regular model)
Capacité de coupure: Icw = 50kA
Attestation: UL certification, CSA certification
Avantages:
High market share in the North American market and perfect technical support.
Supports synchronous switching of dual power supplies, reducing power outage time.
Prix de référence: Consult via Whatsapp: 8613811255435 yuan.
- Selection Suggestions and Certification Instructions
- Prior Selection for Domestic Scenarios:
Costeffectiveness: Delixi CDQ3H series (Low price, fast supply).
Fire Protection Requirements: People’s Electric Appliance RQ3 series (Supports fire protection linkage).
Intelligence: Nader NDQ3 series (Supports communication expansion).
- Mustchoose for the North American Market:
Schneider CVS series, ABB Tmax XT series (Both have passed UL certification).
- High Reliability Requirements:
International brands (such as Siemens, Eaton) have better breaking capacity and certification.
- Certification Precautions:
Domestique: It is necessary to confirm the CCC certification (Essential).
North America: It is necessary to have UL certification (Some models require cCSAus dual certification).
Europe: It is necessary to have CE certification (International brands have it by default).
- Comparison Table of Alternative Solutions
| Brand/Model | Courant nominal | Capacité de coupure (Icw) | Attestation | Gamme de prix (Yuan) | Delivery Cycle | Scénarios applicables |
| Delixi CDQ3H2000/4P | 2000UN | 12.6le (Speculated) | CCC | WhatsApp: 8613811255435 | 34 semaines | Domestic industrial and commercial buildings |
| People’s Electric Appliance RQ32000/4P | 2000UN | 12.6le (Speculated) | CCC | WhatsApp: 8613811255435 | 46 semaines | Hospitals, data centers (Fire protection requirements) |
| Nader NDQ32000/4P NDQ32000/4P | 2000UN | 12.6le (Speculated) | CCC | WhatsApp: 8613811255435 | 35 semaines | Industrial automation, smart grids |
| Schneider CVS2000/4P | 2000UN | 50le | UL/CE | WhatsApp: 8613811255435 | 68 semaines | Marché nord-américain, multinational enterprises |
| ABB Tmax XT2000/4P | 2000UN | 50le | UL/CE | WhatsApp: 8613811255435 | 57 semaines | Highend commercial buildings, intelligent manufacturing |
| Siemens 5SX2000/4P | 2000UN | 50le | UL/CE | WhatsApp: 8613811255435 | 710 semaines | Petrochemical, offshore platforms |
| Eaton ASCO2000/4P | 2000UN | 50le | UL/CSA | WhatsApp: 8613811255435 | 812 semaines | Marché nord-américain, highreliability scenarios |
- Procurement and Technical Support Suggestions
- Parameter Confirmation:
Require the supplier to provide detailed parameters of the 2000A model (such as Icw, Icm, switching time) to ensure a match with the NH40SZ series.
For domestic brands, it is necessary to confirm whether the breaking capacity meets the load shortcircuit current, and use it in conjunction with a circuit breaker if necessary.
- Certification Documents:
Pour le marché nord-américain, it is necessary to provide a UL certification certificate, and for the European market, it is necessary to provide CE certification.
- Compatibilité d'installation:
Confirm that the installation dimensions and wiring methods (frontofpanel/rearofpanel) match the original distribution cabinet.
- Aftersales Service:
International brands (such as Schneider, ABB) provide global warranty, and for domestic brands, it is necessary to confirm the local service outlets.
- Emergency Procurement:
Domestic brands (such as Delixi, People’s Electric Appliance) usually have inventory of large current models, which can shorten the delivery cycle.
It is recommended to first contact the authorized dealer of Chint to confirm the supply status of NH402000/4SZ. If the demand cannot be met, then select a model according to the above alternative solutions. For complex scenarios (such as high shortcircuit currents, the North American market), you can contact the technical teams of brands such as Schneider and ABB to provide customized solutions.
Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires