Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

Chint NBP125-2P/80A Circuit Breaker - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

disjoncteur/

Chint NBP125-2P/80A Circuit Breaker

ModèleParamètres de baseCaractéristiques fonctionnelles
NBP-125NZS/2P 80AFrame current 125A, 2P., 80UN, AC 230V, 50HZOriginal same-series product; supports prepaid fee control, remote tripping, automatic closing after fee recharge, as well as overload and short-circuit protection
NBP-100NZS/2P 80AFrame current 100A, 2P., 80UN, AC 230V, 50HZSame series with reduced frame current; identical functions and compatible installation dimensions
NBP-80NZSY/2P 80AFrame current 80A, 2P., 80UN, AC 230V, 50HZStandard model of the same series; complete fee control functions; DIN rail mounting

  • Détails du produit

The Chint NBP125-2P/80A is a type of disjoncteur manufactured by Chint Electric.

Interprétation du modèle: “Chint” is the English brand name of Chint Group. Dans “NBP125”, “NBPis likely the series code for Chint’s specific circuit breaker line; “125” indicates the rated frame current is 125A, meaning the maximum current the breaker’s frame can withstand stably is 125A. “2P.” stands for 2 poles, qui peut contrôler simultanément le fil sous tension et le fil neutre. “80UN” refers to the rated current of 80A, representing the maximum current the circuit breaker can carry safely and stably for a long period.

Caractéristiques fonctionnelles: This model is an external circuit breaker for electricity meters. It is suitable for AC 50Hz circuits with a rated voltage of 230V, offrant une protection contre les surcharges et les courts-circuits. Entre-temps, as a supporting circuit breaker for smart electricity meters, it is equipped with functions of remote control tripping and automatic closing after fee recharge.

Paramètres techniques: It complies with standards such as GB/T 10963.1 and CQC 1121. The pollution degree is Class 2, the protection class is IP20, the installation category is Class II and III, and the ambient air temperature range is -25°C ~ +60°C.

Appearance and Installation: It generally adopts a plastic case structure, featuring small size, light weight and easy installation. It is usually installed on a DIN rail and can be conveniently mounted inside a distribution box.

  1. Chint Same-Series/Same-Function Alternative Models (Optimal Match)
ModèleParamètres de baseCaractéristiques fonctionnellesMatching Degree
NBP-125NZS/2P 80AFrame current 125A, 2P., 80UN, AC 230V, 50HZOriginal same-series product; supports prepaid fee control, remote tripping, automatic closing after fee recharge, as well as overload and short-circuit protection★★★★★
NBP-100NZS/2P 80AFrame current 100A, 2P., 80UN, AC 230V, 50HZSame series with reduced frame current; identical functions and compatible installation dimensions★★★★☆
NBP-80NZSY/2P 80AFrame current 80A, 2P., 80UN, AC 230V, 50HZStandard model of the same series; complete fee control functions; DIN rail mounting★★★★☆
  1. Alternative Models from Other Chint Series (Functionally Compatible)
ModèleParamètres de baseCaractéristiques fonctionnellesMatching Degree
NXB-125(G)/2P 80AFrame current 125A, 2P., 80UN, AC 230V, 50HZChint standard external circuit breaker for electricity meters; supports remote control and automatic reclosing★★★★
NB2-125ZT/2P 80AFrame current 125A, 2P., 80UN, AC 230V, 50HZIntelligent type; equipped with electrical parameter measurement, Communication RS485, and remote switching on/off★★★★

III. Alternative Models from Other Brands (Compatible with State Grid/Southern Power Grid)

ModèleParamètres de baseCaractéristiques fonctionnellesMatching Degree
SCB8ZY-125M/2P 80AFrame current 125A, 2P., 80UN, AC 230V, 50/60HZExternal for electricity meters; remote control; overload and short-circuit protection; compliant with State Grid standards★★★★
YFB1Z-125AP/2P 80AFrame current 125A, 2P., 80UN, AC 230V, 50HZDedicated for prepaid systems; balance-controlled switching on/off; suitable for State Grid and Southern Power Grid systems★★★★
HXLB5N-125Z/2P 80AFrame current 125A, 2P., 80UN, AC 230V, 50/60HZRemote tripping, automatic reclosing, overload and short-circuit protection★★★★
HB020C-125/2P 80AFrame current 125A, 2P., 80UN, AC 230V, 50HZLong-distance automatic switching on/off; overload and short-circuit protection; DIN rail mounting★★★★
KYDB1-80ZFQ/2P 80AFrame current 80A, 2P., 80UN, AC 230V, 50/60HZPrepaid automatic reclosing; balance control; overload and short-circuit protection★★★☆

Key Points for Alternative Model Selection

  1. Functional Matching: Select external circuit breakers for electricity meters that must have the three core functions: remote control tripping, automatic closing after fee recharge—these are the core features of the NBP series.
  2. Parameter Consistency:

Poles: strictly 2P (controlling both live wire and neutral wire at the same time)

Courant nominal: 80UN (long-term operating current)

Frame current rating: ≥ 80A (125A is recommended, consistent with the original model)

Tension nominale: AC 230V (for single-phase fee control applications)

  1. Certification Compliance:

Must have CCC Compulsory Certification and CQC Certification

Comply with the State Grid Technical Specification for External Circuit Breakers of Electricity Meters (Q/GDW 11421-2015)

Pollution degree Class 2, protection class IP20, installation category Class II/III

  1. Compatibilité d'installation:

Standard 35mm DIN rail mounting (consistent with the NBP series)

Width is recommended to be ≤ 36mm (to ensure space compatibility inside the distribution box)

  1. Communication Compatibility:

For network management, select models supporting RS485 communication or power line carrier communication

Communication protocols must be compatible with the State Grid/Southern Power Grid power consumption information collection system

Recommendation Priority

  1. Chint same-series alternatives (NBP-125NZS/2P 80A): Entièrement compatible, no need to adjust any wiring or settings
  2. Other Chint series (NXB-125(G)/2P 80A): Same brand, reliable quality, convenient installation and maintenance
  3. Other brandsState Grid standard models (SCB8ZY-125M/2P 80A): Potentially more cost-effective with fully matching functions

Précédent:

Suivant:

Laisser une réponse

Laisser un message