The Chint NM1-125S/3300-63A Molded Case Circuit Breaker (MCCB) is a high-performance power distribution protection device in the NM1 series of Chint Group (CHNT). It is suitable for power distribution systems with an AC frequency of 50Hz and a rated operating voltage up to 690V, and is mainly used for overload, short-circuit, and under-voltage protection. The following is a detailed analysis based on Chint’s official data and industry standards:
- Core Parameters and Technical Characteristics
- Paramètres de base
Courant nominal (Dans): 63UN, suitable for the load requirements of the circuit.
Frame Current (Inm): 125UN, indicating the maximum current-carrying capacity of the circuit breaker.
Capacité de coupure:
Rated Ultimate Short-Circuit Breaking Capacity (ICU): 35le (at 400V), meeting the safety requirements of medium and high-risk power distribution scenarios.
Rated Service Short-Circuit Breaking Capacity (Ics): 18le, ensuring the circuit breaker can operate reliably after multiple faults.
Numéro de pôle: 3 poles (the first “3” in 3300), applicable to three-phase four-wire or three-phase three-wire systems.
Tripping Characteristics:
Thermomagnetic Release (the second “3” in 3300), with both overload long-time delay (inverse time) and short-circuit instantaneous protection functions.
Inverse Time Operation Characteristics: The conventional non-tripping current is 1.05In (no tripping within 2 heures), the conventional tripping current is 1.30In (tripping within 2 heures), and the instantaneous operation is set to 10In±20%.
- Performances électriques
Tension d'isolation nominale (Interface utilisateur): 800V, supporting the compatibility of high-voltage level systems.
Conformité aux normes: GB/T 14048.2 (equivalent to IEC 60947-2), and has obtained certifications such as CCC, KEMA, and CE, ensuring international versatility and reliability.
- Conception structurelle
Méthode d'installation: Supports vertical or horizontal installation, flexibly adapting to different cabinet layouts.
Méthode de câblage: Câblage du panneau avant (configuration standard); some upgraded models offer plug-in design (par ex., NM1-125S/3300 63A G).
Arc Flash Distance: ≤50mm, reducing the risk of damage to surrounding equipment caused by fault arcs.
- Application Scenarios and Typical Configurations
- Champs d'application
Industrial Power Distribution: Power protection for power equipment such as machine tools and production lines.
Bâtiments commerciaux: Control of distribution boxes and branch circuits in office buildings and shopping malls.
Residential and Small-Scale Infrastructure: Overload protection for indoor main incoming lines or high-power electrical appliances (par ex., climatiseurs, electric water heaters).
- Accessory Expansion
Auxiliary Functions: Can be equipped with a shunt release (pour coupure de circuit à distance), an under-voltage release (for automatic disconnection when voltage is abnormal), or an alarm contact (for fault status signal output) to meet the needs of intelligent control.
Compatibilité d'installation: Accessory modules are universal with other models in the NM1 series, facilitating later function upgrades.
III. Usage and Maintenance Recommendations
- Spécifications d'installation
Exigences environnementales: Ambient air temperature ranges from -5℃ to +40℃, altitude ≤2000m, and strong magnetic field interference should be avoided.
Exigences de câblage: Tighten terminal bolts to the specified torque (se référer au manuel) to ensure reliable contact and prevent overheating.
- Operation and Maintenance Key Points
Inspection régulière: Clean the dust on the housing every six months, check the wear of contacts, and replace them if necessary.
,Dépannage: If frequent tripping occurs, it is necessary to check whether the load exceeds the limit, whether the line is short-circuited, or whether the setting value of the release is reasonable.
- Replacement and Upgrade
New Model Replacement: Since 2021, Chint has launched upgraded platform-type products (models with suffix “G”), such as NM1-125S/3300 63A G. The breaking capacity is increased to 50kA, and the installation dimensions are compatible with the old models, enabling seamless replacement.
Local Procurement: Contact Chint’s authorized distributor via WhatsApp: 0086-13811255435 to obtain spot goods and technical support.
- Key Considerations for Selection
- Matching of Breaking Capacity: Select the corresponding breaking level (par ex., Type S: 35le, Type H: 50le) according to the short-circuit current level to avoid equipment damage due to insufficient selection.
- Adaptation of Tripping Curve: For power distribution scenarios, Tapez C (5-10 times In instantaneous tripping) is preferred; for motor protection, Tapez D (10-14 times In) est requis.
- Certification Compliance: For domestic projects, CCC certification must be confirmed; for export projects, attention should be paid to the standards of the target market (par ex., CE, NOM).
Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires


















NH42-63-318x560.png)