Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

Chint NM1-800H/3300-800A MCCB - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

disjoncteur/

Chint NM1-800H/3300-800A MCCB

CodeSignification
NM1Chint NM1 series molded case circuit breaker
800Frame current 800A
HHigh breaking capacity grade (Grade H, typically 50kA at 400V AC)
33003 poteaux, combined tripper (thermomagnetic tripping), no accessories
800UNRated current 800A

  • Détails du produit

Chint NM1-800H/3300-800A is a 3-pole, 800UN disjoncteur à boîtier moulé (MCCB) of the NM1 series, featuring H-grade breaking capacity and thermomagnetic tripping. It is designed for overload and short-circuit protection of power distribution lines, and suitable for industrial and large commercial power distribution trunk lines.

CodeSignification
NM1Chint NM1 series molded case circuit breaker
800Frame current 800A
HHigh breaking capacity grade (Grade H, typically 50kA at 400V AC)
33003 poteaux, combined tripper (thermomagnetic tripping), no accessories
800UNRated current 800A

Paramètres de base

ParamètreValeur
Rated operating voltageAC 690V, 50HZ
Tension d'isolement nominale800V
Courant nominal800UN
Pouvoir de coupureGrade H: 50le (400V et)
Pole number3P.
Tripper typeThermomagnetic (overload long-time delay + short-circuit instantaneous protection)
Méthode de montageFixed type, vertical/horizontal mounting available
Wiring methodFront wiring (rear wiring and plug-in type optional)
Operation methodDirect handle operation
Executive standardFR 14048.2, CEI 60947-2, Certification CCC

Scénarios d'application

Overload and short-circuit protection for industrial power distribution trunks and power circuits in large workshops.

Protection for power distribution main trunks in commercial buildings (shopping malls, office buildings).

Protection for large motor circuits with infrequent starting.

Installation and Operation Key Points

  1. Installation shall comply with specifications; both vertical and horizontal mounting are acceptable, with secure fastening and good heat dissipation ensured.
  2. Check the specification of wiring terminals before wiring to match cables/bus bars for 800A current.
  3. Regularly inspect the action accuracy of the tripper to avoid the impact of ambient temperature on protection performance.

Cross-brand Replacement Reference

Schneider: NSX 800N/3P 800A (Verify breaking capacity and tripping curve).

ABB: Tmax T6N 800/3P 800A (Pay attention to mounting dimensions and accessory compatibility).

The core difference between Chint NM1-800H/3300-800A and NM1-800H/3200-800A lies in the tripper type and protection function; other basic parameters (frame current, pouvoir de coupure, numéro de pôle, etc.) are completely consistent.

  1. Core Difference: Meaning of “3300” et “3200” in the Model
Model PartDigital MeaningFonction de protection
33001st digit 3 = 3 poteaux; 2nd digit 3 = combined tripper (thermomagnetic tripping); last two digits 00 = no accessoriesOverload long-time delay protection + short-circuit instantaneous protection
32001st digit 3 = 3 poteaux; 2nd digit 2 = magnetic tripper (magnetic tripping only); last two digits 00 = no accessoriesShort-circuit instantaneous protection only, no overload protection

This is the fundamental difference between the two circuit breakers, which directly determines their application scenarios and protection capabilities.

  1. Complete Parameter Comparison Table
ParamètreNM1-800H/3300-800ANM1-800H/3200-800ARemarques
Tripper typeThermomagnetic combined trippingMagnetic trippingCore difference
Protection contre les surcharges Available (long-time delay)UnavailableLe 3300 model achieves overload delay protection through the thermal bending of bimetallic strips
Protection contre les courts-circuitsAvailable (instantaneous)Available (instantaneous)Both realize short-circuit instantaneous tripping through electromagnetic coils
Frame current800UN800UNConsistent
Courant nominal800UN800UNConsistent
Pouvoir de coupureGrade H (50kA@400V AC)Grade H (50kA@400V AC)Consistent
Pole number3P.3P.Consistent
Tension nominaleAC 690V, 50HZAC 690V, 50HZConsistent
Tension d'isolement nominale800V800VConsistent
Méthode de montageFixed type (vertical/horizontal)Fixed type (vertical/horizontal)Consistent
Wiring methodFront wiring (rear wiring, plug-in type optional)Front wiring (rear wiring, plug-in type optional)Consistent
Executive standardFR 14048.2, CEI 60947-2FR 14048.2, CEI 60947-2Consistent

III. Application Scenario Differences

ModèleScénarios applicablesInapplicable Scenarios
3300• Industrial/commercial power distribution trunks (requiring both overload and short-circuit protection)• Special occasions requiring only short-circuit protection
• Large motor circuits (infrequent starting)• Dedicated circuits for fire-fighting equipment (3300 model with shunt trip is usually required for fire-fighting equipment)
• General lighting and power hybrid distribution systems
3200• Used as an isolating switch (needing short-circuit protection but no overload protection)• Used alone as power distribution line protection (lack of overload protection will cause line overheating and damage)
• Occasions matched with other overload protection devices (par ex., thermal overload relays)• Direct protection for motors (unable to prevent motor burnout due to overload)
• Special short-circuit protection for specific industrial equipment
  1. Suggestions de sélection
  2. Prioritize the 3300 modèle: Most power distribution scenarios require both overload and short-circuit protection; le 3300 model provides more comprehensive protection to avoid line overheating, equipment damage and other problems caused by overload.
  3. Select the 3200 model only under specific conditions: When the system is already equipped with other overload protection devices (par ex., thermal overload relays, overload alarms), le 3200 model can be used as a dedicated short-circuit protection circuit breaker to reduce costs.
  4. Note: Le 3200 model cannot be used alone for power distribution lines requiring overload protection due to the lack of overload protection, otherwise potential safety hazards may be caused.

Précédent:

Suivant:

Laisser une réponse

Laisser un message