The Chint NXB63-3P-D63 disjoncteur is a three-phase miniature circuit breaker (MCB) designed for high-load scenarios. It is suitable for circuits with an alternating current of 50/60Hz and a rated voltage of 400V AC, providing overload, protection contre les courts-circuits, et fonctions d'isolement. Below is an analysis of its core information:
- Paramètres et fonctions de baseContacteur CA Chint NXC-75/220V
- Specification FeaturesContacteur CC Chint NC1-5011-36V
Poles: 3P. (three-phase), suitable for three-phase four-wire power distribution systems.
Courant nominal: 63UN, matching the continuous operation requirements of high-power equipment (par ex., moteurs, transformers).
Trip Characteristic: Type D curve, with an instantaneous trip current of 10–16 times the rated current, effectively handling inrush currents during motor starting.
Capacité de coupure: 6le, safely interrupting short-circuit fault currents to prevent contact welding or equipment damage.
- Technical Standards
– Complies with IEC 60898-1 (international) and GB/T 10963.1 (Chine) normes, and is 3C certified.
– Operating temperature range: -35°C to 70°C, adapting to temperature fluctuations in industrial environments.
- Scénarios d'application
Industrial Sector: Motor control, power distribution for production line equipment. The Type D trip characteristic avoids frequent false tripping.
Commercial and Residential Use: Main switches or branch protection in three-phase power supply systems, such as power distribution in shopping malls and factories.
Special Scenarios: Equipment requiring high short-circuit protection (par ex., welding machines, transformers), enabling rapid response to fault currents.
III. Installation and Usage Recommendations
- Exigences d'installation
– Must be installed by a professional electrician, vertically mounted on a standard 35mm rail, ensuring wiring screws are tightened to prevent loosening and heat generation.
– Use wires with appropriate cross-sectional area (par ex., 6mm² copper wire) and reserve sufficient operating space during wiring.
- Maintenance and Precautions
– Regularly inspect contacts and terminal blocks to avoid poor contact due to oxidation or looseness.
– Si les déclenchements se produisent fréquemment, check whether the load exceeds the rated current or if a short-circuit fault exists.
- Price and Market Positioning
Prix de référence: More cost-effective than similar imported brands (par ex., Siemens EA9 series).
Positioning: As an upgraded version of the DZ47 series, the NXB-63 improves breaking capacity and reliability, suitable for cost-sensitive scenarios requiring high protection performance.
- Comparison with Siemens Equivalent Products
Capacité de coupure: The Siemens EA9AN3C63 has a breaking capacity of 6kA, comparable to the NXB-63, but its price is typically 30–50% higher.
Trip Characteristics: Siemens Type D curve products (par ex., 5SJ6 series) have an instantaneous trip multiple of 10–14 times, close to the NXB-63’s 10–16 times, both suitable for motor protection.
Certifications: Siemens products are usually UL-certified, while the NXB-63 does not explicitly mention North American certifications. U.S. users are advised to prioritize models with UL marks.
- Précautions
Correspondance de tension: The 3P model has a rated voltage of 400V AC and cannot be used in single-phase 230V circuits.
Certification Compliance: For use in the U.S., verify whether the product is UL-certified or choose other models compliant with North American standards (par ex., Série Siemens 5SJ6).
Technical Parameters of Chint NXB63-3P-D63 Circuit Breaker
(Compiled from official data and industry standards)
- Paramètres électriques de base
- Tension nominale: C.A. 400 V (three-phase system), suitable for 380V/400V power distribution scenarios; not for single-phase 230V circuits.
- Courant nominal: 63UN, matching continuous operation of high-power equipment (par ex., moteurs, transformers).
- Trip Characteristic: Type D curve, instantaneous trip current 10–16× rated current, effectively handling motor starting inrush currents.
- Capacité de coupure: 6le (conforme à la CEI 60898-1), safely interrupting short-circuit fault currents.
- Mechanical and Environmental Parameters
- Poles: 3P. (three-phase), suitable for three-phase four-wire power distribution systems.
- Durée de vie mécanique: 20,000 opérations; Durée de vie électrique: 10,000 opérations, assurer un fonctionnement stable à long terme.
- Température de fonctionnement: -35°C à +70°C, adapting to industrial temperature fluctuations.
- Méthode d'installation: Standard 35mm rail mounting, requiring vertical fixation for heat dissipation and operational stability.
III. Certifications et conformité
- Certification nationale: 3C certified (Numéro de certificat. 2020980307001645), conforme à GB/T 10963.1.
- International Standards: Compliant with IEC 60898-1, but not explicitly UL-certified. North American users should prioritize models with UL marks (par ex., Série Siemens 5SJ6).
- Accessoires et fonctions étendues
- Contacts auxiliaires: Supports accessories like AX-X1 (1NON+1NC), MX+OF (voyage de dérivation + contact auxiliaire) for remote control and status feedback.
- Wiring Terminals: Threaded pressure plate terminals recommended for 6mm² copper wire (for 63A load), with a tightening torque of 2.0N·m to avoid heat generation.
- Dimensions and Installation Size
Dimensions: Approximately 90mm (W) × 75mm (H) × 85mm (D), subject to the official manual.
Wiring Space: Reserve sufficient space; recommended wire cross-sectional area: 1–25mm² (selected by load current).
- Notes
- Correspondance de tension: Only for 400V three-phase systems; not for single-phase 230V circuits.
- Protection contre les surcharges: Frequent tripping indicates checking whether the load exceeds the rated current or a short circuit exists.
- Marché nord-américain: Non certifié UL; recommend Siemens 5SJ6 or other North American-compliant models.
For complete technical manuals or customized parameters, visit Chint Electric’s official website or contact a supplier. For North American applications, ensure product compliance to avoid safety risks.