CHINT NXBLE-63YH-C20 is a residual current operated disjoncteur (earth leakage circuit breaker), belonging to the NXBLE series. It is mainly designed for overload, short-circuit and earth leakage protection in low-voltage distribution lines, and suitable for various scenarios such as industrial and civil applications.
Model Parameter Interpretation
| Model Segment | Description |
| SUIVANT | Product series code; NXB is the basic series of CHINT miniature circuit breakers, L indicates residual current protection (earth leakage), and E indicates high breaking capacity |
| 63 | Rated frame current is 63A. The maximum current carrying capacity of this series of circuit breakers is 63A, and C20 is the rated breaking current, which must be less than the frame current |
| YH | Special function/specification code; in this CHINT series, YH usually represents the combined function of arc fault detection device (AFDD) + residual current operated circuit breaker (RCCB/RCBO). It can detect arc faults and trip quickly, improving electrical safety |
| C20 | C-type tripping curve with a rated current of 20A; C-type tripping curve is suitable for lighting and general power loads (comme les moteurs, les fans, etc.), with an instantaneous tripping current of 5~10In (In=20A, c'est-à-dire, 100~200A) |
Paramètres techniques de base (Default Standard Configuration, Subject to Nameplate for Specific Details)
- Tension nominale: Single-phase 230V AC, three-phase 400V AC (commonly used in single-phase scenarios)
- Rated Frequency: 50Hz/60Hz
- Residual Current Operation Parameters:
Rated residual operating current (JeΔn): commonly 30mA (standard safety value for household/industrial use, which can cut off the power supply quickly to prevent electric shock); 10mA/300mA is available for customization in some models
Operating time: ≤0,1 s (instantaneous protection against short-circuit/earth leakage); the operating time of arc fault protection complies with national standard requirements
- Capacité de coupure: High breaking capacity (Class E), usually 6kA/10kA (may vary by batch, please check the nameplate), capable of withstanding high current impact during line short-circuit
- Tripping Type: C-type tripping, suitable for conventional loads to avoid non-fault tripping
- Méthode de montage: DIN rail mounting (compliant with DIN rail standard, 35mm rail, facilitating batch installation in distribution cabinets)
- Numéro de pôle: Commonly 1P+N, 2P. (please check the specific model; C20 specification is mostly 1P+N/2P, suitable for single-phase 220V lines)
Scénarios d'application
Lighting and socket circuits in civil buildings such as residences, office buildings and shopping malls, providing dual protection against electric shock and electrical fire (arc fault + earth leakage)
Small power equipment and control circuits in industrial plants, protecting equipment and the safety of operators
Places sensitive to arc faults (such as old lines and lines around flammable materials); the AFDD function can effectively reduce the risk of fire caused by arcs
Alternative Reference of Corresponding Schneider Model (Selection with the Same Function)
For brand replacement, you can refer to Schneider iDPNa Vigi+ AFDD series, such as iDPNa Vigi+ AFDD C20 30mA. The core parameters are matched: 20A rated current, C-type tripping, 30mA earth leakage protection, arc fault protection. The mounting method and breaking capacity are similar, allowing direct replacement (please check if the pole number, voltage and mounting dimensions are consistent).
Précautions d'installation et d'utilisation
- Avant l'installation, confirm that the line voltage and current match the parameters of the circuit breaker to avoid faults caused by overload or undervoltage
- Wiring must be done according to the marks on the terminals (L for live wire, N for neutral wire, PE for protective earth wire); reverse connection is strictly prohibited for 1P+N models
- Regular Testing: Press the “TEST” button of the circuit breaker once a month to check whether the earth leakage/arc protection function is normal
- Avoid use in humid, dusty and corrosive environments, which may affect the service life and operation reliability of the circuit breaker
- Cut off the upper-level power supply before replacement; live operation is strictly prohibited
Common Fault Troubleshooting
| Phénomène de défaut | Troubleshooting Direction |
| Déclenchements fréquents | 1. Load overload (par ex., starting multiple high-power devices at the same time); 2. Line leakage (insulation damage, dampness); 3. Arc fault (line aging, loose joints); 4. Circuit breaker itself failure (test button invalid, need replacement) |
| No Tripping | 1. Damaged test button; 2. Residual current protection module failure; 3. Wrong wiring (par ex., neutral wire not connected) |
Parameter Comparison Table Between CHINT NXBLE-63YH-C20 and Corresponding Schneider Model
To facilitate your direct procurement and replacement, the following is a complete parameter comparison between CHINT NXBLE-63YH-C20 (1P+N/2P) and Schneider iC65N Vigi+ C20 (1P+N model: A9D65140; 2Modèle P: A9D65240), covering core technical indicators and application compatibility.
| Catégorie de paramètre | CHINT NXBLE-63YH-C20 | Schneider iC65N Vigi+ C20 | Replacement Compatibility |
| Informations de base | |||
| Modèle de produit | NXBLE-63YH-C20 (1P+N/2P) | 1P+N: A9D65140 | Fully Compatible |
| 2P.: A9D65240 | |||
| Série de produits | NXBLE Series (upgraded replacement for DZ47LE) | Acti9 iC65 Series | Both are mainstream series for terminal power distribution |
| Type de produit | Residual current operated circuit breaker (earth leakage MCB) | Residual current operated circuit breaker (earth leakage MCB) | Consistent Function |
| Paramètres électriques de base | |||
| Numéro de pôle | 1P+N / 2P. | 1P+N / 2P. | Fully Matched |
| Courant nominal (In) | 20UN (C-curve) | 20UN (C-curve) | Completely Consistent |
| Courbe de déclenchement | C-type (instantaneous tripping 5~10 In) | C-type (instantaneous tripping 5~10 In) | Completely Consistent |
| Capacité de coupure (Icn) | 6le (YH mark indicates high breaking capacity) | 6le (N mark indicates standard breaking capacity) | Fully Matched |
| Courant de fonctionnement résiduel nominal (JeΔn) | 30mA (Type AC) | 30mA (Type A, compatible with Type AC leakage) | Functionally Compatible |
| Leakage Operating Time | ≤0,1 s (safety standard for electric shock protection) | ≤0,1 s (compliant with IEC/GB standards) | Completely Consistent |
| Rated Working Voltage | C.A. 230 V/400 V | C.A. 230 V/400 V | Completely Consistent |
| Tension d'isolation nominale | 400V | 400V | Completely Consistent |
| Physical and Installation Parameters | |||
| Méthode de montage | 35mm DIN rail mounting | 35mm DIN rail mounting | Fully Compatible |
| Méthode de câblage | Top-in bottom-out (horizontal/vertical mounting available) | Top-in bottom-out (standard DIN mounting) | Consistent Operation |
| Classe de protection | IP20 (finger protection) | IP20 (IP40 for front side, IP20 for terminals) | Suitable for distribution box application |
| Width Dimension | 1P+N: 36mm | 1P+N: 36mm | Consistent dimensions, enabling direct replacement |
| 2P.: 72mm | 2P.: 72mm | ||
| Standards and Certifications | |||
| Executive Standards | FR 10963.1, FR 13955 | CEI 60898, FR 10963.1, FR 13955 | Both comply with national standards and are applicable in China |
| Attestation | Certification CCC | CCC, Certification CE | Both meet domestic application requirements |
| Special Functions and Maintenance | |||
| Test Function | Equipped with TEST button (monthly test required) | Equipped with TEST button (monthly test required) | Consistent Operation |
| Terminal | Screw tightening, suitable for 1.5~6mm² wires | Screw tightening, suitable for 1.5~6mm² wires | Compatible with the same wire diameter |
| Température de fonctionnement | -25°C ~ +40°C | -25°C ~ +40°C | Consistent operating environment |
Key Precautions for Replacement
- Pole Number Matching: Confirm whether the original circuit is 1P+N or 2P, and select the corresponding Schneider model with the same pole number
- Leakage Type: Schneider adopts Type A earth leakage protection (compatible with Type AC), while CHINT uses Type AC. Type A has a wider application range, and replacement is risk-free
- Wiring Distinction: For 1P+N models, strictly distinguish between neutral wire (N) and live wire (L); reverse connection is prohibited
- Installation Space: The two models have the same width dimension and can directly replace the original installation position
Procurement Suggestions
For cost optimization: Choose CHINT NXBLE-63YH-C20 with higher cost performance
For brand consistency: Choose Schneider iC65N Vigi+ C20 with better compatibility with Schneider systems
For inventory replacement: The two models can be directly interchanged without modifying the circuit design or wiring method
Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires