Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

 LS ELECTRIC ABE404B-4P-400A MCCB - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

disjoncteur/

LS ELECTRIC ABE404B-4P-400A MCCB

  Model Part Meaning ABE Series code, Meta-MEC economy MCCB, thermal-magnetic trip, low breaking capacity (economy type) 40 Frame rating current 400A 4 4 poteaux (4P.), suitable for three-phase four-wire system protection B Breaking capacity class B (10kA@AC380V) 400A Rated operational current 400A, set by plug module Key Technical Parameters Item Specification Description Product Type ...

  • Détails du produit

 

Model PartSignification
ABECode de série, Meta-MEC economy MCCB, thermal-magnetic trip, low breaking capacity (economy type)
40Frame rating current 400A
44 poteaux (4P.), suitable for three-phase four-wire system protection
BBreaking capacity class B (10kA@AC380V)
400UNRated operational current 400A, set by plug module
  1. Paramètres techniques clés
ArticleSpécificationDescription
Type de produitEconomy Disjoncteur à boîtier moulé (MCCB)Déclenchement thermomagnétique, fixed mount
Tension nominaleAC 600V, Ui 690VConforme à la CEI 60947-2
Rated Frequency50/60HzUniversal frequency range
Capacité de coupureIcu=10kA@AC380VClass B economy breaking capacity
Type de voyageFixed thermal-magnetic tripProtection contre les surcharges (inverse time) + protection contre les courts-circuits (instantaneous)
Tension d'isolation nominaleUi=690VMaximum voltage for insulation performance
Mechanical Endurance8500 opérationsStandard operating cycles
Electrical Endurance1000 opérationsOperating cycles at rated current
Mounting TypeType fixeStandard 35mm DIN rail or panel mount
ConnexionConnexion frontale / Connexion arrièreOptional for different installations
Applicable StandardsCEI 60947-1/2, DANS 60947-1/2International electrical standards
  1. Series Model List (400AF Frame)
ModèlePoteauxCapacité de coupureRated Current Range
ABE402b2P.10le250UN, 300UN, 350UN, 400UN
ABE403b3P.10le250UN, 300UN, 350UN, 400UN
ABE404b4P.10le250UN, 300UN, 350UN, 400UN
ABS402b2P.25le250UN, 300UN, 350UN, 400UN
ABS403b3P.25le250UN, 300UN, 350UN, 400UN
ABS404b4P.25le250UN, 300UN, 350UN, 400UN
ABH402b2P.35le250UN, 300UN, 350UN, 400UN
ABH403b3P.35le250UN, 300UN, 350UN, 400UN
ABH404b4P.35le250UN, 300UN, 350UN, 400UN
  1. Recommended International Brand Replacements
MarqueSérieModèle de remplacementParamètres de correspondance clés
SchneiderEZD SeriesEZD400E44004P., 400UN, 10le, thermal-magnetic trip
Siemens3VT Series3VT8440-1AA034P., 400UN, 10le, thermal-magnetic trip
ABBTmax SeriesT2N400 TMD 400/400 FF 4P4P., 400UN, 10le, thermal-magnetic trip
EatonPower DefenseLZMN4-A400-I4P., 400UN, 10le, thermal-magnetic trip
Commutateur ChangshuCM3 SeriesCM3-400M/4300B 400A4P., 400UN, 10le, thermal-magnetic trip
  1. Applications & Notes de sélection
  2. Applications typiques

End protection in low-voltage distribution systems, par ex., lighting and power distribution in commercial buildings and industrial plants

Three-phase asynchronous motor protection (≤200kW, 380V)

Capacitor bank protection

Small generator outlet protection

  1. Selection Guidelines

Confirm system voltage (≤600V) and frequency (50/60Hz)

Calculate circuit rated current to ensure 400A meets long‑term operation

Evaluate short-circuit level: if >10le, use higher breaking capacity ABS (25le) or ABH (35le) série

Consider pole requirement: 4P for neutral protection applications

Confirm mounting (fixed/drawout) and connection direction (front/rear)

  1. Caractéristiques du produit & Avantages
  2. Économique & Practical: ABE series is cost-effective for budget‑limited projects
  3. Standard Design: Complies with IEC standards, interchangeable with other brands
  4. Reliable Protection: Thermal-magnetic trip provides basic overload and short-circuit protection
  5. Flexible Installation: Supports front/rear wiring and multiple mounting methods
  6. Complete Accessories: Can be equipped with auxiliary contacts, alarm contacts, déclencheur à minimum de tension, etc..
  7. Entretien & Troubleshooting
  8. Inspection régulière: Inspect appearance and tighten terminals quarterly to avoid looseness or overheating
  9. Trip Test: Perform manual trip test annually to verify mechanical reliability
  10. Troubleshooting:

Frequent overload tripping: Check load or replace with higher rated model

Short-circuit tripping: Locate and repair short circuit before closing

Failure to close: Check mechanical jam or replace damaged parts

LS ELECTRIC ABE404B-4P-400A is an economy 4-pole MCCB with 400A rated current and 10kA breaking capacity, suitable for low-voltage distribution systems with moderate breaking requirements. Pour un pouvoir de coupure plus élevé, use ABS (25le) or ABH (35le) série.

Applications of LS ELECTRIC ABE404B-4P-400A MCCB

Core Positioning:

This 4-pole economy MCCB (4P., 400UN, 10le) is mainly used for end protection in low‑voltage distribution systems, especially where neutral protection is required, short-circuit current ≤10kA, and budget is limited.

  1. Commercial Building Distribution
ApplicationSuitabilityConseil de sélection
Main distribution board main breaker4P protects 3-phase 4-wire; 400A fits small‑to‑medium commercial buildingsTotal load ≤320A (80% duty), short-circuit ≤10kA
Main A/C protection400A for large central A/C units (≤200kW, 380V)Match compressor inrush; recommend undervoltage release
Emergency lighting4P ensures neutral continuity for reliable emergency operationUse with EPS/UPS; front connection for easy maintenance
Elevator room power400A for multiple elevators; 4P prevents neutral faultsInstall in dedicated cabinet; ensure ventilation

Typical Cases:

3–5 story office buildings, chain supermarkets, hotels as main or important branch breaker.

  1. Industrial Plant Applications
  2. General Machinery

Main breaker for small‑medium production lines: 400A covers multiple branches; 10kA suits general industrial short-circuit levels

Motor group protection: Total power ≤200kW, used with thermal relays for precise protection

Auxiliary equipment: Ventilateurs, pompes, compresseurs; 4P for control circuits with neutral

  1. Specific Industries

Food processing: Cost-effective for light industry; 4P ensures safety and quality

Electronic assembly: 400A for multiple lines; 4P avoids neutral drift affecting precision equipment

Warehouse power: Main breaker for lighting and forklift charging

Warning:

If short-circuit current >10le, upgrade to LS ABS (25le) or ABH (35le).

  1. Public & Residential Buildings
  2. Education & Medical

School main distribution: 4P protects lighting, A/C, salles informatiques; 400A for whole building

Community hospital: 4P for medical equipment with neutral; economy for primary care

Stadium auxiliary systems: Éclairage, audio, seats; 400A for local zones

  1. Infrastructure

Small wastewater treatment: 400A for pumps and blowers; 4P prevents control system failure

Urban landscape lighting: Main breaker for multi-loop lighting with reliable neutral

Small waste transfer station: 400A for compressors and conveyors; low operating cost

  1. Applications spéciales
  2. Capacitor Bank Protection

For capacitor banks ≤100kvar; 4P prevents inrush and short-circuit during switching

Recommend adding SPD for surge protection

  1. Small Generator Systems

Main breaker for generators ≤300kVA; 4P ensures safe isolation from grid

Used with synchronizing equipment for smooth switch between mains and generator

  1. Temporary Power

Construction site temporary power main breaker; 400A for cranes, welders

4P suitable for harsh site conditions; prevents electric shock from broken neutral

  1. Key Selection & Application Criteria
FacteurRecommandéNot Suitable For
Short-circuit level≤10kA: suitable; >10le: use ABS/ABHHigh-risk areas (chemical, mining) avec >10le
Load typeResistive & charges inductives (éclairage, moteurs)Large rectifiers, arc furnaces, high nonlinear loads
Earthing systemTN-S, TT systems (4P neutral protection)IT systems (operating rooms, mines)
EnvironnementIndoor dry, ≤40°COutdoor, damp, explosive areas (needs special enclosure)
Operation frequencyInfrequent operation (≤12/day)Frequent duty (cranes, elevator main circuits)
  1. Application Advantages
  2. Économique: High cost-performance for budget projects
  3. Full protection: 4P design covers 3-phase + neutral for modern distribution
  4. Standard compliance: CEI 60947-2, interchangeable with major brands
  5. Flexible installation: Front/rear wiring + 35mm rail DIN
  6. Reliable: Mécanique 8500, électrique 1000 opérations

Best Combination:

Use ABE404B-4P-400A as main breaker + LS MCBs for branch protection to form a reliable two‑stage system.

For higher performance or electronic protection, upgrade to ABS (25le), ABH (35le), or ABN (electronic trip) série.