Schneider A9F18216 - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

Schneider A9F18216 - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

disjoncteur/

Schneider A9F18216

: iC65N 2P C16A Schneider A9F18216 Miniature Circuit Breaker First, it should be clarified that A9F18216 is a miniature circuit breaker (MCB) of the iC65N series, not an RCBO (Residual Current Circuit Breaker with Overcurrent protection). An RCBO is an integrated device with overload, short-circuit and earth leakage protection, while A9F18216 only provides overload and ...

  • Détails du produit

: iC65N 2P C16A Schneider A9F18216 Miniature Circuit Breaker

D'abord, it should be clarified that A9F18216 is a disjoncteur miniature (MCB) of the iC65N series, not an RCBO (Residual Current Circuit Breaker with Overcurrent protection). An RCBO is an integrated device with overload, short-circuit and earth leakage protection, while A9F18216 only provides overload and short-circuit protection. For earth leakage protection, it must be used with an additional Vigi iC60 or QuickVigi iC60 residual current module.

Model Code Breakdown

Model PartSignification
iC65NSérie de produits: Acti9 iC65 series; N stands for 6kA breaking capacity
2P.Nombre de pôles: 2 poteaux (Line + Neutre)
CCourbe de déclenchement: Tapez C, for power distribution and lighting circuits; instantaneous tripping at 5–10× rated current
16UNCourant nominal: 16 ampères
A9F18216Schneider official order code

Core Technical Specifications

ArticleDetailed Specification
Type de produitDisjoncteur miniature (MCB)
SérieActi9 iC65N
Nombre de pôles2P. (2-wire system, 2 protected poles)
Courant nominal (Dans)16UN
Courbe de déclenchementTapez C
Capacité de coupure (ICU)6le (400V et)
Tension nominale230/400V et
Fréquence50/60Hz
Dimensions2 modules (36mm largeur)
MontageMontage sur rail DIN
Degree of ProtectionIP20
Tripping TypeThermique-magnétique (surcharge: bimetal strip; court-circuit: magnetic coil)
Normes applicablesCEI 60898-1

Caractéristiques du produit & Fonctions

  1. Reliable Protection: Provides overload and short-circuit protection to prevent electrical fires and equipment damage
  2. Courbe de type C: Suitable for power distribution, lighting circuits and resistive loads, with good inrush current tolerance
  3. Conception compacte: 2-module width, saving space in distribution boards
  4. VisiTrip Indicator: Red mechanical window shows trip status for quick fault diagnosis
  5. Multiple Wiring Methods: Supports front, rear and rail-mounted wiring to meet various installation needs
  6. Wide Operating Temperature Range: -25°C à +40°C, adaptable to various environments

Difference from RCBO and Earth Leakage Protection Solutions

Type de produitFonctions de protectionModèle typiqueInstallation
A9F18216 (iC65N 2P C16A)Surcharge + Court-circuitA9F18216Standalone
RCBO (iC65N Vigi+)Surcharge + Court-circuit + Earth LeakageA9D11216 (2P C16A 30mA Type A)Integrated
MCB + Leakage ModuleSurcharge + Court-circuit + Earth LeakageA9F18216 + A9Q41216 / A9V41216Module attached to right of MCB

To upgrade A9F18216 to a system with earth leakage protection, you may choose:

QuickVigi iC60 2P 16A 30mA module (A9Q41216, 1.5 modules, space-saving)

Vigi iC60 2P 16A 30mA module (A9V41216, 3 modules, version standard)

Applications

Suitable for overload and short-circuit protection in final distribution systems, especially for:

Lighting circuits in residential and commercial buildings

Circuits for small power equipment and resistive loads

Branch protection in distribution boards

Applications requiring flexible combination with earth leakage modules

Key Installation & Operating Instructions

  1. Monté sur rail DIN standard de 35 mm
  2. Plage de température de fonctionnement: -25°C à +40°C
  3. Degré de pollution: 3
  4. Rated impulse withstand voltage (Ump): 6kV
  5. Capacité de câblage: maximum. 25mm² cable
  6. Endurance mécanique: 20,000 operating cycles

A9F18216 is a commonly used 2P 16A Type C MCB from Schneider’s Acti9 series, offering reliable overload and short-circuit protection. If earth leakage protection is required, a corresponding residual current module must be added, or an RCBO from the iC65N Vigi+ series (par ex., A9D11216) can be selected directly.

Supplementary Information for Schneider A9F18216: Official Ordering, Full Series List & Chinese Domestic Alternatives

  1. Official Ordering Information
ArticleDétails
Product NameiC65N 2P C16A Miniature Circuit Breaker (MCB)
Official Order CodeA9F18216
SérieActi9 iC65N (N = 6kA breaking capacity)
Courant de trame63UN
Tension nominale230/400V et
Fréquence50/60Hz
Capacité de coupure (ICU)6le (400V et)
Courbe de déclenchementTapez C (instantaneous trip at 5–10× In)
Nombre de pôles2P. (2-wire, Line + Neutre)
Courant nominal16UN
Dimensions2 modules (36mm largeur)
MontageMontage sur rail DIN
Degree of ProtectionIP20
Normes applicablesCEI 60898-1, FR 14048.2
Capacité de câblageMax. 25mm² cable
Mechanical Endurance20,000 operating cycles
Période de garantie12 mois
  1. Full Model List of iC65N Series (A9F Prefix)

The iC65N series is categorized by pole number. Order code rule: A9F + [Pole Code] + [Current Code]

Pole codes: 11=1P, 12=2P, 13=3P, 14=4P

Current codes: 06=6A, 08=8A, 10=10A, 13=13A, 16=16A, 20=20A, 25=25A, 32=32A, 40=40A, 50=50A, 63=63A

1P Models (A9F181xx)

Courant nominalCode de commandeCourbe de déclenchement
6UNA9F18106Tapez C
8UNA9F18108Tapez C
10UNA9F18110Tapez C
13UNA9F18113Tapez C
16UNA9F18116Tapez C
20UNA9F18120Tapez C
25UNA9F18125Tapez C
32UNA9F18132Tapez C
40UNA9F18140Tapez C
50UNA9F18150Tapez C
63UNA9F18163Tapez C

2P Models (A9F182xx)

Courant nominalCode de commandeCourbe de déclenchement
6UNA9F18206Tapez C
8UNA9F18208Tapez C
10UNA9F18210Tapez C
13UNA9F18213Tapez C
16UNA9F18216Tapez C
20UNA9F18220Tapez C
25UNA9F18225Tapez C
32UNA9F18232Tapez C
40UNA9F18240Tapez C
50UNA9F18250Tapez C
63UNA9F18263Tapez C

3P Models (A9F183xx)

Courant nominalCode de commandeCourbe de déclenchement
6UNA9F18306Tapez C
8UNA9F18308Tapez C
10UNA9F18310Tapez C
13UNA9F18313Tapez C
16UNA9F18316Tapez C
20UNA9F18320Tapez C
25UNA9F18325Tapez C
32UNA9F18332Tapez C
40UNA9F18340Tapez C
50UNA9F18350Tapez C
63UNA9F18363Tapez C

4P Models (A9F184xx)

Courant nominalCode de commandeCourbe de déclenchement
6UNA9F18406Tapez C
8UNA9F18408Tapez C
10UNA9F18410Tapez C
13UNA9F18413Tapez C
16UNA9F18416Tapez C
20UNA9F18420Tapez C
25UNA9F18425Tapez C
32UNA9F18432Tapez C
40UNA9F18440Tapez C
50UNA9F18450Tapez C
63UNA9F18463Tapez C

Modèles spéciaux (Tapez D / Capacité de coupure élevée)

ModèleDescriptionCode de commande
iC65N 2P D16AType D curve (10–14×In), for motor loadsA9F18216D
iC65H 2P C16AHigh breaking capacity 10kAA9F18216H
iC65L 2P C16ALow breaking capacity 4.5kAA9F18216L
  1. Chinese Domestic Brand Alternatives (2P C16A MCB)
MarqueSérieModèleCapacité de coupurePrincipales fonctionnalitésRéférence de prix
CHINTNXB-63NXB-63 2P C16A6leLeading domestic brand, rentable, Certifié CCC40–50% of Schneider
DÉLIXIDZ47sDZ47s 2P C16A6leWell-known domestic brand, reliable quality, widely used40–50% of Schneider
NAXINNDM1NDM1-63 2P C16A6leIndustrial-grade quality, suitable for engineering projects50–60% of Schneider
Commutateur ChangshuCH1CH1-63 2P C16A6leEstablished state-owned enterprise, mature technology50–60% of Schneider
People ElectricRMK-63RMK-63 2P C16A6leAffordable price, suitable for bulk purchase30–40% of Schneider

Key Selection Guidelines for Alternatives

  1. Matching breaking capacity: Ensure alternative ≥6kA, same as iC65N
  2. Matching tripping curve: Type C for power/lighting; Type D for motors
  3. Dimension compatibility: All 2 modules (36mm), DIN rail mount, fits distribution boards
  4. Complete certification: Must have CCC; CE recommended for industrial use
  5. Capacité de câblage: Ensure max. wiring ≥25mm² to meet site requirements
  6. Earth Leakage Protection Upgrade Solutions

Two options to upgrade A9F18216 with earth leakage protection:

Option 1: MCB + Leakage Module Combination

Module TypeModèleSpécificationLargeurCode de commande
QuickVigi iC602P 16A 30mA ACCompact 1.5 modules27mmA9Q41216
Vigi iC602P 16A 30mA ACStandard 3 modules63mmA9V41216
Vigi iC602P 16A 30mA ADetects pulsating DC leakage63mmA9V42216

Option 2: Direct Replacement with RCBO

Schneider RCBO ModelDescriptionCode de commande
iC65N Vigi+ 2P C16A 30mA AIntegrated leakage protectionA9D11216
iC65N Vigi+ 2P C16A 30mA ACIntegrated leakage protectionA9D10216

A9F18216 is the standard 2P C16A model in the Schneider iC65N series with clear ordering information. The series covers various pole numbers and current ratings. Abundant Chinese domestic alternatives are available for flexible selection based on project budget and quality requirements. Earth leakage protection can be achieved by adding a leakage module or replacing with an RCBO to ensure safe and reliable electrical systems.

Full Model List of Schneider A9F18216 in the Same Series (iC65N Series)

  1. Model Coding Rule Explanation

The coding rule for A9F-prefixed order codes of Schneider iC65N series MCBs is as follows:

Code PartSignification
A9FProduct category: Acti9 iC65 MCB
17Type B curve (instantaneous trip at 2–5×In)
18Type C curve (instantaneous trip at 5–10×In, standard for lighting & distribution)
19Type D curve (instantaneous trip at 10–14×In, for motor loads)
1/2/3/4Nombre de pôles: 1=1P, 2=2P, 3=3P, 4=4P
01/02/04/06…63Courant nominal: 1UN, 2UN, 4UN, 6UN…63UN
  1. Full Model List (By Pole Number)

2.1 1P Models (A9F[17/18/19]1xx)

Courant nominalTapez B (A9F171xx)Tapez C (A9F181xx)Tapez D (A9F191xx)
1UNA9F17101A9F18101A9F19101
2UNA9F17102A9F18102A9F19102
4UNA9F17104A9F18104A9F19104
6UNA9F17106A9F18106A9F19106
8UNA9F17108A9F18108A9F19108
10UNA9F17110A9F18110A9F19110
13UNA9F17113A9F18113A9F19113
16UNA9F17116A9F18116A9F19116
20UNA9F17120A9F18120A9F19120
25UNA9F17125A9F18125A9F19125
32UNA9F17132A9F18132A9F19132
40UNA9F17140A9F18140A9F19140
50UNA9F17150A9F18150A9F19150
63UNA9F17163A9F18163A9F19163

2.2 2P Models (A9F[17/18/19]2xx)

Courant nominalTapez B (A9F172xx)Tapez C (A9F182xx)Tapez D (A9F192xx)
1UNA9F17201A9F18201A9F19201
2UNA9F17202A9F18202A9F19202
4UNA9F17204A9F18204A9F19204
6UNA9F17206A9F18206A9F19206
8UNA9F17208A9F18208A9F19208
10UNA9F17210A9F18210A9F19210
13UNA9F17213A9F18213A9F19213
16UNA9F17216A9F18216A9F19216
20UNA9F17220A9F18220A9F19220
25UNA9F17225A9F18225A9F19225
32UNA9F17232A9F18232A9F19232
40UNA9F17240A9F18240A9F19240
50UNA9F17250A9F18250A9F19250
63UNA9F17263A9F18263A9F19263

2.3 3P Models (A9F[17/18/19]3xx)

Courant nominalTapez B (A9F173xx)Tapez C (A9F183xx)Tapez D (A9F193xx)
1UNA9F17301A9F18301A9F19301
2UNA9F17302A9F18302A9F19302
4UNA9F17304A9F18304A9F19304
6UNA9F17306A9F18306A9F19306
8UNA9F17308A9F18308A9F19308
10UNA9F17310A9F18310A9F19310
13UNA9F17313A9F18313A9F19313
16UNA9F17316A9F18316A9F19316
20UNA9F17320A9F18320A9F19320
25UNA9F17325A9F18325A9F19325
32UNA9F17332A9F18332A9F19332
40UNA9F17340A9F18340A9F19340
50UNA9F17350A9F18350A9F19350
63UNA9F17363A9F18363A9F19363

2.4 4P Models (A9F[17/18/19]4xx)

Courant nominalTapez B (A9F174xx)Tapez C (A9F184xx)Tapez D (A9F194xx)
1UNA9F17401A9F18401A9F19401
2UNA9F17402A9F18402A9F19402
4UNA9F17404A9F18404A9F19404
6UNA9F17406A9F18406A9F19406
8UNA9F17408A9F18408A9F19408
10UNA9F17410A9F18410A9F19410
13UNA9F17413A9F18413A9F19413
16UNA9F17416A9F18416A9F19416
20UNA9F17420A9F18420A9F19420
25UNA9F17425A9F18425A9F19425
32UNA9F17432A9F18432A9F19432
40UNA9F17440A9F18440A9F19440
50UNA9F17450A9F18450A9F19450
63UNA9F17463A9F18463A9F19463
  1. Special Versions (Capacité de coupure / Extension des fonctions)
ModèleDescriptionCode de commandeRemarques
iC65H 2P C16AHigh breaking capacity 10kAA9F18216HH = High breaking
iC65L 2P C16ALow breaking capacity 4.5kAA9F18216LL = Low breaking
iC65N 2P C16A RWith overload alarm contactA9F18216RR = With alarm contact
iC65N 2P C16A DCFor DC circuits onlyA9F18216DCFor DC system protection
  1. Unified Key Technical Specifications

All A9F-prefixed iC65N models share the following core parameters:

Pouvoir de coupure (ICU): 6le (400V et)

Tension nominale: 230/400V et

Fréquence: 50/60Hz

Dimensions: 1P=1 module (18mm), 2P=2 modules (36mm), 3P=3 modules (54mm), 4P=4 modules (72mm)

Montage: Montage sur rail DIN

Degree of Protection: IP20

Tripping type: Thermique-magnétique (surcharge: bimetal strip; court-circuit: magnetic coil)

Normes applicables: CEI 60898-1, FR 14048.2

  1. Guide de sélection
  2. Tripping Curve Selection

Tapez B: For pure resistive loads (par ex., lampes à incandescence)

Tapez C: For general power and lighting loads (most commonly used)

Tapez D: For inductive loads such as motors and transformers

  1. Sélection du numéro de pôle

1P.: Protects line only, for single-phase lighting circuits

2P.: Protects line + neutre, for single-phase socket circuits

3P.: Protects three phases, for three-phase power circuits

4P.: Protects three phases + neutre, for three-phase four-wire systems

  1. Breaking Capacity Selection

Tapez N (6le): For general residential and commercial buildings

Tapez H (10le): For industrial sites or distribution systems near transformers

Type L (4.5le): For simple lighting systems

Précédent:

Laisser une réponse

Laisser un message