SchneiderC10F32D100: Disjoncteur à boîtier moulé ComPacT NSX100F - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

disjoncteur/

SchneiderC10F32D100: Disjoncteur à boîtier moulé ComPacT NSX100F

Model Interpretation C10F32D100 is the complete order code of Schneider’s new-generation ComPacT NSX series molded case circuit breakers. The meaning of each segment is as follows: Code Segment Meaning Description C10 Frame Size and Breaking Capacity C10 = NSX100F, frame current 100A, breaking capacity Class F (36kA@415VAC) F Breaking Capacity Class F = 36kA@415VAC, suitable ...

  • Détails du produit
  1. Model Interpretation

C10F32D100 is the complete order code of Schneider’s new-generation ComPacT NSX series disjoncteurs à boîtier moulé. The meaning of each segment is as follows:

Code SegmentSignificationDescription
C10Frame Size and Breaking CapacityC10 = NSX100F, frame current 100A, breaking capacity Class F (36kA@415VAC)
FBreaking Capacity ClassF = 36kA@415VAC, suitable for standard industrial applications
3Number of Poles3 = 3-pole (3P3D, three-phase three-wire system)
2DTrip Unit Type2D = MicroLogic 2.2 electronic trip unit with display function
100Courant nominal100UN, adjustable range 90-100A
  1. Paramètres techniques de base

Paramètres de base

ParamètreValeurDescription
Type de produitMolded Case Circuit Breaker (MCCB)New-generation ComPacT NSX100F
Tension nominale690VAC/50-60HzMaximum operating voltage
Courant nominal (Iu)100UNContinuous operating current
Ultimate Breaking Capacity (ICU)36kA@415VACUltimate breaking capacity
Service Breaking Capacity (Ics)36kA@415VAC (100%)Service breaking capacity
Mounting TypeFixéStandard mounting, plug-in type optional (C10F32D100P)
Protection CategoryCategory AComplies with IEC 60947-2 standard

MicroLogic 2.2 Trip Unit Parameters

Fonction de protectionCharacteristicAdjustable Range
Long-time Delay Protection (L)Protection contre les surcharges, inverse time-lag0.8-1.0脳Iu (90-100UN)
Short-time Delay Protection (S)Protection contre les courts-circuits, definite time-lag3-6脳Iu, réglable
Instantaneous Protection (je)Short-circuit instantaneous tripping, fixed10脳Iu (1000UN)
Display FunctionCurrent measurement and status indicationReal-time display of three-phase current

Physical and Electrical Characteristics

ParamètreValeur
Power Loss14.1W
PoidsApproximately 2.5kg
Compliance StandardsCEI 60947-2, FR 14048.2
CertificationsCE, CCC, RoHS

III. Caractéristiques fonctionnelles

  1. Comprehensive Protection: Provides three-stage protection including long-time delay, short-time delay and instantaneous protection, effectively preventing overload and short-circuit faults.
  2. Precise Control: Compared with thermal-magnetic trip units (TM series), electronic trip units offer more accurate protection curves and adjustable parameters.
  3. Status Visualization: MicroLogic 2.2 is equipped with LED display for real-time monitoring of current and fault status.
  4. Conception modulaire: Supports a variety of accessories (contacts auxiliaires, alarm contacts, déclencheur à minimum de tension, etc.) for flexible installation.
  5. Environmental Friendly: Schneider Green Signature design, reducing energy consumption and carbon footprint.
  6. Easy Operation: Ergonomic handle for labor-saving operation; front-mounted accessories reduce wiring time by 40%.
  7. Scénarios d'application
  8. Industrial Power Distribution Systems: Used as main switch or branch switch to protect motors, transformers and distribution lines.
  9. Building Electrical Systems: Low-voltage distribution cabinets in commercial buildings and industrial plants.
  10. Motor Control Centers (MCC): Protect three-phase motors from locked rotor and overload conditions.
  11. Data Centers: Power protection for critical loads to ensure power supply continuity.
  12. New Energy Sector: DC-side protection of photovoltaic inverters and energy storage systems (additional configuration required).
  13. Product Comparison

Comparison with Trip Units of the Same Series

ModèleTrip Unit TypeMain DifferencesScénarios d'application
C10F32D100MicroLogic 2.2Electronic trip unit with display, three-stage protectionIndustrial applications requiring precise protection and monitoring
C10F3TM100TM100D Thermal-Magnetic TripThermal-magnetic trip unit, two-stage protection, rentableSimple power distribution without precise adjustment requirements
C10F33D100MicroLogic 3.2Added earth fault protection (30-3000mA)

Comparison with Chint Alternative Models

Schneider ModelChint Alternative ModelSimilaritiesDifferences
C10F32D100NM1-125S/3300 100A3-pôle, 100UN, 36kA breaking capacityChint adopts thermal-magnetic trip unit without display; Schneider adopts electronic trip unit with display
NM1-125H/3340 100A3-pôle, 100UN, electronic trip unitChint has 50kA breaking capacity with slightly different protection functions
  1. Selection and Usage Recommendations
  2. Points clés de la sélection

Select protection curves according to load types: for motor loads, it is recommended to set short-time delay to 5-6×Iu

Breaking capacity should be greater than the expected short-circuit current of the system

Consider future expansion; rated current should be slightly higher than the actual load current

  1. Précautions d'installation

Ensure the mounting surface is flat and the tightening torque meets requirements (screw torque 25N·m)

Corresponding cable lugs must be used for terminal connections to avoid heating caused by poor contact

Leave sufficient heat dissipation space around and avoid close installation with heat-generating components

  1. Recommandations d'entretien

Regular inspection (at least once a year): appearance, tightness status, flexibility of operating mechanism

Check contact condition after short-circuit tripping and replace if necessary

Clean with dry compressed air to avoid moisture and dust accumulation

VII. Troubleshooting Guide

Phénomène de défautCauses possiblesTroubleshooting Steps
Failure to Close1. Undervoltage release without power supply

2. Trip unit malfunction

3. Mechanical lockout

1. Check control power supply (if equipped)

2. Measure trip unit coil resistance

3. Manually reset the trip mechanism

False Tripping1. Surcharge

2. Short circuit

3. Improper trip unit parameter setting

1. Check load current

2. Check line insulation

3. Reset trip unit parameters

No Display After Tripping1. Trip unit power supply failure

2. Trip unit damage

1. Check trip unit power supply

2. Replace the trip unit