ParamètreValeurDescription
Numéro de pôle2P.Two-pole design, protecting both the positive and negative poles of the circuit simultaneously
Courant nominal6UNMaximum current for normal operation
Tripping CharacteristicTapez CStandard tripping curve with an instantaneous tripping range of 8.5In 20%
Tension nominale125V DCSuitable for 125V DC systems
Capacité de coupure6leMaximum short-circuit current that can be safely interrupted at 125V DC
Méthode de montageDIN Rail MountingStandard 35mm rail mounting
Product ModelA9N22423Schneider internal part number

  • Détails du produit

C65N-DC/2P-C6A is a disjoncteur miniature specifically designed for DC systems by Schneider Electric (Acti9 series). The detailed parameters are as follows:

ParamètreValeurDescription
Numéro de pôle2P.Two-pole design, protecting both the positive and negative poles of the circuit simultaneously
Courant nominal6UNMaximum current for normal operation
Tripping CharacteristicTapez CStandard tripping curve with an instantaneous tripping range of 8.5In 20%
Tension nominale125V DCSuitable for 125V DC systems
Capacité de coupure6leMaximum short-circuit current that can be safely interrupted at 125V DC
Méthode de montageDIN Rail MountingStandard 35mm rail mounting
Product ModelA9N22423Schneider internal part number

Working Principle & Caractéristiques

The C65N-DC series is a circuit breaker dedicated to DC systems, featuring the following characteristics:

  1. Arc Extinguishing System: Equipped with a special arc extinguishing device designed specifically for DC circuits, effectively quenching DC arcs (DC arcs are more difficult to extinguish than AC arcs).
  2. Tripping Characteristics:

Type C Curve: Suitable for protection of general loads and distribution lines, with an instantaneous tripping current of approximately 51A (8.5×6A).

Thermal-Magnetic Tripping: Integrates dual protection functions of overload protection (thermal protection) et protection contre les courts-circuits (magnetic protection).

  1. Structural Features:

Compact design with a depth of only 68mm, saving installation space.

Mechanical service life of up to 20,000 opérations, ensuring high reliability.

Protection class IP20 (for the unit itself) / IP40 (when installed in distribution boxes), providing dust and electric shock protection.

Scénarios d'application

This circuit breaker is suitable for various DC power supply systems:

Industrial Automation: DC motor control, PLC control systems.

New Energy Sector: Solar inverter output protection, systèmes de stockage d'énergie.

Communication Equipment: DC-powered devices such as base stations and switches.

Rail Transit: Vehicle auxiliary power supply systems.

Marine Electrical Systems: DC distribution systems.

Typical Application: Protecting DC loads below 6A, such as sensors, small controllers, module de communication, etc..

Selection & Usage Notes

  1. Voltage Matching: Must be used with 125V DC systems; not applicable for AC systems.
  2. Current Selection:

The rated current (6UN) should be greater than the maximum operating current of the circuit.

Consider load starting current: Type C curve allows short-term overloads (par ex., motor startup).

  1. Pole Number Selection: The 2P structure disconnects both positive and negative poles simultaneously, providing safer circuit isolation.

C65N-DC/2P-C6A is a compact protection device developed by Schneider for DC systems. Integrating overload protection, protection contre les courts-circuits, and circuit control functions, it is particularly suitable for protecting loads below 6A in 125V DC systems.