disjoncteur/

Schneider EA9AN2C25 Miniature Circuit Breaker

2 poteaux, Courbe de déclenchement de type C, 25Un courant nominal, 6kA pouvoir de coupure, 230/400V AC rated voltage. Suitable for overload and short-circuit protection in residential, commercial and light industrial power distribution systems. Model Breakdown EA9AN2C25 = EA9AN (series code) + 2 (number of poles: 2P.) + C (courbe de déclenchement) + 25 (courant nominal: 25UN) EA9AN: Standard ...

  • Détails du produit

2 poteaux, Courbe de déclenchement de type C, 25Un courant nominal, 6kA pouvoir de coupure, 230/400V AC rated voltage. Suitable for overload and short-circuit protection in residential, commercial and light industrial power distribution systems.

  1. Model Breakdown

EA9AN2C25 = EA9AN (series code) + 2 (number of poles: 2P.) + C (courbe de déclenchement) + 25 (courant nominal: 25UN)

EA9AN: Standard disjoncteur miniature from Schneider Easy9 series, slim design at 18mm per pole, high space utilization in distribution boards.

2P.: 2-pole protection, disconnects both live and neutral wires for enhanced electrical safety.

C: Type C tripping characteristic, tripping range 5–10×In, suitable for general loads such as lighting and sockets.

25: Rated current 25A, stable operation at 30℃ ambient temperature.

  1. Key Technical Specifications
ArticleSpécification
Tension de fonctionnement nominale (Ue)230/400V CA 50 Hz
Tension d'isolation nominale (Interface utilisateur)500V et
Tension de tenue aux impulsions nominale (Ump)4kV
Rated Breaking Capacity (Icn)6000UN (400V et)
Caractéristique de déclenchementTapez C (5–10In)
Courant nominal (Dans)25UN (at 30℃)
Electrical Endurance10,000 operating cycles
Mechanical Endurance20,000 operating cycles
MontageMontage sur rail DIN (width 2×9mm = 18mm)
ConnexionScrew clamp terminals
Température ambiante-30℃ to +70℃
StandardsGB10963 / CEI 60898-1
  1. Caractéristiques du produit & Avantages
  2. Safe & Reliable: Excellent current-limiting performance reduces fault impact on systems and equipment, improving safety and electrical life.
  3. Opération facile: Fast make-and-break design minimizes arcing on contacts; intuitive operation, clear fault indication, and simple installation without complex commissioning.
  4. Rentable: High performance-to-price ratio for residential, retail and small office applications; full series compliant with national standards, flame-retardant and eco-friendly enclosure.
  5. Conception modulaire: Can be assembled with Easy9 series surge protective devices, over/undervoltage accessories and other modules for expanded protection functions.
  6. Applications

Residential distribution systems: Protection for lighting and socket circuits in living rooms, chambres à coucher, etc..

Commercial buildings: Installation in distribution boards of small shops and offices.

Light industrial equipment: Auxiliary circuit protection in control cabinets.

Public facilities: Overload and short-circuit protection for lighting systems and small power equipment.

  1. Sélection & Replacement Recommendations
  2. Application Matching

Suitable for load circuits with total power ≤5.5kW (230V) or ≤17kW (380V).

Recommended for resistive loads (par exemple. éclairage) and general inductive loads (par exemple. climatiseurs, refrigerators and other household appliances).

  1. Modèles alternatifs

Upgraded within the same series: EA9AH2C25 (10kA pouvoir de coupure, for higher short-circuit risk environments).

Same-brand alternative: Acti9 series C65N2C25 (performances similaires, compatible dimensions).

Domestic brand alternatives: CHINT NXB-63 2P C25, DELIXI DZ47s 2P C25 (lower cost, comparable performance).

  1. Installation & Notes d'utilisation
  2. Avant l'installation, verify the model matches load requirements and check rated current and number of poles.
  3. Installer au sec, ventilated environments, away from high temperatures, humidity and corrosive conditions.
  4. Ensure conductors meet specifications during wiring, with proper torque to avoid overheating from loose connections.
  5. Inspect the breaker regularly to ensure flexible operation, no damage or overheating.
  6. After a fault trip, identify and resolve the cause before resetting; avoid repeated closing without troubleshooting.

Schneider Easy9 (EA9) Series Model List & Order Numbers

Schneider EA9 (Easy9) series is a product line of miniature circuit breakers and protective devices for residential, commercial and light industrial power distribution, featuring slim design (18mm/pole), cost efficiency and easy installation. Below is the complete model format, specification range and ordering rules by sub-series.

  1. EA9 Series Naming Convention

EA9XXX[Poteaux][Curve][Current][Suffixe]

ComposantDescriptionOptions
EA9Series identifier (Easy9)Fixé
XXXSub-series codeAN (standard, 6le), AH (rupture élevée, 10le), R. (RCBO), B/L (SPD), etc..
PoteauxNombre de pôles1 (1P.), 2 (2P.), 3 (3P.), 4 (4P.), 1+N (1P+N)
CurveTripping characteristicC (5–10In, general loads), D (10–14In, power loads), B (3–5In, sensitive electronics)
CurrentCourant nominal6UN,10UN,16UN,20UN,25UN,32UN,40UN,50UN,63UN (AN); 63UN,80UN,100UN,125UN (AH)
SuffixeSpecial markingNEW (new version), R. (with indicator), 30C (30mA Type A earth leakage), etc..
  1. EA9AN Series (Standard MCB, 6kA Breaking Capacity)

2.1 Complete Model List

PoteauxCurveCourant nominalModèle (Numéro de commande)
1P.C6A/10A/16A/20A/25A

/32A/40A/50A/63A

EA9AN1C06, EA9AN1C10, EA9AN1C16, EA9AN1C20, EA9AN1C25, EA9AN1C32, EA9AN1C40, EA9AN1C50, EA9AN1C63
D10A/16A/20A/25A

/32A/40A/50A/63A

EA9AN1D10, EA9AN1D16, EA9AN1D20, EA9AN1D25, EA9AN1D32, EA9AN1D40, EA9AN1D50, EA9AN1D63
2P.C6A/10A/16A/20A

/25A/32A/40A/50A/63A

EA9AN2C06, EA9AN2C10, EA9AN2C16, EA9AN2C20, EA9AN2C25, EA9AN2C32, EA9AN2C40, EA9AN2C50, EA9AN2C63
D10A/16A/20A/25A

/32A/40A/50A/63A

EA9AN2D10, EA9AN2D16, EA9AN2D20, EA9AN2D25, EA9AN2D32, EA9AN2D40, EA9AN2D50, EA9AN2D63
3P.C6A/10A/16A/20A

/25A/32A/40A/50A/63A

EA9AN3C06, EA9AN3C10, EA9AN3C16, EA9AN3C20, EA9AN3C25, EA9AN3C32, EA9AN3C40, EA9AN3C50, EA9AN3C63
D10A/16A/20A/25A/

32A/40A/50A/63A

EA9AN3D10, EA9AN3D16, EA9AN3D20, EA9AN3D25, EA9AN3D32, EA9AN3D40, EA9AN3D50, EA9AN3D63
4P.C6A/10A/16A/20A/

25A/32A/40A/50A/63A

EA9AN4C06, EA9AN4C10, EA9AN4C16, EA9AN4C20, EA9AN4C25, EA9AN4C32, EA9AN4C40, EA9AN4C50, EA9AN4C63
D10A/16A/20A/25A

/32A/40A/50A/63A

EA9AN4D10, EA9AN4D16, EA9AN4D20, EA9AN4D25, EA9AN4D32, EA9AN4D40, EA9AN4D50, EA9AN4D63

2.2 Order Number Notes

Standard models use the same code for model and order number, par exemple. order number for EA9AN2C25 is EA9AN2C25.

Models with indicator: add suffix “R”, par exemple. EA9AN3C40R.

Packing: 4 pièces/boîte, 32 pcs/carton (standard).

  1. EA9AH Series (High Breaking MCB, 10kA Breaking Capacity)

3.1 Complete Model List

PoteauxCurveCourant nominalModèle (Numéro de commande)
2P.C63A/80A/100A/125AEA9AH2C63NEW, EA9AH2C80NEW, EA9AH2C100NEW, EA9AH2C125NEW
D63A/80A/100A/125AEA9AH2D63NEW, EA9AH2D80NEW, EA9AH2D100NEW, EA9AH2D125NEW
3P.C63A/80A/100A/125AEA9AH3C63NEW, EA9AH3C80NEW, EA9AH3C100NEW, EA9AH3C125NEW
D63A/80A/100A/125AEA9AH3D63NEW, EA9AH3D80NEW, EA9AH3D100NEW, EA9AH3D125NEW
4P.C63A/80A/100A/125AEA9AH4C63NEW, EA9AH4C80NEW, EA9AH4C100NEW, EA9AH4C125NEW
D63A/80A/100A/125AEA9AH4D63NEW, EA9AH4D80NEW, EA9AH4D100NEW, EA9AH4D125NEW

3.2 Order Number Notes

New models carry the “NEW” suffix, par exemple. EA9AH4D100NEW.

Packing: 3 pièces/boîte, 18 pcs/carton.

  1. EA9R Series (Disjoncteur à courant résiduel, RCBO)

4.1 Complete Model List (1P+N / 2P. / 3P. / 4P.)

PoteauxCurveCourant nominalEarth LeakageModèle (Numéro de commande)
1P+NC16A/20A/25A/32A

/40A/50A/63A

30mA Type AEA9RN1C1630CAR, EA9RN1C2030CAR, EA9RN1C2530CAR, EA9RN1C3230CAR, EA9RN1C4030CAR, EA9RN1C5030CAR, EA9RN1C6330CAR
2P.C16A/20A/25A/32

A/40A/50A/63A

30mA Type AEA9RN2C1630C, EA9RN2C2030C, EA9RN2C2530C, EA9RN2C3230C, EA9RN2C4030C, EA9RN2C5030C, EA9RN2C6330C
3P.C16A/20A/25A/32A

/40A/50A/63A

30mA Type AEA9RN3C1630C, EA9RN3C2030C, EA9RN3C2530C, EA9RN3C3230C, EA9RN3C4030C, EA9RN3C5030C, EA9RN3C6330C
4P.C16A/20A/25A/32A

/40A/50A/63A

30mA Type AEA9RN4C1630C, EA9RN4C2030C, EA9RN4C2530C, EA9RN4C3230C, EA9RN4C4030C, EA9RN4C5030C, EA9RN4C6330C

4.2 Order Number Notes

RCBO model format: EA9RN[Poteaux][Curve][Current][Leakage][Taper]

Leakage rating: 30C = 30mA Type A (standard); 30CAR = 30mA Type A with indicator.

Packing: 20 pcs/carton (standard).

  1. Overview of Other EA9 Sub-Series
Sub-SeriesType de produitPrincipales fonctionnalitésModèle typique
EA9B/EA9LDispositif de protection contre les surtensions (SPD)Lightning & surge protection, for main/end distributionEA9B208, EA9L208 (2P 8kA)
EA9CModular ContactorFor control circuits, 2NO/2NC contactsEA9C20116 (2P 16A 2NO 220V)
EA9 AccessoriesOver/Undervoltage / Déclenchement de dérivationAssembled with EA9 breakersEA9XU2 (2P over/undervoltage accessory)
  1. Sélection & Replacement Advice
  2. EA9AN vs EA9AH

EA9AN (6le): For standard residential and commercial distribution.

EA9AH (10le): For industrial environments and high short-circuit risk locations.

  1. Replacement Options

Same-brand upgrade: Acti9 series C65N2C25 (performances similaires, dimensionally compatible).

Domestic alternatives: CHINT NXB-63 2P C25, DELIXI DZ47s 2P C25 (lower cost).

  1. Ordering Tips

New models (par exemple. EA9AH series) are marked with “NEW”; old versions are being phased out.

Confirm number of poles, tripping curve and rated current before ordering to avoid mismatches.

Translation Notes

All technical terms follow international electrical engineering standards (IEC/NEC).

Brand and model codes remain unchanged as official Schneider part numbers.

Chinese domestic brands (CHINT, DÉLIXI) use widely recognized English spellings in global trade.

Précédent:

Laisser une réponse

Laisser un message