2 poteaux, Courbe de déclenchement de type C, 25Un courant nominal, 6kA pouvoir de coupure, 230/400V AC rated voltage. Suitable for overload and short-circuit protection in residential, commercial and light industrial power distribution systems.
- Model Breakdown
EA9AN2C25 = EA9AN (series code) + 2 (number of poles: 2P.) + C (courbe de déclenchement) + 25 (courant nominal: 25UN)
EA9AN: Standard disjoncteur miniature from Schneider Easy9 series, slim design at 18mm per pole, high space utilization in distribution boards.
2P.: 2-pole protection, disconnects both live and neutral wires for enhanced electrical safety.
C: Type C tripping characteristic, tripping range 5–10×In, suitable for general loads such as lighting and sockets.
25: Rated current 25A, stable operation at 30℃ ambient temperature.
- Key Technical Specifications
| Article | Spécification |
| Tension de fonctionnement nominale (Ue) | 230/400V CA 50 Hz |
| Tension d'isolation nominale (Interface utilisateur) | 500V et |
| Tension de tenue aux impulsions nominale (Ump) | 4kV |
| Rated Breaking Capacity (Icn) | 6000UN (400V et) |
| Caractéristique de déclenchement | Tapez C (5–10In) |
| Courant nominal (Dans) | 25UN (at 30℃) |
| Electrical Endurance | 10,000 operating cycles |
| Mechanical Endurance | 20,000 operating cycles |
| Montage | Montage sur rail DIN (width 2×9mm = 18mm) |
| Connexion | Screw clamp terminals |
| Température ambiante | -30℃ to +70℃ |
| Standards | GB10963 / CEI 60898-1 |
- Caractéristiques du produit & Avantages
- Safe & Reliable: Excellent current-limiting performance reduces fault impact on systems and equipment, improving safety and electrical life.
- Opération facile: Fast make-and-break design minimizes arcing on contacts; intuitive operation, clear fault indication, and simple installation without complex commissioning.
- Rentable: High performance-to-price ratio for residential, retail and small office applications; full series compliant with national standards, flame-retardant and eco-friendly enclosure.
- Conception modulaire: Can be assembled with Easy9 series surge protective devices, over/undervoltage accessories and other modules for expanded protection functions.
- Applications
Residential distribution systems: Protection for lighting and socket circuits in living rooms, chambres à coucher, etc..
Commercial buildings: Installation in distribution boards of small shops and offices.
Light industrial equipment: Auxiliary circuit protection in control cabinets.
Public facilities: Overload and short-circuit protection for lighting systems and small power equipment.
- Sélection & Replacement Recommendations
- Application Matching
Suitable for load circuits with total power ≤5.5kW (230V) or ≤17kW (380V).
Recommended for resistive loads (par exemple. éclairage) and general inductive loads (par exemple. climatiseurs, refrigerators and other household appliances).
- Modèles alternatifs
Upgraded within the same series: EA9AH2C25 (10kA pouvoir de coupure, for higher short-circuit risk environments).
Same-brand alternative: Acti9 series C65N2C25 (performances similaires, compatible dimensions).
Domestic brand alternatives: CHINT NXB-63 2P C25, DELIXI DZ47s 2P C25 (lower cost, comparable performance).
- Installation & Notes d'utilisation
- Avant l'installation, verify the model matches load requirements and check rated current and number of poles.
- Installer au sec, ventilated environments, away from high temperatures, humidity and corrosive conditions.
- Ensure conductors meet specifications during wiring, with proper torque to avoid overheating from loose connections.
- Inspect the breaker regularly to ensure flexible operation, no damage or overheating.
- After a fault trip, identify and resolve the cause before resetting; avoid repeated closing without troubleshooting.
Schneider Easy9 (EA9) Series Model List & Order Numbers
Schneider EA9 (Easy9) series is a product line of miniature circuit breakers and protective devices for residential, commercial and light industrial power distribution, featuring slim design (18mm/pole), cost efficiency and easy installation. Below is the complete model format, specification range and ordering rules by sub-series.
- EA9 Series Naming Convention
EA9XXX[Poteaux][Curve][Current][Suffixe]
| Composant | Description | Options |
| EA9 | Series identifier (Easy9) | Fixé |
| XXX | Sub-series code | AN (standard, 6le), AH (rupture élevée, 10le), R. (RCBO), B/L (SPD), etc.. |
| Poteaux | Nombre de pôles | 1 (1P.), 2 (2P.), 3 (3P.), 4 (4P.), 1+N (1P+N) |
| Curve | Tripping characteristic | C (5–10In, general loads), D (10–14In, power loads), B (3–5In, sensitive electronics) |
| Current | Courant nominal | 6UN,10UN,16UN,20UN,25UN,32UN,40UN,50UN,63UN (AN); 63UN,80UN,100UN,125UN (AH) |
| Suffixe | Special marking | NEW (new version), R. (with indicator), 30C (30mA Type A earth leakage), etc.. |
- EA9AN Series (Standard MCB, 6kA Breaking Capacity)
2.1 Complete Model List
| Poteaux | Curve | Courant nominal | Modèle (Numéro de commande) |
| 1P. | C | 6A/10A/16A/20A/25A /32A/40A/50A/63A | EA9AN1C06, EA9AN1C10, EA9AN1C16, EA9AN1C20, EA9AN1C25, EA9AN1C32, EA9AN1C40, EA9AN1C50, EA9AN1C63 |
| D | 10A/16A/20A/25A /32A/40A/50A/63A | EA9AN1D10, EA9AN1D16, EA9AN1D20, EA9AN1D25, EA9AN1D32, EA9AN1D40, EA9AN1D50, EA9AN1D63 | |
| 2P. | C | 6A/10A/16A/20A /25A/32A/40A/50A/63A | EA9AN2C06, EA9AN2C10, EA9AN2C16, EA9AN2C20, EA9AN2C25, EA9AN2C32, EA9AN2C40, EA9AN2C50, EA9AN2C63 |
| D | 10A/16A/20A/25A /32A/40A/50A/63A | EA9AN2D10, EA9AN2D16, EA9AN2D20, EA9AN2D25, EA9AN2D32, EA9AN2D40, EA9AN2D50, EA9AN2D63 | |
| 3P. | C | 6A/10A/16A/20A /25A/32A/40A/50A/63A | EA9AN3C06, EA9AN3C10, EA9AN3C16, EA9AN3C20, EA9AN3C25, EA9AN3C32, EA9AN3C40, EA9AN3C50, EA9AN3C63 |
| D | 10A/16A/20A/25A/ 32A/40A/50A/63A | EA9AN3D10, EA9AN3D16, EA9AN3D20, EA9AN3D25, EA9AN3D32, EA9AN3D40, EA9AN3D50, EA9AN3D63 | |
| 4P. | C | 6A/10A/16A/20A/ 25A/32A/40A/50A/63A | EA9AN4C06, EA9AN4C10, EA9AN4C16, EA9AN4C20, EA9AN4C25, EA9AN4C32, EA9AN4C40, EA9AN4C50, EA9AN4C63 |
| D | 10A/16A/20A/25A /32A/40A/50A/63A | EA9AN4D10, EA9AN4D16, EA9AN4D20, EA9AN4D25, EA9AN4D32, EA9AN4D40, EA9AN4D50, EA9AN4D63 |
2.2 Order Number Notes
Standard models use the same code for model and order number, par exemple. order number for EA9AN2C25 is EA9AN2C25.
Models with indicator: add suffix “R”, par exemple. EA9AN3C40R.
Packing: 4 pièces/boîte, 32 pcs/carton (standard).
- EA9AH Series (High Breaking MCB, 10kA Breaking Capacity)
3.1 Complete Model List
| Poteaux | Curve | Courant nominal | Modèle (Numéro de commande) |
| 2P. | C | 63A/80A/100A/125A | EA9AH2C63NEW, EA9AH2C80NEW, EA9AH2C100NEW, EA9AH2C125NEW |
| D | 63A/80A/100A/125A | EA9AH2D63NEW, EA9AH2D80NEW, EA9AH2D100NEW, EA9AH2D125NEW | |
| 3P. | C | 63A/80A/100A/125A | EA9AH3C63NEW, EA9AH3C80NEW, EA9AH3C100NEW, EA9AH3C125NEW |
| D | 63A/80A/100A/125A | EA9AH3D63NEW, EA9AH3D80NEW, EA9AH3D100NEW, EA9AH3D125NEW | |
| 4P. | C | 63A/80A/100A/125A | EA9AH4C63NEW, EA9AH4C80NEW, EA9AH4C100NEW, EA9AH4C125NEW |
| D | 63A/80A/100A/125A | EA9AH4D63NEW, EA9AH4D80NEW, EA9AH4D100NEW, EA9AH4D125NEW |
3.2 Order Number Notes
New models carry the “NEW” suffix, par exemple. EA9AH4D100NEW.
Packing: 3 pièces/boîte, 18 pcs/carton.
- EA9R Series (Disjoncteur à courant résiduel, RCBO)
4.1 Complete Model List (1P+N / 2P. / 3P. / 4P.)
| Poteaux | Curve | Courant nominal | Earth Leakage | Modèle (Numéro de commande) |
| 1P+N | C | 16A/20A/25A/32A /40A/50A/63A | 30mA Type A | EA9RN1C1630CAR, EA9RN1C2030CAR, EA9RN1C2530CAR, EA9RN1C3230CAR, EA9RN1C4030CAR, EA9RN1C5030CAR, EA9RN1C6330CAR |
| 2P. | C | 16A/20A/25A/32 A/40A/50A/63A | 30mA Type A | EA9RN2C1630C, EA9RN2C2030C, EA9RN2C2530C, EA9RN2C3230C, EA9RN2C4030C, EA9RN2C5030C, EA9RN2C6330C |
| 3P. | C | 16A/20A/25A/32A /40A/50A/63A | 30mA Type A | EA9RN3C1630C, EA9RN3C2030C, EA9RN3C2530C, EA9RN3C3230C, EA9RN3C4030C, EA9RN3C5030C, EA9RN3C6330C |
| 4P. | C | 16A/20A/25A/32A /40A/50A/63A | 30mA Type A | EA9RN4C1630C, EA9RN4C2030C, EA9RN4C2530C, EA9RN4C3230C, EA9RN4C4030C, EA9RN4C5030C, EA9RN4C6330C |
4.2 Order Number Notes
RCBO model format: EA9RN[Poteaux][Curve][Current][Leakage][Taper]
Leakage rating: 30C = 30mA Type A (standard); 30CAR = 30mA Type A with indicator.
Packing: 20 pcs/carton (standard).
- Overview of Other EA9 Sub-Series
| Sub-Series | Type de produit | Principales fonctionnalités | Modèle typique |
| EA9B/EA9L | Dispositif de protection contre les surtensions (SPD) | Lightning & surge protection, for main/end distribution | EA9B208, EA9L208 (2P 8kA) |
| EA9C | Modular Contactor | For control circuits, 2NO/2NC contacts | EA9C20116 (2P 16A 2NO 220V) |
| EA9 Accessories | Over/Undervoltage / Déclenchement de dérivation | Assembled with EA9 breakers | EA9XU2 (2P over/undervoltage accessory) |
- Sélection & Replacement Advice
- EA9AN vs EA9AH
EA9AN (6le): For standard residential and commercial distribution.
EA9AH (10le): For industrial environments and high short-circuit risk locations.
- Replacement Options
Same-brand upgrade: Acti9 series C65N2C25 (performances similaires, dimensionally compatible).
Domestic alternatives: CHINT NXB-63 2P C25, DELIXI DZ47s 2P C25 (lower cost).
- Ordering Tips
New models (par exemple. EA9AH series) are marked with “NEW”; old versions are being phased out.
Confirm number of poles, tripping curve and rated current before ordering to avoid mismatches.
Translation Notes
All technical terms follow international electrical engineering standards (IEC/NEC).
Brand and model codes remain unchanged as official Schneider part numbers.
Chinese domestic brands (CHINT, DÉLIXI) use widely recognized English spellings in global trade.
Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires


















NH42-63-318x560.png)