Disjoncteur miniature Schneider EA9AN4C63

MarqueModèle de remplacement
ABBS204‑C63
Siemens5SY6463‑7CC
CHINTNXB‑63 4P C63
DélicieuxCDM30s‑63 4P C63
Schneider upgradeA9F94463 (Série Acti9)

  • Détails du produit

Schneider Easy9 series 4‑pole 63A C‑curve disjoncteur miniature, used for overload and short‑circuit protection in three‑phase four‑wire distribution systems. DIN‑rail mountable, suitable for final distribution in residential, commercial and light industrial applications.

1 Explication du modèle

PartieSignification
EA9ANEasy9 series standard MCB
44 poteaux (3 étapes + N), all poles with protection function
CC tripping curve (5–10In instantaneous trip), suitable for lighting and resistive/slightly inductive mixed loads
63Rated current 63A (at 30°C ambient)

2 Paramètres techniques clés

ParamètreValeurDescription
Rated operational voltage230/400V etSuitable for single‑/three‑phase systems
Tension d'isolement nominale400V et-
Fréquence nominale50/60HZUniversal frequency
Rated breaking capacity6le (400V)Standard breaking capacity for general distribution
Tripping typeThermique-magnétiqueThermal overload protection + magnetic short‑circuit protection
Courbe de déclenchementC‑curveInstantaneous trip range: 5–10 pouces, moderate inrush current withstand
Nombre de pôles4P.4 protected poles, neutral on the left
Montage35mm rail DINStandard electrical cabinet mounting
Endurance électrique10,000 opérationsRated operating cycles
Endurance mécanique20,000 opérationsMechanical operating cycles
DimensionsEnviron. 85mm×78.5mm×18mm (4‑pole width)Standard 4‑pole MCB size
StandardsGB16917/IEC60898National and international standards

3 Fonctions principales & Caractéristiques

  1. Protection contre les surcharges: Thermal trip unit acts with current‑time accumulation to prevent overheating and burnout.
  2. Short‑circuit protection: Magnetic trip unit operates instantaneously (<0.1s) to clear short‑circuit current and protect equipment and wiring.
  3. Fonction d'isolement: Complies with EN/IEC 60947‑2, can be used as an isolating device.
  4. Quick make: Internal mechanism ensures fast circuit closing.
  5. Operation indication: Clear ON/OFF status indication for easy maintenance.
  6. Safety design: Anti‑misoperation structure, high insulation performance, safe and reliable.

4 Applications typiques

Residential distribution: Main incoming breaker for three‑phase four‑wire homes, protecting the entire electrical system.

Commercial buildings: Floor or zone main breaker in offices, centres commerciaux, hôtels, etc..

Light industry: Branch circuit protection for workshops and production lines, suitable for mixed motor, lighting and socket loads.

Final distribution: Dedicated protection for three‑phase equipment (climatiseurs, pompes, small machine tools).

5 Cross‑Brand Replacement Reference

MarqueModèle de remplacementRemarques
ABBS204‑C63Same 4P C63A, 6kA pouvoir de coupure
Siemens5SY6463‑7CC4P C63A, pouvoir de coupure standard
CHINTNXB‑63 4P C63Alternative nationale, rentable
DélicieuxCDM30s‑63 4P C63Similar performance, compatible with domestic panels
Schneider upgradeA9F94463 (Série Acti9)Breaking capacity up to 15kA, performances améliorées

6 Installation & Notes de sélection

  1. Installation precautions

Must be mounted on 35mm standard DIN rail, installation depth ≥78.5mm

Terminal suitable for copper conductors: 1.5–35mm²

Neutral must be connected to the designated left terminal – do not reverse.

  1. Selection recommendations

Total three‑phase load current ≤63A, suitable for C‑curve loads (not heavy motor starting).

For distribution systems with short‑circuit current >6le, upgrade to higher breaking capacity models (par ex., Série Acti9).

Derate at ambient temperature >30°C: current reduced by 1% per °C rise.

Schneider EA9AN4C63 vs Acti9 A9F94463 Full Comparison & Upgrade Recommendation

At a glance: A9F94463 (iC60L series) is superior to EA9AN4C63 in breaking capacity, compactness, accessory expandability, and electrical/mechanical endurance, suitable for higher short‑circuit risk and higher reliability/expandability requirements.

EA9AN4C63 is more economical and meets basic protection for standard residential and light commercial use.

1 Core Parameter Comparison

ParamètreEA9AN4C63 (Easy9)A9F94463 (Acti9 iC60L)Key Difference
Series positioningEconomic standardHigh‑performance standardA9 higher‑end, richer functions
Poles/Current/Curve4P. / 63UN / C‑curve4P. / 63UN / C‑curveBasic specs identical
Rated breaking capacity6le (400V)15le (400V)A9 ×2.5 higher, stronger short‑circuit withstand
Tension d'isolement nominale400V et400V etSame
Rated operational voltage230/400V et230/400V etSame
Tripping typeThermique-magnétiqueThermique-magnétiqueSame
Montage35mm rail DIN35mm rail DINSame
Dimensions85mm×78.5mm×18mm (4P.)85mm×44.5mm×18mm (4P.)A9 depth –43%, saves panel space
Capacité de câblage1.5–35mm² (copper)1.5–35mm² (copper), dual tunnel terminalsA9 more secure, same conductor range
Endurance électrique10,00015,000A9 +50%
Endurance mécanique20,00025,000A9 +25%
Protection degreeIP20IP20 (terminal IP20B)A9 better terminal protection
Compatibilité des accessoiresBasic accessories (aux./shunt)Full Acti9 range (aux., shunter, UVP, remote, etc.)A9 more expandable, supports Ti24
StandardsGB16917/IEC60898GB16917/IEC60898/IEC60947‑2A9 covers more standards
Price rangeEnviron. ¥150–200Environ. ¥350–500A9 ~2–2.5× EA9 price

2 Detailed Performance Differences

2.1 Capacité de coupure: Core Safety Gap

EA9AN4C63: 6le, suitable for general systems with short‑circuit current ≤6kA.

A9F94463: 15kA high breaking capacity, reliably clears higher short‑circuit currents, reduces arc risk.

Suitable for:

Industrial plants, large commercial buildings

Distribution circuits near transformers

Systems where short‑circuit current may exceed 6kA

2.2 Conception compacte: Better Space Utilization

A9F94463 depth only 44.5mm, greatly reduced from EA9AN4C63 78.5mm.

Benefits:

Fits slimmer distribution boards/cabinets

Saves installation space, eases maintenance

Ideal for retrofit projects with limited space

2.3 Endurance & Fiabilité: Longer‑Term Stability

Electrical endurance from 10k → 15k operations; mechanical 20k → 25k.

A9 series uses higher‑grade materials and precision manufacturing for better long‑term stability.

Better vibration and impact resistance for harsh environments.

2.4 Accessory Expandability: Flexible Function Upgrades

EA9AN: Supports only basic auxiliary contacts and shunt trips.

A9F94463: Supports full Acti9 accessory range:

Multi‑function auxiliary / contacts d'alarme

Remote‑control shunt trips

Over/undervoltage protection modules

Auto‑reclose accessories

Ti24 interface for PLC/BMS integration

3 Upgrade Decision Guide

Recommended to upgrade to A9F94463 if:

  1. Calculated short‑circuit current >6le
  2. Critical facilities: industriel, large commercial, hospital, data center
  3. Future expansion needed (télécommande, voltage monitoring, etc.)
  4. Limited panel space requires compact solution
  5. Higher reliability and longer service life required to reduce maintenance cost

Recommended to keep EA9AN4C63 if:

  1. Standard residential / small shop loads, short‑circuit ≤6kA
  2. Budget‑sensitive, priorité aux coûts
  3. Basic protection only, no complex accessories
  4. Already installed EA9 panel with matching system parameters

4 Notes de remplacement

  1. Direct interchangeability: Both 4P C63A, DIN‑rail mount – direct replacement.
  2. Wiring check: A9F94463 neutral position matches EA9AN (left) – no need to reorder wiring.
  3. Derating: Both derate at >30°C (–1% per °C).
  4. Compatibilité des accessoires: Existing EA9 accessories must be replaced with Acti9‑specific versions.

Précédent:

Suivant:

Laisser une réponse

Laisser un message