Part Number Breakdown & Product Positioning EA9RN3C3230CA is a 3‑pole integrated Residual Current Circuit Breaker with Overcurrent protection (RCBO) from Schneider Electric’s Easy9 series (EA9R). It provides threefold protection: surcharge, short‑circuit, and earth‑leakage protection, suitable for final distribution systems in residential, commercial, et applications industrielles légères. Part Segment Description EA9R Easy9 series RCBO N Standard ...

  • Détails du produit

Part Number Breakdown & Positionnement du produit

EA9RN3C3230CA is a 3‑pole integrated Disjoncteur à courant résiduel with Overcurrent protection (RCBO) from Schneider Electric’s Easy9 series (EA9R).

It provides threefold protection: surcharge, short‑circuit, and earth‑leakage protection, suitable for final distribution systems in residential, commercial, et applications industrielles légères.

Part SegmentDescription
EA9REasy9 series RCBO
NStandard breaking capacity (6 kA)
3Nombre de pôles (3P.), three‑phase protection
CTripping curve type, pour charges générales (éclairage, prises)
32Courant nominal: 32 A
30Residual current sensitivity: 30 mA, for personal electric shock protection
CAType‑A leakage protection, detects AC and pulsating DC leakage for modern electronic loads
  1. Key Electrical Specifications
ParamètreSpécification
Rated operational voltage230/400 V AC, three‑phase four‑wire system
Tension d'isolement nominale600 V AC
Rated impulse withstand voltage4 kV
Courant nominal (Dans)32 A
Courbe de déclenchementTapez C, magnetic tripping range: 5–10 × In
Pouvoir de coupure (Icn)6 kA (at 400 V)
Residual current sensitivity (JeΔn)30 mA, fast operation (≤ 0.1 s)
Leakage protection typeType‑A, detects AC and pulsating DC leakage
Fréquence nominale50/60 Hz
Fonction d'isolementComplies with IEC standards, provides isolation
  1. Caractéristiques & Benefits
  2. Threefold protection: Surcharge, short‑circuit, and earth‑leakage protection for comprehensive electrical safety.
  3. Type‑A leakage detection: Suitable for pulsating DC leakage from modern electronic equipment (alimentations à découpage, inverters, etc.).
  4. Clear status indication: Handle and contact position indication for quick status judgment.
  5. Reliable mechanical performance: Mechanical life ≥ 20,000 operations; electrical life ≥ 5,000 operations.
  6. Installation facile: Standard 35 mm DIN‑rail mounting with locking clamps.
  7. Eco‑friendly: Mercury‑free, complies with EU RoHS and China RoHS; part of Schneider Green Premium.
  8. Wide operating temperature: -25 °C to +60 °C.
  9. Installation & Maintenance Guide

Exigences d'installation

Montage: Standard 35 mm DIN‑rail; width = 3 modules (54 mm); height = 117 mm.

Capacité de câblage:

Haut: M5 terminal, max 25 mm² flexible cable

Bas: M6.5 terminal, max 25 mm² flexible / 35 mm² semi‑rigid / câble solide

Environnement: Dust‑free, sec, non‑corrosive, low vibration; installation altitude ≤ 2000 m.

Sécurité: Must be installed by a qualified electrician in accordance with GB 16917 and IEC 61009.

Entretien

  1. Operate ON/OFF monthly to check mechanical function.
  2. Test leakage protection quarterly using the TEST button.
  3. Après un déclenchement sur défaut, resolve the cause before resetting.
  4. Avoid frequent unnecessary operation.
  5. Clean with dry cloth only when power is off; no chemical cleaners.
  6. Remplacement & Upgrade Options

Same‑Series Replacements

ModèleDifferenceApplication
EA9RN3C3230CRNew marking, identical performanceStock replacement
EA9RN3C3230CNEWNew naming, same performanceProduct iteration
EA9RN3C32100CA100 mA sensitivity, for equipment protectionMoteurs, pompes

Upgraded Models (Higher Performance)

SérieModèle typiqueMain Improvements
A9 ProA9P323230Smart monitoring, télécommande, fault diagnostics
Acti9 iIDA9R26332Selective protection, 10 kA breaking capacity, longer life

Cross‑Brand Compatible Replacements

MarqueModèle de remplacementCompatibilité
Siemens5SU9356‑3CR32Identical electrical & mounting dimensions
ABBGS201 A‑C32/0.03Equivalent protection, Type‑A, 32 A/30 mA, DIN‑rail
ChintNXBLE‑32‑3P‑C32/0.03ACost‑effective direct replacement
  1. Applications & Conseils de sélection

Applications typiques

Three‑phase power circuits in residential/commercial buildings (AC units, pompes, les fans)

Final distribution for light industrial equipment (machine tools, machines d'emballage)

Input protection for PV inverters, UPS, and power electronics

Hospitals, data centers, and high‑safety locations

Selection Guidelines

  1. Verify voltage (230/400 V) and frequency (50/60 Hz).
  2. Choose tripping curve: Type C for general loads.
  3. Courant nominal: 32 A suitable for three‑phase loads ≤ 7 kW.
  4. Use Type‑A for systems with electronic equipment.
  5. 6 kA breaking capacity suits most final circuits; upgrade to 10 kA near transformers.
  6. Approvals & Conformité

Standards: GB 16917 / IEC 61009

Certifications: CCC, CE

Environnement: EU RoHS, China RoHS, REACH compliant

Warranty: 3‑year official Schneider warranty under normal use

EA9RN3C3230CA is a reliable, easy‑to‑install 3‑pole, 32 A, 30 mA, Type‑A RCBO from the Schneider Easy9 series. It provides comprehensive protection for final distribution applications. Suppliers can recommend same‑series replacements, upgrade to A9 Pro / Acti9 iID, or offer cross‑brand alternatives based on project requirements.

Cross‑Brand & Equivalent Model List for Schneider EA9RN3C3230CA

  1. Full List of Equivalent Models

(EA9RN series, 3P., 32 A, 30 mA, Type‑A RCBO)

ModèleDescriptionKey SpecsRemarques
EA9RN3C3230CAStandard model3P., C32A, 30mA, Type‑A, 6leBase version
EA9RN3C3230CRNew marking3P., C32A, 30mA, Type‑A, 6leLabel update only
EA9RN3C3230CNEWNew naming3P., C32A, 30mA, Type‑A, 6lePerformance unchanged
EA9RN3C3230CARRegional variant3P., C32A, 30mA, Type‑A, 6leRegional supply

Other Current Ratings (3P., 30 mA, Type‑A)

ModèleCourant nominalApplication
EA9RN3C1030CA10 ASmall three‑phase loads
EA9RN3C1630CA16 ASmall/medium equipment
EA9RN3C2030CA20 AGeneral power circuits
EA9RN3C2530CA25 AMedium power loads
EA9RN3C4030CA40 AHeavy three‑phase loads
EA9RN3C5030CA50 AHigh‑power equipment
EA9RN3C6330CA63 AMain switches / large machinery
  1. Cross‑Brand Cross‑Reference

(3P., 32 A, 30 mA, Type‑A RCBO, direct interchangeable)

MarqueModèleCourant nominalSensitivityBreakingCompatibilité
Siemens5SU9356‑3CR3232 A30 mA6 kAEntièrement compatible
Siemens5SU9356‑3CR32NEW32 A30 mA6 kANew version
ABBGS201 A‑C32/0.0332 A30 mA6 kARemplacement direct
ABBS201‑C32 A‑0.0332 A30 mA6 kACompact design
ChintNXBLE‑32‑3P‑C32/0.03A32 A30 mA6 kACost‑effective
NaderNDBLE‑32‑3P‑C32/0.03A32 A30 mA6 kAReliable domestic
DélicieuxCDL7‑32‑3P‑C32/0.03A32 A30 mA6 kAEconomic option
Commutateur ChangshuCH3L‑32‑3P‑C32/0.03A32 A30 mA6 kAIndustrial grade
  1. Full Naming Convention for EA9RN Series
SegmentSignificationOptions
EA9RSérieEasy9 RCBO
NPouvoir de coupureN = 6 kA
3Poteaux1P., 2P., 3P., 4P., 1P+N
CCourbe de déclenchementC = general; D = motor / heavy load
32Courant nominal6, 10, 16, 20, 25, 32, 40, 50, 63 A
30Leakage sensitivity30 mA (personal); 100 mA (equipment)
CALeakage typeCA = Type‑A; AC = Type‑AC
  1. Notes de sélection
  2. Leakage type: Use Type‑A for systems with inverters, alimentations à découpage.
  3. Pouvoir de coupure: 6 kA for most final circuits; 10 kA near transformers.
  4. Dimensions: 35 mm DIN‑rail; 3P = 3 modules (54 mm).
  5. Attestation: Use CCC‑approved products in China.
  6. Brand consistency: Prefer same brand in one system to avoid unwanted tripping.
  7. Remplacement & Upgrade Path

Upgrades Within Schneider

SérieModèleImprovementsApplication
Acti9 iIDA9R26332Selective protection, 10 kACommercial & industriel
A9 ProA9P323230Smart monitoring, télécommandeSmart buildings, data centers

Cross‑Series Drop‑In Replacements

EA9RN3C3230CA ↔ EA9RN3C3230CR (new marking)

For higher breaking: EA9RH3C3230CA (10 kA), same dimensions

The Schneider EA9RN3C3230CA is a robust 3P, 32 A, 30 mA, Type‑A RCBO. Equivalent models include EA9RN3C3230CR and EA9RN3C3230CNEW.

Top cross‑brand direct replacements:

Siemens 5SU9356‑3CR32, ABB GS201 A‑C32/0.03, Chint NXBLE‑32‑3P‑C32/0.03A.