Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

Schneider Electric NSX250N‑3P‑160A - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

disjoncteur/

Schneider Electric NSX250N‑3P‑160A

This is a Schneider Electric ComPacT NSX series molded case circuit breaker (MCCB) for power distribution protection. New standard order number: C25N3TM160 Obsolete old order number: LV431832 Compliant with IEC 60947‑2 and GB/T 14048.2 normes. Basic Rated Core Parameters Item Value Type Low‑voltage MCCB for power distribution protection Frame rating 250A Poles 3P (3 poteaux, ...

  • Détails du produit

This is a Schneider Electric ComPacT NSX series disjoncteur à boîtier moulé (MCCB) for power distribution protection.

New standard order number: C25N3TM160

Obsolete old order number: LV431832

Compliant with IEC 60947‑2 and GB/T 14048.2 normes.

  1. Basic Rated Core Parameters
ItemValeur
TaperLow‑voltage MCCB for power distribution protection
Frame rating250UN
Poles3P. (3 poteaux, all protected)
Rated current In160UN (continuous at 40℃)
Rated operational voltage Ue690V AC 50/60Hz, suitable for 380V/400V/415V systems
Rated insulation voltage Ui800V et
Rated impulse withstand voltage Uimp8kV
Fréquence50/60Hz
Utilization categoryType A (no short‑time delay, general distribution)
Isolation functionCertified isolating function per IEC 60947‑2
  1. Short‑Circuit Breaking Capacity
System VoltageRated ultimate shortircuit breaking capacity IcuRated service shortircuit breaking capacity Ics
415V et50le50le (100% ICU, reusable after breaking)
500V et36le36le
690V et10le10le

Rated short‑time withstand current Icw (1s): 12kA at 415V AC

  1. TMD Thermal‑Magnetic Release Characteristics

Standard TMD thermal‑magnetic release, LI protection (long‑time overload + instantaneous short‑circuit).

  1. Long‑time overload thermal protection

Ir setting range: 0.7–1×In (112A–160A)

Characteristic: 120–400s at 1.5×Ir; ≤15s at 6×Ir (standard inverse time)

  1. Short‑circuit instantaneous magnetic protection

Instantaneous current Ii: fixed at 1250A

Operating time: ≤20 ms

  1. Mechanical & Installation Parameters
ItemValeur
Dimensions (L×H×P)105mm × 161mm × 86mm
Standard mounting centersVertical 125mm × Horizontal 35mm
MontageFixé, front connected; horizontal/vertical, no derating
Wiring capacityUp to 70mm² copper cable / busbar
Mechanical endurance20,000 opérations
Electrical endurance10,000 operations at 440V AC, Dans
Ingress protectionIP40 (body), IP54 (panel‑mounted)
Impact resistanceIK07
Net weightApprox. 2.4kg
  1. Environmental & Compliance Parameters

Ambient temperature: -25℃ ~ +70℃; no derating below 40℃

Altitude: 0–2000m without derating

Degré de pollution: 3

Overvoltage category: II

Certifications: CCC, CE, CAE, Marine, etc..

Accessory slots: 5 standard slots for auxiliary, alarm, shunt, déclencheur à minimum de tension, etc..

  1. Expansion & Compatibilité

Can be fitted with Vigi earth‑leakage modules

Compatible with motor operators for remote control

Can add interlock, position indicator, padlock devices

Top/bottom feed both allowed without performance derating

Replacement & Notes de sélection

  1. Old type LV431832 is discontinued; use C25N3TM160 instead.
  2. For electronic release (adjustable short delay / earth fault), upgrade to NSX250N with MicroLogic (2.2/5.0).
  3. Breaking ratings: H (70le), S (100le), based on short‑circuit calculation.
  4. Competitors: ABB Tmax T2, Siemens 3VT250, suitable for cross‑brand replacement.

NSX250N‑3P‑160A Direct Replacement Solutions

Core Matching Rules (100% match required)

Frame rating: 250UN (do NOT downgrade to 160A frame)

Poles: 3P.

Courant nominal: 160UN

Pouvoir de coupure: ≥50kA at 415V AC

Release type: thermal‑magnetic (LI characteristic)

Montage: fixed front connection, matching panel holes

  1. Recommended Replacements

Scénario 1: Import Brand Direct Replacement

ABB Tmax XT3N250 TMD160/1600 FF 3P

Order No.: 1SDA068266R1

Match: 100%

Frame 250A, 3P., 160UN, TMG thermal‑magnetic

Icu = 50 kA, Ics=50kA at 415V AC

Identical dimensions and mounting holes

Full accessory compatibility

Application: foreign‑funded plants, export equipment, on‑site repair

Siemens 3VC250N TMA160 3P

Order No.: 3VC2316‑2DA33‑0AA0

Match: 98%

Frame 250A, 3P., 160UN, TMA thermal‑magnetic

50kA at 415V AC

Highly compatible dimensions

Application: Siemens low‑voltage systems

Scénario 2: Domestic High‑Cost‑Performance Replacement

Changshu Switch CM3‑250H/3300 160A

Match: 99%

Frame 250A, 3P., 160UN, distribution type thermal‑magnetic

Icu=50kA at 415V AC

Compliant with IEC 60947‑2 / FR 14048.2

Application: industrial, building distribution, domestic projects

Chint NM8‑250N/3P 160A

Match: 95%

Frame 250A, 3P., 160UN, thermal‑magnetic

50kA at 415V AC

Application: civil construction, general distribution

  1. Dimensions & Parameters Comparison
ModèleDimensions (L×H×P)Mounting CentersICU (415V)ReleaseFrame
NSX250N‑3P‑160A105×161×86mm125mm×35mm50leTMD250UN
ABB XT3N250 3P 160A105×161×86mm125mm×35mm50leTMG250UN
Siemens 3VC250N 3P 160A105×160×85mm125mm×35mm50leTMA250UN
CM3‑250H 3P 160A108×162×86mm125mm×35mm50leThermal‑magnetic250UN

> Note: ABB XT3N250 matches dimensions and holes 100% – best direct replacement.

  1. Safety Rules for Replacement
  2. No frame downgrade: Do NOT use 160A frame breakers (par ex., ABB T2N, NSX160).
  3. Breaking capacity ≥50kA: Do NOT use 36kA / 25kA models.
  4. Release matching: Use distribution‑type thermal‑magnetic only.
  5. Compatibilité des accessoires: Match auxiliary, shunt, sous-tension, earth‑leakage modules.
  6. Final Selection Guide

Remplacement direct, import, no cabinet modification: ABB XT3N250 TMD160/1600 FF 3P

New project, domestic approval, cost‑effective: Changshu CM3‑250H/3300 160A

Siemens system replacement: Siemens 3VC250N TMA160 3P

Précédent:

Laisser une réponse

Laisser un message