- In-depth Model Interpretation
| Segment de modèle | Description |
| XCKN | Product family: OsiSense XC standard limit switch, compact Type A, plastic housing |
| 2 | Connection type: screw clamp terminals, suitable for 1×0.34mm²~2×1.5mm² wires |
| 1 | Contact configuration: 1 Normalement ouvert (NON) + 1 Normalement fermé (Caroline du Nord), snap action |
| 18 | Actuator type: thermoplastic roller lever, spring return, side actuation |
| P20 | Cable entry: M20×1.5 thread, suitable for cables with outer diameter 7~13mm |
| C | Certification mark: compliant with Chinese CCC certification, suitable for domestic market |
- Paramètres techniques de base
Paramètres électriques
Rated operational voltage: AC 240V, DC 125V
Rated operational current: 10UN (AC-15: 3A at 240V)
Contact type: 1NON + 1Caroline du Nord, contacts en alliage d'argent
Mechanical durability: 10,000,000 opérations
Electrical durability: 100,000 opérations (AC-15)
Minimum actuation torque: 0.1Nm, actuated with low operating force
Mécanique & Environmental Parameters
Protection contre la pénétration: IP65 (CEI 60529), dust-tight and water-resistant
Insulation class: Class II (CEI 61140)
Température de fonctionnement: -25°C ~ +70°C
Storage temperature: -40°C ~ +70°C
Vibration resistance: 25gn (10~500Hz), conforme à la CEI 60068-2-6
Shock resistance: 45gn (11MS), conforme à la CEI 60068-2-27
Montage: Body mounting, suitable for 24/40mm rails
Dimensions: 108mm×58mm×36mm (L×L×H)
- Caractéristiques du produit & Avantages
- Structural Benefits
All-plastic housing, lightweight (environ. 120g), excellent corrosion resistance
30° cam actuation design for precise triggering and reduced misoperation
Roller lever can be installed with 360° rotation to adapt to various mounting angles
- Performance Assurance
Snap-action contacts (≤10ms) for fast signal response
Double-break contact design for improved breaking reliability
Built-in surge suppression circuit to protect control circuits
- Safety Certifications
Multiple certifications including CCC, UL, CSA for global use
Compliant with EN 50047, interchangeable with products to the same standard
- Applications typiques
| Application Field | Specific Usage |
| Automated production lines | Position detection for robotic arms, conveyor positioning, workpiece in-position confirmation |
| Logistics & warehousing | Stacker limit protection, rack telescopic positioning, AGV path control |
| Lifting equipment | Elevator/goods lift upper/lower limits, lifting platform travel control, forklift lifting height restriction |
| Machines d'emballage | Bag sealer cutting position, labeling machine positioning, cartoner in-position detection |
| Machine tools | Table travel limitation, tool change position detection, safety door interlock |
| Construction machinery | Crane limit protection, concrete mixer level control, elevator door safety detection |
- Installation & Guide de câblage
Étapes d'installation
- Select a flat and rigid mounting surface with sufficient operating space (≥50mm)
- Secure with M4 bolts (torque 2.5Nm) or mount on 24/40mm standard rails
- Adjust roller orientation to ensure proper contact with actuating parts (recommended contact angle 30°)
- Install M20 cable gland to maintain IP65 protection
Spécifications de câblage
Incoming wire: 1×0.34mm²~2×1.5mm² stranded or solid wire
Terminal torque: 0.8Nm, avoid over-tightening to prevent damage
Separate high-voltage (>24V) and low-voltage (<24V) control circuits to reduce interference
For long-distance wiring (>10m), shielded cable with single-end grounding is recommended
- lternative Models & Compatibility Solutions
Alternatives within Schneider Series
XCKN2118P12C: M12×1.5 cable entry, suitable for 4~8mm cables
XCKN2118G11C: PG11 cable entry, suitable for 6~12mm cables
XCKN2118P20: International version (without C mark), for export projects
Alternatives multimarques
| Marque | Alternative Model | Compatibilité |
| Omron | D4C-1320 | ★★★★☆ (Same electrical parameters, slight differences in mounting dimensions) |
| Siemens | 3SE5 232-0CH01 | ★★★★☆ (Protection IP65, identical contact configuration) |
| ABB | LS35M-11 | ★★★★☆ (Same actuator type, matching actuation torque) |
- Sélection & Purchasing Guidelines
- Three Key Selection Factors
Actuation type: confirm side or front actuation to select the corresponding actuator
Cable specification: choose M20/M12/PG11 entry based on on-site cable outer diameter
Circuit de commande: select rated voltage model for AC/DC systems accordingly
- Purchasing Tips
Look for original Schneider packaging; XCKN series has unique anti-counterfeit codes verifiable on the official website
Avoid bulk or loose-pack products; items without CCC certification are prohibited for domestic use
Require suppliers to provide product certificates and type test reports
- Garantie & After-Sales Service
Standard warranty period: 18 mois
Fault response: technical support from authorized Schneider service providers within 48 heures
Repair & replacement: free replacement for non-artificial damage
- Dépannage
| Symptom | Cause possible | Solution |
| Contacts do not actuate | Insufficient actuation force | Adjust mounting position to ensure actuation torque ≥0.1Nm |
| Contacts welded closed | Overcurrent operation | Check control circuit current to ensure it is within rated value |
| Loss of protection | Loose cable gland | Retighten M20 connector and replace damaged sealing ring |
| Signal fluctuation | Poor wiring connection | Check terminal torque and re-crimp wires |
Selection Recommendation:
XCKN2118P20C is a highly versatile standard limit switch, especially suitable for position detection and safety protection in automation equipment, logistics systems and construction machinery. For special environmental applications, stainless steel housing (XCKJ series) or high-temperature resistant type (XCKT series) peut être considéré.
Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires
















NH42-63-318x560.png)