Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

Siemens 3VT8-63H102 Molded Case Circuit Breaker (MCCB) - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

disjoncteur/

Siemens 3VT8-63H102 Molded Case Circuit Breaker (MCCB)

Model SegmentSpeculative MeaningDescription
3VT8Siemens SENTRON 3VT8 Series Molded Case Circuit BreakerDiscontinué, replaced by 3VA/3VM/3VC series
63Courant nominal (Dans): 63UNMaximum current for long-term operation at 40掳C ambient temperature
HBreaking Capacity Class: Class H (50le)Breaking capacity classes of 3VT8 series: Class N (25le), Class H (50le), Class L (65le)
102Speculated as a combination of frame current + pole number/trip unit type100A frame (VT100), 2-pole configuration, Thermal-Magnetic Trip unit (TMF)

  • Détails du produit

Model Designation Interpretation (Speculative, Based on 3VT8 Series Naming Rules)

The model “3VT8-63H102provided by the user is a simplified version; the complete model usually contains more detailed information. The speculative meaning of each part is as follows:

Model SegmentSpeculative MeaningDescription
3VT8Siemens SENTRON 3VT8 Series Molded Case Circuit BreakerDiscontinué, replaced by 3VA/3VM/3VC series
63Courant nominal (Dans): 63UNMaximum current for long-term operation at 40掳C ambient temperature
HBreaking Capacity Class: Class H (50le)Breaking capacity classes of 3VT8 series: Class N (25le), Class H (50le), Class L (65le)
102Speculated as a combination of frame current + pole number/trip unit type100A frame (VT100), 2-pole configuration, Thermal-Magnetic Trip unit (TMF)

Most Probable Corresponding Complete Models: 3VT8106-1AA03-0AA0 (3-pôle, 63UN, Class H breaking capacity, TMF trip unit) or 3VT8106-1AA04-0AA0 (4-pôle)

  1. Core Specification Parameters (Based on 3VT8 100H 63A TMF)
Élément de paramètreSpecification ValueDescription
Type de produitMolded Case Circuit Breaker (MCCB)Used for overload and short-circuit protection in power distribution systems
Frame Current (Iu)100UNVT100 frame, compatible with a maximum rated current trip unit of 63A
Courant nominal (Dans)63UNRated operating current at 40掳C ambient temperature
Ultimate Breaking Capacity (ICU)50le (415/440V et)Class H breaking capacity, meeting the requirements of industrial power distribution systems
Trip Unit TypeThermal-Magnetic Trip unit (TMF)Protection contre les surcharges (thermal element): inverse time characteristic; Protection contre les courts-circuits (magnetic element): instantaneous tripping
Numéro de pôle3-pole or 4-pole3-pole is commonly used in power distribution systems; 4-pole is adopted when neutral wire protection is required
Rated Operational Voltage (Ue)400/415V etSuitable for three-phase industrial power distribution systems
Tension d'isolation nominale (Interface utilisateur)690V etCompliant with IEC 60947-2 standard
Température de fonctionnement-25C ~ +70CDerating is required when the temperature exceeds 40C
Méthode de câblageFront Panel WiringRear panel wiring or plug-in connection is optional
Méthode de fonctionnementRotary HandleElectric operating mechanism is optional for remote control

III. Product Features and Advantages

  1. Haute fiabilité: A member of Siemens SENTRON series, compliant with the international IEC 60947-2 standard.
  2. Capacité de coupure élevée: Class H 50kA breaking capacity, effectively interrupting short-circuit faults and protecting equipment safety.
  3. Configuration flexible: Compatible with a variety of accessories (contacts auxiliaires, alarm contacts, shunt release, déclencheur à minimum de tension, etc.).
  4. Safety Design: Lockable rotary operating mechanism to prevent misoperation; Terminal cover protection for enhanced safety.
  5. Taille compacte: Saving switchgear space, facilitating installation and maintenance.
  6. Scénarios d'application typiques
  7. Industrial Power Distribution Systems: Used as incoming/outgoing circuit breakers in distribution boxes to protect cables and lines.
  8. Motor Protection: Serves as protection equipment for direct starting of three-phase squirrel-cage motors, offrant une protection contre les surcharges et les courts-circuits.
  9. Transformer/Capacitor Protection: Protecting distribution transformers and compensation capacitors to prevent fault expansion.
  10. Main Switch/Emergency Stop Switch: Combined with a lockable operating mechanism, used as the main switch and emergency stop control for equipment or systems.
  11. Automatisation des bâtiments: Applied in power distribution protection for lighting, air conditioning and other systems in commercial buildings and industrial plants.
  12. Important Notes and Alternative Solutions
  13. Product Status

The 3VT8 series was officially discontinued in January 2024 and fully replaced by Siemensnew-generation 3VA/3VM/3VC series molded case circuit breakers. The 3VT8 series is no longer in production, with only limited spare parts support available.

  1. Modèles alternatifs recommandés (Based on 63A, Class H Breaking Capacity, 3-pôle, TMF Trip Unit)
Alternative SeriesModèle recommandéAvantages
3VA1 Series3VA1063-3ED36-0AA0Higher breaking capacity (25kA→36kA), more advanced tripping technology, richer accessory options
3VM Series3VM1063-1EA00-0AA0Cost-effective, suitable for basic power distribution applications, easy to install
3VC Series3VC1063-1AA00-0AA0Thermal-magnetic and electronic trip units optional, high intelligence level, supporting communication functions
  1. Precautions for Use
  2. Derating Operation: When the ambient temperature exceeds 40°C, the rated current must be derated according to the temperature coefficient.
  3. Correspondance des accessoires: Pay attention to matching the accessory with the circuit breaker model and pole number when selection, such as the voltage level of the shunt release.
  4. Spécifications d'installation: Ensure installation in a switchgear that meets requirements, with proper ventilation and heat dissipation maintained.
  5. Regular Maintenance: Periodically inspect the circuit breaker appearance, operating mechanism and trip unit performance to ensure reliable operation.
  6. Replacement Suggestion: For new projects, it is recommended to directly select 3VA/3VM/3VC series alternative products to achieve better performance and a longer service life.

Précédent:

Laisser une réponse

Laisser un message