Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

Siemens 3WL1N16-1600A ETU45B-G-LCD-3P - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

disjoncteur/

Siemens 3WL1N16-1600A ETU45B-G-LCD-3P

Model SeriesMéthode de montagePoids (kg)Remarques
3WL1116Fixed TypeÀ propos 45Including ETU45B trip unit
3WL1116Drawout TypeÀ propos 55Including drawer base and ETU45B trip unit
3WL1216Fixed TypeÀ propos 56Including ETU45B trip unit
3WL1216Drawout TypeÀ propos 65Including drawer base and ETU45B trip unit

  • Détails du produit

Siemens 3WL1N16-1600A ETU45B-G-LCD-3P is a low-voltage disjoncteur pneumatique manufactured by Siemens.

Type de produit: It belongs to the 3WL series air circuit breakers and can be used as incoming line, bus tie and feeder circuit breakers in electrical systems for industrial, building and infrastructure applications.

Interprétation du modèle: In the model 3WL1N16, “3” represents the product series code, “WL1indicates the No.1 specification of the 3WL series, “N” usually denotes the standard type, et “16” means the frame size current is 1600A; “1600UN” is the rated current of the circuit breaker; “ETU45Brefers to the model of the electronic trip unit; “G” signifies the ground fault protection function; “LCDmeans it is equipped with a liquid crystal display; “3P.” indicates that the circuit breaker is three-pole.

Caractéristiques techniques:

Comprehensive Protection Functions: It provides overload protection, protection contre les courts-circuits, ground fault protection and other functions. The overload protection L (long-time protection) of the electronic trip unit ETU45B allows switching characteristic curves between I²t and I⁴t, and the monitoring function I⁴t characteristic improves the selectivity with downstream circuit breakers and fuses.

Communication and Data Acquisition: It has communication capabilities and can transmit data such as current values, switch status and trip causes to the central computer via standard PROFIBUS DP or MODBUS. It can also cooperate with the Plus measurement function to realize energy data acquisition, facilitating remote monitoring and energy management.

High Adjustability: Protection functions can be set through rotary coding switches or slide switches, and parameters such as overload protection time-delay levels, and characteristic curves of overload and short-time delay short-circuit ranges can be adjusted according to actual requirements.

Display Function: Equipped with an LCD display, it can clearly show trip status, trip causes and other information, which is convenient for fault diagnosis and equipment maintenance.

Apparence et installation: Adopting a modular design, it is easy to maintain and modify. It can be installed by means of screw mounting or DIN rail mounting, and can be conveniently integrated into electrical systems.

Dimensions of Siemens 3WL1N16-1600A ETU45B-G-LCD-3P

> Note: The model “33WL1N16is likely a typo; the correct model should be 3WL1116 (Frame Size I) or 3WL1216 (Frame Size II) 1600A 3P ETU45B-G-LCD. In the correct model, “16” indicates a frame size current of 1600A, “3P.” means three-pole, et “ETU45B-G-LCDrepresents the electronic trip unit ETU45B with ground fault protection (G) and liquid crystal display (LCD).

  1. Core Dimension Parameters (Unit: mm)

1.1 Frame Size I (3WL1116 Series)

Méthode de montageLargeur (W)Height (H)Depth (D)Remarques
Fixed Type320434291Standard depth, excluding the protruding part of the operating mechanism
Drawout Type320434À propos 450Including the depth of the drawer base, subject to accessory configuration

1.2 Frame Size II (3WL1216 Series)

Méthode de montageLargeur (W)Height (H)Depth (D)Remarques
Fixed Type460434291Standard depth, excluding the protruding part of the operating mechanism
Drawout Type460434À propos 450Including the depth of the drawer base, subject to accessory configuration

1.3 Key Supplementary Instructions

  1. Height Consistency: The standard height of all 3WL series circuit breakers (Frame Size 0/I/II/III) is 434mm, which is the unified design standard of this series.
  2. Depth Difference:

The basic depth of the fixed type is 291mm (Frame Size I/II).

The depth of the drawout type increases by about 160mm (thickness of the drawer base).

If equipped with an extended operating mechanism or other special accessories, the depth may increase further.

  1. Impact of ETU45B-G-LCD: The type of electronic trip unit (ETU45B) and display mode (LCD) have no significant impact on the overall dimensions, and only affect the layout of the front panel of the circuit breaker.
  2. Mounting Hole Dimensions:

Frame Size I: Recommended mounting hole width is 310mm and height is 424mm.

Frame Size II: Recommended mounting hole width is 450mm and height is 424mm.

Mounting Spacing: It is recommended to reserve a heat dissipation space of ≥50mm between adjacent circuit breakers.

  1. Weight Reference
Model SeriesMéthode de montagePoids (kg)Remarques
3WL1116Fixed TypeÀ propos 45Including ETU45B trip unit
3WL1116Drawout TypeÀ propos 55Including drawer base and ETU45B trip unit
3WL1216Fixed TypeÀ propos 56Including ETU45B trip unit
3WL1216Drawout TypeÀ propos 65Including drawer base and ETU45B trip unit
  1. Dimension Selection Recommendations
  2. Frame Size Selection:

Frame Size I (3WL1116): Breaking capacity is 55kA, suitable for conventional industrial and building power distribution applications.

Frame Size II (3WL1216): Breaking capacity is 66/80/100kA, suitable for occasions with higher requirements for breaking capacity.

  1. Mounting Method Selection:

Fixed Type: Small space occupation and low cost, suitable for occasions where frequent maintenance is not required.

Drawout Type: Easy to maintain and replace, suitable for key circuits, but occupies more space.

Model Comparison Table of Siemens 3WL1N16-1600A ETU45B-G-LCD-3P with Other Brands

> Note: The model “33WL1N16is a typo; the correct model should be 3WL1116 (Frame Size I) or 3WL1216 (Frame Size II) 1600A 3P ETU45B-G-LCD.

  1. Model Clarification and Core Parameters
Élément de paramètreSpecification ValueDescription
Série de produitsSiemens SENTRON 3WLAir circuit breaker
Courant nominal1600UNFrame size current is 1600A
Numéro de pôle3P.Three-pole
Trip UnitETU45B-G-LCDElectronic trip unit with LSIG protection (Overload L, Short-circuit S, Instantaneous I, Ground fault G) and LCD display
Capacité de coupure3WL1116: 55/66leDifferent breaking capacities for Frame Size I/II
3WL1216: 80/100le
Méthode de montageFixed/DrawoutFacultatif
Tension nominale690V et50/60HZ
  1. Comparison of Corresponding Models and Parameters of Mainstream Brands
MarqueCorresponding ModelTaille du cadreCourant nominalTrip Unit TypeFonction de protectionCapacité de coupureMéthode de montageRemarques
Siemens3WL1116-3EG45-4GA4I/II1600UNETU45B-G-LCDLSIG (L: Long-time delay, S: Short-time delay, je: Instantané, G: Ground fault)je: 66leFixed/DrawoutOriginal model with communication and measurement functions
3WL1216-3EG45-4GA4II: 80le
ABBEmax2 E2N1600 R1600 PR121/P-LSIG-LCD-3PS21600UNPR121/P-LSIG-LCDLSIG, with energy management and fault recording65leFixed/DrawoutCompatible with PROFIBUS DP, measurement accuracy class 0.2
Schneider ÉlectriqueMasterpact MTZ2 16H2 Micrologic 5.0A-LCD-3P1600UN1600UNMicrologic 5.0A-LCDLSIG, with energy metering and event recording100leFixed/DrawoutNew generation MTZ2 series with higher breaking capacity
ChintNA1-2000X-1600M/3P LSIG-LCD2000UN1600UNM-type intelligent controller-LCDLSIG, with RS485 communication and harmonic analysis65leFixed/DrawoutCost-effective domestic alternative with abundant accessories
DélicieuxCDW3-2000N-1600M/3P LSIG-LCD2000UN1600UNMT-LSIG-LCDLSIG, with fault diagnosis and remote control60leFixed/DrawoutTechnical cooperation with Schneider Electric, stable performance
Changshu SwitchgearCW1-2000/1600A 3P LSIG-LCD2000UN1600UNIntelligent trip unit-LCDLSIG, with overvoltage/undervoltage protection65leFixed/DrawoutWell-known domestic brand with high cost performance
  1. Detailed Comparison and Analysis of Key Parameters

3.1 Protection Function Comparison

MarqueTrip Unit ModelProtection contre les surchargesShort-circuit ProtectionGround Fault ProtectionSpecial Functions
SiemensETU45BI²t/I⁴t selectable, adjustable from 0.4-1InShort-time delay 0.1-0.4s, instantaneous 2-10InAdjustable from 0.2-0.8InCommunication (PROFIBUS/MODBUS), energy data acquisition
ABBPR121/PInverse time/definite time selectableShort-time delay 0.05-0.5s, instantaneous 2-15InAdjustable from 0.1-0.5InPre-alarm function, fault location, maintenance reminder
Schneider ÉlectriqueMicrologic 5.0AThermal memory function, I²t characteristicShort-time delay 0.05-1s, instantaneous 2-15InAdjustable from 0.1-0.5InPower quality analysis, 100 event records
ChintM-typeInverse time characteristic, adjustable from 0.4-1InShort-time delay 0.1-0.4s, instantaneous 2-10InAdjustable from 0.2-0.8InHarmonic monitoring, remote control and parameter setting
DélicieuxMT-typeInverse time characteristic, adjustable from 0.4-1InShort-time delay 0.1-0.4s, instantaneous 2-10InAdjustable from 0.2-0.8InFault self-diagnosis, historical record inquiry

3.2 Mechanical and Electrical Life Comparison

MarqueDurée de vie mécaniqueDurée de vie électriqueFréquence de fonctionnement
Siemens150,000 opérations10,000 opérations (AC-3)300 opérations/heure
ABB150,000 opérations10,000 opérations (AC-3)300 opérations/heure
Schneider Électrique150,000 opérations10,000 opérations (AC-3)300 opérations/heure
Chint100,000 opérations8,000 opérations (AC-3)200 opérations/heure
Délicieux100,000 opérations8,000 opérations (AC-3)200 opérations/heure

3.3 Dimension and Installation Compatibility Comparison

MarqueLargeur (mm)Height (mm)Depth (mm)Méthode de montageCompatibilité
Siemens 3WL1116320434291 (Fixé) / 450 (Drawout)35mm rail DIN / Screw mountingCompatible with 3WA series
ABB Emax2320430285 (Fixé) / 445 (Drawout)Screw mountingCompatible with Emax series
Schneider Electric MTZ2320430290 (Fixé) / 455 (Drawout)Screw mountingCompatible with MT series
Chint NA1320430290 (Fixé) / 450 (Drawout)Screw mountingCompatible with NA1 series
Delixi CDW3320430290 (Fixé) / 450 (Drawout)Screw mountingCompatible with CDW3 series
  1. Alternative Selection Recommendations
  2. Original Replacement: The Siemens 3WL series has been gradually upgraded to the 3WA series (par ex., 3WA1116-3EG45-4GA4), which maintains the same installation dimensions and protection functions with higher intelligence.
  3. Brand Replacement Priority:

High-end industrial applications: Priority should be given to ABB Emax2 or Schneider Electric MTZ2, which have better breaking capacity and communication functions.

Buildings and infrastructure: Choose Chint NA1 or Delixi CDW3 for high cost performance and low maintenance costs.

Projects with limited budgets: Choose Changshu Switchgear CW1 for stable performance and affordable price.

  1. Key Selection Notes:

Ensure that the breaking capacity ≥ the maximum short-circuit current of the system (un 20% margin is recommended).

The protection function of the trip unit matches the load type (LSIG is required for motor loads, and LSI is optional for distribution loads).

The installation dimensions match the existing cabinet space to avoid cabinet modification.

The communication protocol is compatible with the monitoring system (PROFIBUS/MODBUS/Ethernet).

  1. Résumé

Siemens 3WL1116/3WL1216 1600A ETU45B-G-LCD-3P is a mature and reliable air circuit breaker, and all mainstream brands have alternative models with equivalent performance. During selection, comprehensive consideration should be given to application scenarios, budgets and system requirements to ensure that the protection functions, breaking capacity and installation compatibility meet the needs.

Précédent:

Suivant:

Laisser une réponse

Laisser un message