LUST CM-DPV1.3.0 Detailed Specifications

LUST‑CM‑DPV1.3.0: Modulo di comunicazione LUST Profibus-DP

LUST‑CM‑DPV1.3.0: Modulo di comunicazione LUST Profibus-DP

(PROFIBUS-DP Communication Module)

CM-DPV1.3.0 is a PROFIBUS-DPV1 communication module designed by LUST (later acquired by Lenze) specifically for C-line series drives. Below are the complete technical specifications and functional features.

  1. Basic Information

Modello: CM-DPV1.3.0 (also marked as CM-DPV1,3.0)

Tipo di prodotto: PROFIBUS-DP Slave Communication Module (supports DPV1 extension protocol)

Applicable Drives: CDA3000 Inverter, CDD3000 Servo Controller, CDE/CDB3000 Position Controller, CTC3000 Direct Drive Controller

Software Version: Commonly V2.25-00 (upgradable via DriveTop)

Modello sostitutivo: CM-DPV1.3.1 (hardware compatible, software optimized)

Lenze Replacement: EMF2177IB (fully functionally compatible)

  1. Electrical Specifications
ArticoloSpecifica
Supply Voltage18–30 V DC (powered by drive backplane)
Massimo. Operating Current0.25 UN
Interfaccia di comunicazionePROFIBUS-DP (9‑pin D‑sub, conforme alla norma EN 50170)
Baud Rate9.6 kbps / 19.2 kbps / 45.45 kbps / 93.75 kbps / 187.5 kbps / 500 kbps / 1.5 Mbps / 3 Mbps / 6 Mbps / 12 Mbps (auto‑detection)
Slave Address Range1–125 (set by DIP switches S1/S2 or parameter 582‑PBADR)
Process Data (PZD)Input: max. 244 bytes; Output: max. 244 bytes
Acyclic Data (PKW/DPV1)Supports parameter read/write, diagnostics, firmware upload
Classe di protezioneIP20 (installed inside the drive)
Operating Temperature0–55 °C
Storage Temperature-25–+70 °C
DimensioniApprox. 90 × 90 × 30 mm (for C-line communication slot)
PesoApprox. 0.16 kg
  1. Functions and Protocol Features
  2. DPV1 Protocol Support

Cyclic data exchange (PZD): real-time control word, setpoint, status word, actual value

Acyclic data exchange (PKW): parameter read/write, diagnostics, firmware update

Extended diagnostics: detailed network/module/drive status, fault codes

  1. Data Structure

EasyDrive Mode: standard PZD structure (control word / status word + setpoint / actual value)

ProfiDrive Mode: compliant with PROFIdrive profile, suitable for standard PLC configuration

  1. Diagnostic Functions

Bus status, module status, communication errors, drive faults

Supports PROFIBUS standard diagnostic messages and extended diagnostics

  1. Configuration Methods

Hardware: address setting via DIP switches, X13 interface coding

Software: parameter configuration via LUST DriveTop / Lenze Engineer, GSD file configuration

GSD File: LUST08E9.GSD (standard version)

  1. Installation and Compatibility

Posizione di installazione: Dedicated communication slot for C-line drives (no extra wiring needed)

Compatibilità: Hardware compatible with CM-DPV1.3.1, direct replacement

Configuration Tools: DriveTop (LUST), Engineer (Lenze)

Sistemi supportati: Mainstream PROFIBUS masters such as Siemens, Schneider, ABB

  1. Applicazioni tipiche

Automated production lines, robot systems, macchine per l'imballaggio, printing equipment, material handling

Industrial automation systems requiring PROFIBUS-DP centralized control, parameterization and diagnostics