CJX2-3210 is a 3-pole 32A AC contactor from CHINT CJX2 series, con 3 NO main poles + 1 NO auxiliary contact. It is suitable for controlling 15kW motors at AC-3 380V. Coil voltages include 220V/380V and others. Direct replacement models include Schneider LC1N3210, Siemens 3RT6035-1AN20, ecc. Model Explanation & Basic Positioning Model Part Meaning CJX2 ...

  • Dettagli del prodotto

CJX2-3210 is a 3-pole 32A Contattore CA from CHINT CJX2 series, con 3 NO main poles + 1 NO auxiliary contact.

It is suitable for controlling 15kW motors at AC-3 380V. Coil voltages include 220V/380V and others.

Direct replacement models include Schneider LC1N3210, Siemens 3RT6035-1AN20, ecc.

  1. Model Explanation & Basic Positioning
Model PartSenso
CJX2CHINT AC contactor series (equivalent to Schneider LC1‑D series)
32Rated operational current 32A (AC‑3 utilization category at 400V)
10Contatti ausiliari: 1 NO + 0 NC

Posizionamento del prodotto:

Industrial‑grade general‑purpose AC contactor, suitable for frequent starting and control of AC motors.

Can form a magnetic starter with thermal overload relays for motor protection.

  1. Parametri tecnici chiave
ArticoloSpecifica
Rated operational voltageUp to 690V AC (50/60Hz)
Corrente operativa nominale32UN (AC‑3 400V), thermal current Ith = 50A
Controlled power15kW (AC‑3 380V), 21UN (AC‑3 660V)
Auxiliary contact1 NO, rated 5A/220V AC
Tensione della bobinaOpzionale: 220V/380V/110V/36V/24V AC
Insulation characteristicsUI = 660V, compliant with GB14048.4 / IEC60947‑4‑1
Mechanical / electrical life10 milioni di volte / 1 milioni di volte (AC‑3)
Dimensioni (L×W×H)83×58×101 mm
MontaggioStandard 35mm DIN rail
  1. Caratteristiche strutturali & Materiali
  2. Silver alloy contacts: Excellent conductivity and arc resistance, ensuring reliable switching.
  3. 32‑sheet silicon steel core: Reduces hysteresis loss, smoother pull‑in, stable operation.
  4. Flame‑retardant housing: Meets V0 flame rating, improves safety.
  5. Clear side marking: Modello, voltaggio, Certificazione CCC, ecc.
  6. Applicazioni
  7. Industrial automation: Motor control, tifosi, pumps, compressori.
  8. Building electrical: HVAC, fire pumps, exhaust fans.
  9. Agricultural machinery: Irrigation, feed processing equipment.
  10. Power systems: Remote circuit control in distribution panels.
  11. Typical matching: Long‑running oil station motors, unidirectional equipment (no NC auxiliary required).
  12. Comparison Within CJX2 Series
ModelloCorrente nominaleAux. ContactsAC‑3 380V PowerDimensioni (mm)
CJX2‑09109UN1 NO4kW73×47×82
CJX2‑181018UN1 NO7.5kW73×47×82
CJX2‑251025UN1 NO11kW83×58×96
CJX2‑321032UN1 NO15kW83×58×101
CJX2‑401140UN1 NO + 1 NC18.5kW128×79×116
CJX2‑651165UN1 NO + 1 NC30kW128×79×116
  1. Cross‑Brand Replacements
MarcaModello sostitutivoCompatibilità
SchneiderLC1N3210M7N / LC1R3210M5NStesse dimensioni & parameters
Siemens3RT6035‑1AN20 (domestic type)Functionally equivalent, mounting compatible
ABBA145‑30‑11 (32A class)Aux. can be configured as 1 NO
DeliziosoCJX2‑3210Fully interchangeable
Interruttore ChangshuCK3‑3210Same performance & parameters
  1. Selection & Application Notes
  2. Tensione della bobina: Selected per control circuit (commonly 220V / 380V).
  3. Load matching: 32A ≈ 15kW at AC‑3 380V; avoid overload.
  4. Aux. contact expansion: F4‑11 or similar modules can be added.
  5. Protection coordination: Used with NR2 series thermal relays (e.g. NR2‑36) for overload protection.
  6. Ambiente: Operating temperature ‑5°C ~ +40°C; avoid dust & corrosive gas.

Packing: 4 pcs/box, 32 pcs/carton

Comparison of CHINT Contactor Series

Overview:

CHINT contactors are divided into:

Classic (CJX2/CJ20/CJX8), Upgraded (NXC/NC5), High‑Power (NC8), DC Special (CJZ8/NCZ5).

NXC fully replaces CJX2 with better performance; NC5 focuses on intelligence & modularity; NC8 covers ultra‑high current; CJZ8 is for DC control.

Priority: NXC / NC5; use special series for special applications.

  1. Series Positioning & Replacement
SeriePositioningReplaced By / ReplacesCaratteristiche principali
CJX2Classic generalFully replaced by NXCCost‑effective, simple structure, flexible aux. contatti
NXCNew generationReplaces CJX2, upgradedHigh efficiency, long life, standard 1NO+1NC, strong modularity
NC5Smart & premiumHigh‑end marketWide temp ‑25°C~+55°C, communication, complex automation
NC8High‑power heavy‑dutyIndependent, up to 1000AUp to 1000A AC‑3 415V, for large motors & heavy industry
CJX8Traditional heavy‑dutyPartially replaced by NC8Direct‑operated double break, suitable for legacy retrofits
CJ20Traditional generalReplaced by NXC/NC5Mature structure, basso costo, civil & light industry
NXC‑XMGSpecial loadIndependentFor fans & pumps, high energy saving
CJZ8/NCZ5DC dedicatedIndependentEnhanced arc extinguishing, new energy & energy storage
  1. Parametri tecnici chiave

2.1 Basic Electrical Data

SerieCurrent RangeTensione nominaleAC‑3 380V PowerStandard Aux. Contacts
CJX29A~95AUp to 690V0.75kW~45kWBelow 32A: 1NO/1NC; ≥40A:1NA+1NC
NXC6A~630AUp to 690V0.37kW~315kWFull range: 1NA+1NC
NC56A~630AUp to 690V0.37kW~315kW1NA+1NC, expandable to 6NO+6NC
NC86A~1000AUp to 690V0.37kW~500kW2NO+2NC, expandable to 6NO+6NC
CJX89A~250AUp to 660V4kW~110kW3NO+1NO/1NC or 4NO
CJ2010A~630AUp to 660V5.5kW~315kW1NA+1NC

2.2 Life & Ambiente

SerieVita meccanicaVita elettrica (AC‑3)Operating TempMontaggio
CJX210 million1 million‑5°C~+40°C35mm DIN / screw
NXC12 million1.2 million‑25°C~+55°C35mm DIN / screw
NC515 million1.5 million‑25°C~+55°C35mm DIN / screw
NC810 million0.8 million (high current)‑25°C~+55°CMainly screw
CJ208 million0.8 million‑5°C~+40°CScrew
  1. Structure & Functional Differences

3.1 CJX2 (Classic)

Structure: Direct‑operated single break, modular; F4 aux., F5 timer, NCF1 side aux. available.

Contacts: Silver alloy, 3P main, flexible aux. (10/01/11).

Bobina: CA/CC, 24V~380V.

3.2 NXC (Upgraded)

Optimized magnetic system, coil power ≈ 30% lower than CJX2.

Improved silver alloy contacts, better arc extinguishing.

Standard 1NO+1NC; supports aux., timer, interblocco meccanico.

3.3 NC5 (Smart Premium)

Optional communication module (ModBus, ecc.) for IIoT.

Wide temperature, suitable for outdoor & harsh environments.

Enhanced insulation & short‑circuit withstand.

3.4 NC8 (High‑Power)

Enhanced arc chamber for high‑current breaking up to 1000A.

Optimized heat dissipation for heavy‑duty continuous operation.

Heavy‑duty mechanical structure, high vibration resistance.

3.5 CJX8 (Traditional Heavy‑Duty)

Direct‑operated double break; front‑connected or rear‑connected versions.

Fino a 4 poli (3 main + 1 aux or 4 main) for special applications.

3.6 DC Contactors

CJZ8: Low‑voltage DC (12V~220V), up to 40A, small DC loads.

NCZ5: High‑voltage DC (up to 1500V), up to 500A, new energy vehicles & energy storage.

Dedicated DC arc extinguishing structure.

  1. Scenari applicativi
SerieBest ForTypical LoadNot Recommended
CJX2Legacy retrofit, budget projectsSmall motors ≤15kW, illuminazione, heatingHigh‑end automation, harsh environments
NXCIndustrial automation, new projectsMedium motors ≤315kW, tifosi, pumpsUltra‑large motors, special DC loads
NC5Smart factories, complex systems, outdoorMedio & large motors, production linesCost‑sensitive simple circuits
NC8Large industry, power, metallurgiaLarge motors ≤500kW, trasformatoriSmall loads, civil buildings
CJX8Legacy maintenance, special controlTraditional machinery, special circuitsNew smart projects
CJ20Civil, light industry, temporary powerAC units, pumps, small machinesFrequent switching, high‑end automation
DC seriesNew energy, energy storage, railDC motors, batteries, chargersAC loads
  1. Selection Guide & Replacements

5.1 Selection Priority

  1. New projects: NXC (replaces CJX2)
  2. Smart/complex systems: NC5
  3. Ultra‑high power >315kW: NC8
  4. DC loads: CJZ8 / NCZ5
  5. Legacy retrofit: CJX2/CJ20/CJX8 or upgrade to NXC/NC5

5.2 Cross‑Series Replacement

OriginalRecommended ReplacementAdvantage
CJX2‑09~95NXC‑06~100Standard 1NO+1NC, life +20%, power ‑30%
CJ20‑10~630NXC‑12~630 / NC8‑12~1000Better performance, modular, easier maintenance
CJX8‑09~250NC8‑06~250Better arc extinguishing, wide temperature

5.3 Model Selection Tips

Current: 32A ≈ 15kW; 63A ≈ 30kW; 100A ≈ 45kW at AC‑3 380V.

Aux. contatti: NXC has 1NO+1NC standard; CJX2 uses 10/01/11.

Bobina: 220V/380V/110V/36V/24V AC/DC.

Montaggio: 35mm DIN preferred; screw for high power.

  1. Special Notes: CHINT CJX2‑3210

As a representative model of CJX2 series, CJX2‑3210 is a 3‑pole 32A AC contactor with 3 NESSUN contatto principale + 1 NO auxiliary contact, suitable for 15kW motor control at AC‑3 380V.

Common replacements:

CHINT NXC‑3210 (upgraded)

Schneider LC1N3210M7N

Siemens 3RT6035‑1AN20

ABB A145‑30‑11 (32A class)

Prec:

Lascia una risposta

Lasciate un messaggio