The Chint DT862-4 three-phase four-wire electric meter is a classic mechanical electric energy meter, specifically designed for industrial and commercial scenarios, and is suitable for the active electric energy metering of three-phase four-wire circuit. The following are its core information and application guidelines: Core Functions and Technical Parameters Metering Characteristics Measuring Range: It supports direct connection type ...

  • Dettagli del prodotto

The Chint DT862-4 three-phase four-wire electric meter is a classic mechanical electric energy meter, specifically designed for industrial and commercial scenarios, and is suitable for the active electric energy metering of three-phase four-wire circuit. The following are its core information and application guidelines:

  1. Core Functions and Technical Parameters
  2. Metering Characteristics

Measuring Range: It supports direct connection type (ad esempio 10(40)UN, 15(60)UN) and mutual inductance type (ad esempio 1.5(6)UN), covering the load requirements of small and medium power.

Accuracy Class: Class 2, meeting the GB/T 15283-1994 standard, with an error range of ±2%.

Voltage Specification: 3×220/380V (line voltage 380V, phase voltage 220V), suitable for industrial power supply environments.

Frequency Range: 50Hz, in line with the domestic power grid standard.

  1. Structural Design

Material: The shell is made of cold-rolled steel plate, with an IP30 protection level, dustproof and splash-proof.

Dimensioni: The external dimensions of the standard model are 279.5×172×124mm, and the installation hole spacing is 140×106mm, which is suitable for common power distribution cabinets.

Display: Mechanical counter, with the integer part displayed in a black frame and the decimal part displayed in a red frame, which is intuitive and easy to read.

  1. Adattabilità ambientale

Operating Temperature: -10°C to +50°C (some models support -25°C to +55°C), adapting to different climatic conditions.

Humidity: Relative humidity ≤ 85%. Avoid long-term use in high humidity environments.

  1. Application Scenarios and Installation Key Points
  2. Applicazioni tipiche

Distribuzione dell'energia industriale: In scenarios where three-phase loads are concentrated, such as factories and workshops, to measure the total electricity consumption.

Commercial Buildings: In places that require phase-by-phase metering, such as shopping malls and office buildings.

Agricultural Irrigation: Suitable for equipment such as water pumps driven by three-phase motors.

  1. Wiring Methods

Direct Connection Type: Suitable for circuits with a current ≤ 100A. The incoming live wires are connected to holes 1, 3, E 5, the outgoing wires are connected to holes 2, 4, E 6, and holes 7 E 8 are connected to the neutral wire.

Mutual Inductance Type: It needs to be matched with a current transformer (such as 200/5A). The incoming live wires are connected to holes 1, 3, E 5. The S1 of the secondary side of the current transformer is connected to holes 2, 4, E 6, the S2 is short-circuited and then grounded, and holes 7 E 8 are connected to the neutral wire.

Note:

The transformation ratio of the current transformer needs to match the specification of the electric meter (Per esempio, UN 1.5(6)A electric meter is matched with a 100/5A current transformer).

Copper wires with a cross-sectional area ≥ 2.5mm² should be used for wiring to ensure reliable contact.

  1. Specifiche di installazione

Vertical Installation: The electric meter needs to be vertically fixed, and the inclination ≤ 1° to avoid affecting the metering accuracy.

Spacing Requirements: Maintain a spacing of more than 50mm from other electrical components for easy heat dissipation and maintenance.

III. Purchase and After-sales Service

  1. Prezzo di riferimento
  2. Suppliers in Hebei Region

Hebei China Electric

  1. After-sales Service

Warranty Period: Usually 1 year, and some channels provide a 3-month warranty.

Gestione dei guasti: In case of abnormal counting or a stuck dial, you can contact Chint, or submit an after-sales application through the official website.

  1. Alternative Solutions and Extended Functions
  2. Smart Upgrade Options

Electronic Electric Meter: Per esempio, the DDSY666 type supports prepayment, RS485 communication, and remote meter reading, which is suitable for users who need intelligent management.

Multifunctional Electric Meter: The DT862-4K model integrates functions such as time-of-use billing and load recording, and supports the Modbus protocol.

  1. Adaptation to Special Requirements

Outdoor Environment: Select the DT862-4 outdoor type with an IP54 protection level, which needs to be customized in advance.

High-precision Metering: If a Class 1 accuracy is required, the DS862-4 model (380V 1.5(6)UN) can be considered.

  1. Risk Control and Compliance
  2. Qualification Verification

Certificazione: Require the supplier to provide a 3C certification and a type test report to ensure that the product meets the GB7251.1 standard.

Brand Anti-counterfeiting: The genuine electric meter shell is printed with a laser anti-counterfeiting label, and the serial number can be queried through Chint’s official website.

  1. Contract Terms

Acceptance Standard: Clearly specify that it should be calibrated according to the JJG307-2006 regulation, and the error should be ≤ ±2%.

Transportation Insurance: It is recommended to purchase the wooden box packaging service, and the supplier shall bear the damage during transportation.

  1. Typical Case

In the transformation of a factory’s power distribution system, a DT862-4 15(60)A direct connection type electric meter was adopted, matched with a Schneider NSX circuit breaker, to achieve real-time metering of three-phase loads. Purchased through a local distributor in Hebei, the total cost was reduced by 15% compared with direct purchase from the original factory. Dopo l'installazione, it was detected by a third party, and the error rate was +1.2%, which meets the national standard.

If you need further assistance in model selection or obtaining technical documents, you can provide specific current specifications, installation environments and other information, and I will continue to provide support for you.