Nome completo del prodotto: MFH-3-1/4-S, Ordine n.7959, Tiger Classic Series 3/2-way Normally Closed Single Solenoid Elettrovalvola
⚠️ Valve body does NOT include solenoid coil; coil must be ordered separately
✅ Key Specifications
| Articolo | Parametro |
| Funzione della valvola | 3/2-modo, normalmente chiuso, single stable, ritorno primaverile |
| Porti | Main ports: G1/4; Pilot port 12 & pilot exhaust port 82: M5 |
| Nominal Flow Rate | 800 l/min |
| Diametro nominale | 7 mm |
| Pressione operativa | -0.95 ~ 10 sbarra (vacuum ~1.0 MPa) |
| Pilot Pressure | 1 ~ 8 sbarra (external pilot supply) |
| Switching Time | 10 SM (energize) / 29 SM (de-energize) |
| Classe di protezione | IP65 (with matched coil) |
| Alloggiamento | Alluminio pressofuso; Seal: NBR nitrile rubber |
| Peso | 320 G |
| Temperatura ambiente | -5 ~ +40℃; Temperatura media -10 ~ +60℃ |
| Medio | Compressed air ISO 8573-1:2010 [7:4:4], oil lubrication permitted |
| Sostituzione manuale | Detenting manual pushbutton |
| Montaggio | Montaggio su guida / through-hole mounting, any mounting orientation |
| Certificazioni | c UL us Recognized, RoHS |
📌 Model Code Explanation
MFH: Tiger Classic series solenoid valve
3: 3/2-valvola a vie
1/4: Main port thread G1/4
S: External pilot supply version
🛠️ Application Scenarios
Single-acting cylinder control, vacuum circuit, air blow-off/shutoff, macchine per l'imballaggio, machine tool pneumatic circuits, air switches for automated production lines.
External pilot: Cannot be driven directly by low-pressure vacuum. Pilot supply must be independently supplied with ≥1bar control air.
🔁 Same Series Reference (Ordine n.)
7958: MFH-3-1/8-S (G1/8)
7959: MFH-3-1/4-S (G1/4)
7960: MFH-3-1/2-S (G1/2)
⚠️ Selection & Note sulla manutenzione
- Solenoid coil must be purchased separately (per esempio. MSFW series, AC220V / DC24V). Valve body comes without coil;
- External pilot structure, independent pilot air supply, works reliably even when main circuit is under negative pressure;
- Poppet valve design with soft seal: excellent sealing performance, but vulnerable to wear if medium contains heavy dust;
- Second-hand inspection focus: manual button operation, air tightness test (pressurize port 1: no output at port 2 when de-energized, air output at port 2 when energized).
FESTA 7959 (MFH-3-1/4-S) Casi di applicazione
Core advantage: External pilot 3/2-way normally closed poppet valve, compatible with vacuum in main circuit, high flow rate 800L/min; independent pilot air supply via M5 port ≥1bar. This is the biggest difference from standard internal-pilot MFH valves.
Caso 1: Packaging Machine|Single-acting Clamping Cylinder Control (Più comune)
Attrezzatura: Horizontal form-fill-seal machine, vertical bagging machine, carton folding machine
Circuito: 7959 → Single-acting spring return clamping cylinder
Bobina eccitata: Valve shifts, compressed air enters cylinder cap end, workpiece clamped;
Bobina diseccitata: Valve resets, cylinder chamber exhausts, spring releases workpiece.
Motivi della selezione
- G1/4 high flow, fast clamping response; detent manual button allows manual clamping test during commissioning;
- Soft seal poppet valve, low leakage after long frequent cycling;
- PAL rail manifold mountable, multiple valves mounted side-by-side for centralized air supply and exhaust.
Nota: Pilot air shall be taken from a separate clean air source, not shared with main cylinder air supply.
Caso 2: Pick a vuoto & Place Circuit (Representative Application of This Valve)
Attrezzatura: PCB mounter, carton feeding manipulator, plastic part handling suction cup module
Circuito: Vacuum generator → 7959 valve → Vacuum suction cup
Diseccitato: Valve closed, suction cup disconnected from vacuum source, suction cup vented to atmosphere, pezzo rilasciato;
Eccitato: Valve opens, vacuum connected to suction cup, workpiece picked up.
✅ Key point: External pilot version allows vacuum in main circuit. Internal-pilot MFH cannot be directly used for vacuum circuits (negative pressure in main circuit causes unreliable shifting). This is the core value of 7959 (suffix -S).
Nota: M5 pilot port must be continuously supplied with ≥1bar clean compressed air. Vacuum cannot be used as pilot supply.
Caso 3: Machine Tool|Chip Blow-off & Workpiece Ejection
Attrezzatura: Tornio CNC, machining center, stamping machine workpiece blow-off, material bin air separation
Circuito: Main air supply G1/4 → 7959 → Air nozzle
Eccitato: High-flow air jet blows away metal chips or eject finished workpieces out of station;
Diseccitato: Air supply cut off, nozzle pressure relieved.
Motivi della selezione: 800L/min high flow for high intensity short pulse blowing; poppet valve tolerates minor dust for machine tool cutting environment; IP65 allows mounting outside machine cabinet.
Caso 4: Gomma & Plastics Industry|Single-acting Lifting/Ejection Mechanism
Attrezzatura: Injection molding machine mold ejection, rubber molding machine demolding, hot pressing tool lifting
Circuito: 7959 driving large bore single-acting spring return cylinder for mold ejection.
Caratteristiche: Die-cast aluminum housing tolerates oil contamination and elevated temperature in mold environment; valves can be assembled on manifold rail;
Safety merit: Automatic spring reset upon power loss, mold retracts automatically for safety redundancy.
Caso 5: Conveyor Line|Pilot Control for Pneumatic Valves (Used as Pilot Valve)
Attrezzatura: Sorting conveyor, pallet stopper, large bore pneumatic shut-off valve
Circuito: PLC drives 7959; 7959 outputs pneumatic signal to actuate large-size main pneumatic valve.
Scenario: Main valve has huge flow capacity and cannot be directly driven by small solenoid valves; 7959 serves as secondary pilot valve to provide control air signal.
Vantaggi: 10ms risposta rapida, stable pilot output, suitable for 2-stage control of large pneumatic circuits.
Caso 6: Modifica & Replacement for Legacy Equipment (Spare Part Application)
Many imported automated production lines manufactured from 1990s to 2010 adopt Tiger Classic poppet valves. Damaged MFH-3-1/4-S (7959) può essere sostituito direttamente.
Industry status: This classic legacy spare part. Specified on drawings of many packaging, macchine da stampa e tessili. Supports through-hole mounting or PAL rail mounting; no hole modification required during replacement.
Common Risk Reminders Across All Cases
- Valve body without coil, MSFW coil must be ordered separately (DC24V most popular);
- -S = external pilot, M5 pilot port pressure ≥1bar, pilot air filtration ≥40μm; insufficient pilot pressure causes no shifting or intermittent misfiring;
- Medium must be filtered; dust particles scratch poppet seal and cause internal leakage;
- In vacuum applications, main circuit negative pressure cannot be used for pilot supply; independent positive pressure air source required for pilot.
Industry Summary List
Macchine per l'imballaggio: Carton machine, horizontal packaging machine, heat sealer (bloccaggio, vacuum material pick-up)
Macchina utensile & Lavorazione dei metalli: Chip blow-off, workpiece ejection
Gomma & Plastics Injection: Mold single-acting ejection
Automazione della logistica: Suction cup handling, sorting stopper
Stampa & Tessile: Fabric clamping, paper stack air separation
Legacy imported equipment maintenance & sostituzione (Tiger Classic valve)
Working Principle of MFH-3-1/4-S (Festa 7959)
Model breakdown: 3/2-modo, normalmente chiuso, single-solenoid spring return, external pilot (-S) poppet solenoid valve
Importante: This is an external pilot valve. The solenoid coil only controls pilot air and does NOT directly actuate the main spool, completely different from direct-acting solenoid valves.
- Definizione del porto (3/2-way Valve)
Porta 1: Main air supply inlet (G1/4)
Porta 2: Working output port → Connect to cylinder / suction cup / ugello
Porta 3: Porta di scarico (main circuit exhaust)
Porta 12: Pilot supply port M5 (external pilot dedicated, must be supplied ≥1bar clean compressed air)
Porta 82: Pilot exhaust port M5
Definition of 3/2-way: 3 porti aerei, 2 working states (de-energized / energizzato)
- Two Operating States
✅ State 1: Coil De-energized (Home Position, Normalmente chiuso)
- Main poppet is pressed against main valve seat by return spring force;
- Circuito principale: Port1 (main supply) ↔ Port2 disconnected; Port2 ↔ Port3 (scarico) connected;
- Pilot circuit: Pilot control chamber exhausted via port82, no pressure inside pilot chamber;
- Risultato:
For single-acting cylinder: Cylinder exhausts and retracts by spring;
For vacuum suction cup: Suction cup vented to atmosphere, pezzo rilasciato.
✅ State 2: Coil Energized (Shifted Position)
- Solenoid coil pulls armature → opens small internal pilot slide valve;
- Compressed air from external pilot supply (port12) enters control chamber of main poppet;
- Pressure from pilot air generates thrust to overcome return spring and shift main poppet;
- Main circuit switching: Port1 ↔ Port2 connected; Port2 ↔ Port3 exhaust port blocked;
- Risultato:
Compressed air flows from port1 to port2 to actuate actuators;
Vacuum circuit: Port2 connected to vacuum source, negative pressure generated at suction cup for workpiece pick-up.
After de-energization, pressure inside control chamber discharges through port82 pilot exhaust port, spring pushes main poppet back to home position, returning to normally closed state.
- Caratteristica principale: Principle of External Pilot (-S) (Chiave)
Internal pilot valve: Pilot air is tapped from main supply port 1. If main circuit is under vacuum (negative pressure), no positive pressure available at port1 to generate thrust to shift poppet, cannot be used for vacuum circuits.
External pilot (-S): Pilot air is independently supplied from port12, fully isolated from main circuit (port1/2/3).
Main circuit port1 can carry compressed air or vacuum negative pressure. As long as port12 pilot supply maintains ≥1bar positive pressure, reliable valve shifting is guaranteed.
👉 This is the fundamental reason why 7959 can be used in vacuum suction cup circuits.
- Structure Overview (Poppet Valve)
It is a poppet valve, not slide valve: Sealing is achieved by pressing rubber seal against valve seat.
Vantaggi: Excellent sealing performance, low leakage;
Svantaggi: Sensitive to dust in medium; solid particles may scratch sealing surface and cause internal leakage.
- Manual Override Mechanism
The valve body is equipped with detenting manual pushbutton:
Press and rotate to lock, mechanically actuate pilot spool. Manual shifting available without power or coil energization, used for commissioning, air test and maintenance.
- Concise Principle Comparison Table
| Articolo | MFH-3-1/4-S (7959 External Pilot) | Standard Internal-pilot MFH Valve |
| Pilot Air Source | Independent supply via M5 port12 | Tapped from main supply port1 |
| Main Circuit Medium | Aria compressa / vacuum available | Compressed air only (positive pressure) |
| Vacuum Circuit Application | ✅Supportato | ❌ Non supportato |
| Pilot Pressure Requirement | 1~8bar | Depends on main supply pressure |