Model Segment Definition
| Segmento modello | Senso | Descrizione |
| RS20 | Product series identifier | Hirschmann RS20 series compact open DIN-rail industrial Ethernet switch, design senza ventola, suitable for industrial automation environments |
| 1600 | Port quantity | 16 = total 16 porti; 00 = base model code |
| S2 | Uplink Port 1 tipo | S = Single-mode fiber (SM); 2 = SC interface, 100BASE-FX speed |
| T1 | Uplink Port 2 tipo | T = Twisted Pair (TP); 1 = RJ45 interface, 10/100BASE-TX speed |
| SDA | Port configuration | S = Standard port; D = 14 RJ45 data ports; A = Auto-negotiation / Auto MDI-X function |
| U | Software version | U = Unmanaged; plug-and-play, nessuna configurazione richiesta |
| HC | Grado di temperatura & certificazione | H = Wide temperature range (-40~+70℃); C = Compliant with industrial standards IEC 61850-3, UL 508, ISA 12.12.01, ecc. |
- Core Specification Table
Parametri di base
| Articolo | Specifica |
| Manufacturer | Belden Hirschmann |
| Parte n. | RS20-1600S2T1SDAUHC (Ordine n.: 943 434-051) |
| Tipo di prodotto | 16-port unmanaged industrial Ethernet switch |
| Modalità di commutazione | Store-and-Forward |
| Montaggio | Standard NS 35/7.5 Montaggio su guida DIN |
| Dimensioni | W130mm × H90mm × D60mm |
| Peso | ca. 650G |
| Materiale dell'alloggiamento | Metallo, Classe di protezione IP20 |
| Raffreddamento | Senza ventola, natural heat dissipation |
Configurazione della porta
| Articolo | Specifica |
| Total Ports | 16 |
| Data Ports | 14 × 10/100BASE-TX RJ45, support auto-negotiation / auto MDI-X |
| Uplink Port 1 | 1 × 100BASE-FX single-mode fiber SC port, transmission distance up to 15km |
| Uplink Port 2 | 1 × 10/100BASE-TX RJ45, support auto-negotiation / auto MDI-X |
| Port Features | Full-duplex / Half-duplex support, 802.3x flow control |
| Cable Type | Twisted pair: Cat.5e and above, max 100m; Single-mode fiber: 9/125µm |
Caratteristiche Elettriche
| Articolo | Specifica |
| Ingresso alimentazione | Wide voltage: 12-48VCC, 24VCA(±10%) |
| Power Interface | 1 × 6-pin pluggable terminal block, supports dual power redundancy |
| Consumo energetico | Max 15W |
| Protezione contro le sovratensioni | Conforme alla norma CEI 61000-4-5, differenziale / common mode protection |
| EMC | IN 55032 Class A, IN 55035, IN 61000-6-2 |
Meccanico & Caratteristiche ambientali
| Articolo | Specifica |
| Temperatura operativa | -40~+70℃ (Wide temperature model) |
| Temperatura di conservazione | -40~+85℃ |
| Umidità | 5~95%RH (Non-condensing) |
| Resistenza alle vibrazioni | 5-150Hz, 1G (CEI 60068-2-6) |
| Resistenza agli urti | 15G (11SM) (CEI 60068-2-27) |
| Certificazioni | CE, cUL508, ISA 12.12.01, Classe 1 Div 2, CEI 61850-3 |
- Elenco degli accessori
Accessori standard
- RS20-1600S2T1SDAUHC switch main unit
- Pre-installed DIN rail mounting clips
- Pre-installed 6-pin power terminal block
- User manual (hard copy / electronic version)
- Product certification documents
Accessori opzionali
| Nome dell'accessorio | Modello | Descrizione della funzione |
| Redundant Power Module | RPS-24DC | Provides dual redundant power input to improve system reliability |
| Fiber Patch Cord | SC-SC Single-mode 9/125μm | Fiber connection for Uplink Port 1 |
| Cavo di alimentazione | 12-48VCC | Matches switch power input |
| Marker Strip | RS20-MARK | Port labeling for easy maintenance and troubleshooting |
| Dust Cover | RS20-DUST | Protects unused RJ45 and SC ports |
| Mounting Bracket | RS20-BRACKET | Wall / panel mounting instead of DIN rail |
- Concorrente & Confronto tra marchi
Same Series Comparison (Hirschmann RS20 Series)
| Modello | Configurazione della porta | Uplink Ports | Versione del software | Temperature Grade | Scenario applicativo |
| RS20-1600S2T1SDAUHC | 14×RJ45+1×SM SC+1×RJ45 | SC monomodale + RJ45 | Unmanaged (U) | Wide -40~+70℃ | Long-distance fiber uplink, harsh industrial environments |
| RS20-1600M2M2SDAUHC | 14×RJ45+2×MM SC | Dual Multi-mode SC | Unmanaged (U) | Wide -40~+70℃ | Short-distance fiber uplink, building automation |
| RS20-1600T1T1SDAUHC | 14×RJ45+2×RJ45 | Doppio RJ45 | Unmanaged (U) | Wide -40~+70℃ | Pure copper cable connection, simple network topology |
| RS20-1600S2S2SDAEHC | 14×RJ45+2×SM SC | Dual Single-mode SC | Basic Managed (E) | Wide -40~+70℃ | Basic network management required, long-distance fiber |
Confronto tra marchi
| Marca & Modello | Configurazione della porta | Uplink Ports | Versione del software | Intervallo di temperatura | Caratteristiche | Livello dei prezzi |
| Hirschmann RS20-1600S2T1SDAUHC | 14×RJ45+1×SM SC+1×RJ45 | SC monomodale + RJ45 | Unmanaged | -40~+70℃ | Ampia temperatura, senza ventola, complete industrial certifications | Mid-to-high |
| Phoenix Contact FL SWITCH SF 16TX/1SM | 15×RJ45+1×SM SC | SC monomodale | Unmanaged | -40~+70℃ | Redundant power, reliable Phoenix quality | Mid-to-high |
| MOXA EDS-2016-1M-S-SC | 15×RJ45+1×SM SC | SC monomodale | Unmanaged | -40~+75℃ | Extended wide temp, IP30 protection | Mid-range |
| Schneider Electric TCSESM0163F2CU | 14×RJ45+2×SM SC | Dual Single-mode SC | Unmanaged | -25~+70℃ | Seamless integration with Schneider PLC | Mid-range |
| Advantech EKI-2526SI | 16×RJ45 (2 SFP slots) | Expandable fiber | Unmanaged | -40~+75℃ | Flexible SFP configuration, conveniente | Mid-range |
- Linee guida per la selezione & Soluzioni alternative
Key Selection Considerations
- Port Type: Select uplink port type (single/multi-mode fiber, RJ45) according to network topology; single-mode for long distance (>2km), multi-mode for short distance (<2km).
- Software Function: Unmanaged (U) for simple plug-and-play scenarios; Managed (E/P) for complex networks requiring VLAN, QoS, ring redundancy.
- Intervallo di temperatura: Wide-temperature model (H) for outdoor, high-temperature workshop and harsh environments; standard model for general indoor industrial sites.
- Power Requirement: Confirm whether dual power redundancy is needed to enhance system reliability.
- Certificazione: Select products compliant with IEC 61850-3, UL 508, ISA 12.12.01 based on regional and industry standards.
Modelli alternativi consigliati
| Scenario applicativo | Modello consigliato | Motivo della sostituzione |
| Short-distance fiber uplink (<2km) | RS20-1600M2M2SDAUHC | Lower cost multi-mode fiber, suitable for intra-factory and building connection |
| Pure copper cable, no fiber required | RS20-1600T1T1SDAUHC | Dual RJ45 uplink for simple network topology and cost saving |
| Basic network management required | RS20-1600S2T1SDAEHC | Supports VLAN, QoS, HIPER-Ring ring redundancy (recovery time <300SM) |
| Sensibile al budget, cost performance priority | MOXA EDS-2016-1M-S-SC | Funzioni simili, more affordable price and wider temperature range |
| Existing Phoenix Contact system | Phoenix Contact FL SWITCH SF 16TX/1SM | High system compatibility and shared accessories |
Technical Advantages Summary
Fanless Design: Maggiore affidabilità, lower maintenance cost, adatto per ambienti polverosi.
Wide Temperature Range: -40~+70℃ operating temperature, adaptable to harsh industrial conditions.
Plug-and-Play: Unmanaged design, no configuration needed, fast deployment.
Complete Industrial Certifications: Conforme alla norma CEI 61850-3, UL 508, ISA 12.12.01, ideal for power, rail transit and other industries.
Dimensioni compatte: 130mm width saves cabinet space and supports high-density installation.
How to Select Hirschmann Industrial Ethernet Switches According to Actual Requirements
Below is a standardized 7-step selection process applicable to engineering projects, together with series positioning, industry matching and common selection pitfalls.
Fare un passo 1: Confirm Mounting Method
Determine the product series directly:
- DIN Rail Mount (Most control cabinets & automation production lines)
Scegliere: RS20 / RS30 / RS40 compact series
- 19-inch Rack Mount (Central control room & power distribution core cabinet)
Scegliere: MACH100 / MACH4000 rack-mounted series
- Outdoor Wall Mount / Cabinet-Free (Outdoor base station, tunnel, pumping station)
Scegliere: OCTOPUS IP65/IP67 waterproof series
- Panel Embedded Mount (Built-in equipment)
Scegliere: EAGLE / dedicated panel type
Fare un passo 2: Confirm Port Quantity, Port Type & Velocità
Total Port Quantity
Count PLC, HMI, instrument and camera quantities on site, prenotare 20% redundancy.
Comune: 4-porta / 8-porta / 16-porta / 24-porta.
Port Type (Core Selection Point)
RJ45 Copper Port: Indoor short distance ≤100m, standard network cable
Fiber Port: Lunga distanza & strong anti-interference
Multi-mode (MM): ≤2km, intra-factory & building interconnection, basso costo
Single-mode (SM): ≥5~15km, cross-plant road, power remote transmission, all'aperto
SFP Slot: Hot-pluggable Gigabit/100M fiber module, flexible expansion; recommended for mid-to-high-end projects.
Velocità
Ordinary PLC, strumento & monitoraggio: 10/100M Fast Ethernet is sufficient
Machine vision, big data, multi-camera & core aggregation: Full Gigabit
Fare un passo 3: Select Management Mode
Three grades based on network complexity:
- Unmanaged
Caratteristiche: Plug-and-play, zero configuration
Applicazione: Single device, simple production line, no network partition or ring redundancy
Suffisso: U
- Managed Lite
Supports VLAN, QoS, port rate limiting, basic ring network
Applicazione: Multi-workshop partition, simple isolation & basic redundancy
- Full Managed
Supports HIPER-Ring, MRP, RSTP, IGMP multicast, network security, port mirroring, allarme guasto
Applicazione: Energia, transito ferroviario, smart factory, ring topology, high reliability non-stop network
Fare un passo 4: Select Operating Temperature Grade
- Standard Temperature: 0℃~+60℃
Applicazione: Air-conditioned central control room, constant temperature cabinet
- Wide Temperature: -40℃ ~ +70 ℃
Applicazione: High-temperature workshop, all'aperto, non-air-conditioned cabinet, cold northern & hot southern environments
Industrial sites are recommended to choose wide-temperature models for higher fault tolerance.
Fare un passo 5: Power Specification & Ridondanza
- Voltaggio: Industrial standard 24VDC, some support 12~48VDC wide voltage
- Dual Power Redundancy: Mandatory for key production sections, power and rail transit; avoids network outage from single power failure
- Protezione: Protezione da inversione di polarità & surge immunity; prioritize industrial EMC protection for harsh power environments
Fare un passo 6: Network Redundancy & Special Application Requirements
- Ring Network Self-healing (Network remains online when one cable breaks)
Must choose managed switches supporting HIPER-Ring / MRP / RSTP
- Network segmentation & device isolation → Require VLAN
- Multiple cameras & streaming media → Require IGMP multicast
- Industrial security & unauthorized access prevention → Require port security & MAC binding
Fare un passo 7: Classe di protezione & Certificazione di settore
- Classe di protezione
Cabinet installation: Standard IP20
All'aperto, polveroso & humid site: IP65/IP67 OCTOPUS series
- Industry-Specific Certification
Power industry: Mandatory IEC 61850-3
Rail transit: IN 50155
Marino & al largo: Ship classification certification
Explosion-proof chemical industry: Explosion-proof grade certification
Hirschmann Main Series Positioning
| Serie | Posizionamento | Scenario applicativo |
| RS20 | Entry-level compact | Small production line, ordinary control cabinet, mostly unmanaged, conventional budget |
| RS30 | Mid-range mainstream | Gigabit SFP, basic management, piccolo & medium factory ring network, conveniente |
| RS40 | High-end industrial | Full Gigabit, full-featured management, power/rail transit/high-end smart factory |
| MACH100/4000 | Rack-mounted core | 19-inch cabinet machine room, plant-level core aggregation switch |
| OCTOPUS | Outdoor waterproof | All'aperto, tunnel, pumping station, cabinet-free on-site installation |
Industry Recommended Selection
- General Automation Production Line / Workshop
8/16-port RS20 wide-temperature unmanaged — cost-effective and sufficient
- Multi-workshop Ring Network / Smart Factory
RS30 Gigabit SFP managed with ring network support
- Power Substation / PV & Wind Power
RS40 wide-temperature + IEC61850 certification + dual power redundancy
- Transito ferroviario / Tunnel Outdoor
OCTOPUS IP67 waterproof + ampia temperatura + rail transit certification
- Central Control Room Core Aggregation
MACH rack-mounted full Gigabit
Common Selection Pitfalls
- Do not blindly choose full Gigabit; 100M is enough for ordinary PLC and wastes budget.
- Avoid standard temperature models for industrial sites; cabinet overheating easily occurs in summer.
- Use single-mode fiber ports for long-distance cross-plant connection; do not use network cables for long-distance laying.
- Ring topology must use managed switches; unmanaged switches cannot implement ring redundancy.
- Key equipment must adopt dual power redundancy to prevent entire network paralysis from single power failure.
Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari