Dimensioni: 80×80×38mm (8038), Dual-ball bearing, 2-wire version (power supply only, no tachometer feedback). Widely used for cooling inverterS, servoazionamenti and industrial control cabinets.
Specifiche elettriche principali
| Articolo | Parametro |
| Modello | 3115RL‑05W‑B60 |
| Tensione nominale | DC 24V (Raggio d'azione:14‑27.6V) |
| Corrente nominale | 0.5UN (Typical 0.4A) |
| Energia | 9.6‑12W |
| Velocità | 5500giri al minuto |
| Flusso d'aria | 79.2CFM ≈134.6m³/h |
| Pressione statica | 180Papà |
| Rumore | 51dB(UN) |
| Cuscinetto | Dual‑ball bearing |
| L10 Life | 50000h @25℃ |
| Cablaggio | 2-filo: Red=24V+, Black=GND‑ |
| Peso | 210G |
⚠️Suffix Distinction (Easily Confused within the Series)
B60: 2-filo, no tachometer feedback
B69: 3-filo, with tachometer (TACH) speed feedback
B66: 4-filo, PWM speed control + tachometer feedback
Dimensioni di montaggio
Flange cutout: 71.5×71.5 mm
Fori di montaggio: Viti M4, hole pitch 71.5mm
Spessore: 38mm
Scenari applicativi
Cooling for inverters (per esempio. ABB ACS880), servoazionamenti, high-power power supplies and industrial equipment enclosures.
OEM Status: NRND (Not Recommended for New Designs). Recommended replacement part number: 08038RA-24P-EA-00.
Compatibilità & Sourcing Criteria for Domestic Alternatives
All conditions must be satisfied simultaneously:
- Form factor 80×80×38mm
- DC24V, rated current ≥0.45A, speed 5200-5600RPM
- Dual-ball bearing
- Matching wiring: Do NOT select 2-wire B60 variant if equipment requires speed-monitoring signal.
Diagnosi dei guasti
- Fan does not spin upon power-on: Verify 24V input voltage. Manually spin impeller when power is cut off. If locked-up, bearing damage has occurred; replace directly.
- Bassa velocità & rumore anomalo: Bearing wear. Do not attempt repair in industrial environments; replace the fan.
- Nota importante: B60 is a 2-wire fan without tachometer alarm output. If host equipment reports fan fault, the original unit requires B69 (3-wire tachometer version). B60 cannot be used as a drop-in replacement.
Replacement List for NMB 3115RL-05W-B60 (8038-24V-2-wire)
Key parameters of original fan: 80×80×38mm|DC24V|0.5A|5500RPM|Dual-ball bearing|2-wire no tach feedback|71.5mm mounting pitch
⚠️Critical Reminder: If the inverter triggers fan fault alarm, original hardware requires 3-wire tachometer B69. Do not apply 2-wire B60 or any 2-wire substitutes.
- OEM Direct Replacement (NMB)
| Modello | Cablaggio | Osservazioni |
| 08038RA‑24P‑EA‑00 | 2-filo | Official NRND upgrade part. Fully form‑fit‑function compatible, direct drop‑in replacement for 3115RL‑05W‑B60 |
- Delta / Sunon Foreign-brand Compatible Models
| Modello | Voltaggio | Attuale | Velocità | Cablaggio | Osservazioni |
| PFB0824GHE | 24V | 0.54UN | 5400giri al minuto | 2-filo | Delta, high static pressure, widely used as inverter replacement |
| PF80382B1‑000C‑A99 | 24V | 0.5UN | 5500giri al minuto | 2-filo | sole, dual‑ball bearing, perfectly matched dimensions |
- Domestic Industrial Alternatives (General for Inverters & Armadi di controllo)
| Modello | Voltaggio | Attuale | Velocità | Cablaggio | Caratteristiche |
| SJ8038HD2‑24 | 24V | 0.5UN | 5400‑5600RPM | 2-filo | Dual‑ball bearing, wide‑temperature, common spare part for domestic inverters |
| RD8038B24H | 24V | 0.5UN | 5500giri al minuto | 2-filo | RUNDA, copper‑winding dual‑ball bearing, cost‑effective option |
| FS8038‑24‑050 | 24V | 0.5UN | 5500giri al minuto | 2-filo | Industrial‑grade domestic fan, built‑in reverse‑connection protection |
✅Mandatory Checklist Prior to Replacement
- Form factor: 80×80×38mm, mounting hole pitch 71.5mm for M4 screws
- Cuscinetto: Dual-ball bearing is mandatory. Sleeve bearings have short service life and are not recommended for industrial sites.
- DC24V power supply, rated current ≥0.45A. Insufficient current causes insufficient airflow and over-temperature protection.
- Wiring specification: 2-filo: Red=24V+, Black=GND-. If equipment has fan fault alarm function, select 3-wire model with TACH tachometer output.
- Gamma di velocità: 5200-5600giri al minuto. Too low speed yields insufficient static pressure & flusso d'aria, triggering inverter over-temperature tripping.
⚠️Common Pitfalls
- 8025 (25 mm thickness) cannot replace 8038. Thickness difference of 13 mm prevents installation.
- Avoid low-current 0.3A variants; insufficient airflow and static pressure will cause high-temperature alarms.
- B60 is 2-wire without speed feedback. Some ABB ACS880 units are factory-fitted with B69 (3-wire tachometer). Direct installation of B60 will trigger fan fault alarms.
Typical Application Scenarios of NMB 3115RL-05W-B60 (DC24V 8038 2-filo)
Funzionalità principali: Alta pressione statica, 5500giri al minuto, dual-ball bearing, 2-wire without tach feedback, DC24V supply. Suitable for forced cooling inside equipment with high-resistance air ducts. Not applicable for systems requiring fan-fault alarm.
- Invertitori (Most Common Deployment)
- Internal cooling fans for certain high-power Schneider inverters, power range 7.5-30 kW air duct cooling.
- Post-mounted cooling fans for high-power domestic inverters (Innovazione, Invt, Delta etc.), for models without fan-speed monitoring.
⚠️Note: ABB ACS880 is mostly factory-equipped with B69 (3-wire tachometer). B60 cannot be directly substituted, otherwise fan fault alarm will occur.
- Servoazionamenti / Motion Control Units
- Internal power-module cooling for high-power multi-axis servo units;
- Air duct cooling for numerical-control drive units and machine-tool servo control cabinets.
Applicable condition: Equipment only supplies power to fan, no fan-speed detection & alarm function.
III. Industrial Power & Power-Electronic Equipment
- High-power DC24V industrial switching power supplies & charging modules;
- Power-cavity cooling for medium-small UPS uninterruptible power supplies;
- Auxiliary cooling for energy-storage converters and compact energy-storage modules;
- Power-device cooling for high-frequency welders and plasma power sources.
- Industrial Chassis & Armadi di controllo
- Exhaust ventilation inside compact industrial control cabinets;
- Forced ventilation for industrial IPC & industrial host chassis;
- Auxiliary cooling inside robot control cabinets.
24 VDC input, can be directly driven by PLC 24V power supply, no extra AC-DC converter required.
- Altre attrezzature industriali
- Apparecchiature laser: Cooling for laser power supplies and laser controller enclosures;
- Industrial medical equipment: Power-module cooling for non-life-support industrial medical instruments;
- Rail-transit equipment: Cooling for on-board control boxes and vehicle-mounted power modules;
- Stage-lighting equipment: Internal cooling for high-power moving-head beam lights;
- Apparecchiature per l'automazione: Control-box cooling for textile, printing and packaging machinery.
✅Key Engineering Application Restrictions
- B60 is 2-wire with no tachometer feedback. Never select B60 if host equipment implements fan-fault alarm; choose B69 (3-wire tachometer) variant instead.
- High-static-pressure characteristic: Optimized for air ducts with radiators, baffles and filter screens. For open cabinet ventilation, low-static-pressure general-purpose fans are acceptable.
- Alimentazione elettrica: DC24V only. Do NOT connect to AC220V. Allowable operating voltage:14-27.6V.
- OEM lifecycle status: NRND (Not Recommended for New Designs). For new-project design, use official replacement part 08038RA-24P-EA-00.
Service Life of NMB 3115RL-05W-B60 Fan
This fan adopts dual-ball bearing. NMB official datasheet specifies:
50000 hours @25℃ free-air condition (L10 life).
Definition of L10 Life
L10 life: Statistically, 90% of fans within a batch can achieve this runtime; 10% will fail earlier. It is NOT a guaranteed service life for every single unit.
Expected Service Life under Different Operating Conditions
| Ambiente operativo | Expected Service Life | Osservazioni |
| 25℃, pulito & low‑dust, continuous running | 40000‑50000h | Lab ideal condition |
| 40‑50℃, industrial cabinet, moderate dust | 20000‑30000h | Typical working condition for inverter & servo cabinets |
| >60℃ high temperature, polvere pesante & nebbia d'olio | 8000‑15000h | Significant life reduction; premature bearing wear, noise and speed drop |
| Intermittent start‑stop operation | Relatively extended life | Less bearing wear with fewer start‑stop cycles |
Reference conversion: 50000 h continuous operation ≈ 5.7 years of 24-hour non-stop runtime. Industrial field conditions rarely reach theoretical rating; noise degradation is commonly observed after 3-4 years of service.
Sintomi tipici di guasto
- Increased noise & abnormal rattling (ball-bearing wear)
- Calo di velocità, degraded airflow & pressione statica, triggering system over-temperature alarms
- Hard to start; fan requires manual spin-up upon power-on, eventually locks up completely.
Practical Engineering Recommendations
- For continuously-running industrial equipment, perform preventive replacement every 2-3 anni. Avoid unplanned shutdown caused by fan seizure and consequent inverter over-temperature tripping.
- Install filter screens for dusty cabinet environments and conduct regular dust removal to extend fan service life.
- This model is NRND. New-project design shall adopt replacement part 08038RA-24P-EA-00, updated bearing process with identical life rating.
Supplementary Comparison
Equivalent-size sleeve-bearing fans: Typical service life 8000-15000 h, not recommended for industrial deployment.
B69 (3-wire tachometer version) shares identical bearing hardware with B60, same theoretical service life, only adds tachometer circuit.
Real-world Engineering Application Cases of NMB 3115RL-05W-B60 (2-wire 24V 8038)
Important premise: B60 is 2-wire fan without tachometer feedback. Only deploy in equipment without fan-speed detection & allarme guasto. Systems with fan-fault protection require B69 (3-wire tachometer), direct substitution is invalid.
- Inverter Sector (Most Frequently Encountered in Teardowns)
Caso1: Cooling for 15-18.5 kW Domestic Inverters
Attrezzatura: Innovazione MD380, Invt CHV series high-power inverters, selected Delta high-power inverters
Condizioni operative: 24-hour continuous operation for textile & injection-molding machines. High-resistance radiator air duct requiring high static-pressure fan. Equipment does not monitor fan speed, powered directly by internal DC24V supply.
Failure phenomenon: After 3-4 years runtime, bearing wear causes abnormal noise and airflow reduction, triggering inverter over-temperature shutdown. Issue resolved by replacing with 3115RL-05W-B60 or domestic equivalent.
⚠️ABB ACS880 is factory-equipped with B69 (3-wire tachometer). B60 direct swap triggers fan fault alarm.
Caso2: Low-power hoist / lifting-machine inverters
-Attrezzatura: 11-22 kW hoist-dedicated inverters deployed in overhead cranes & lifting-mechanism control cabinets.
-Condizioni operative: Heavy-dust site with mixed intermittent-continuous operation. Fan mounted rear-side of power-module radiator for forced draw-through cooling.
- Servo & Numerical-control Equipment Cases
Caso3: High-power multi-axis servo drives (no fan-monitoring variant)
-Attrezzatura: Domestic multi-axis servo units, machine-tool servo control cabinets; no fan-speed monitoring programmed in controller firmware.
Condizioni operative: Cabinet ambient temperature 40-50 ℃ inside CNC lathe & machining-center control enclosures. Fan provides forced cooling for servo power boards and IGBT power modules.
Repair scenario: Seized fan causes servo-module over-temperature & power derating; service restored after B60 replacement.
Caso4: Legacy CNC system power-supply units
Attrezzatura: Older-generation machine-tool high-power power-supply boxes with internal DC24V power rail.
Caratteristica: Equipment only supplies power to fan without speed reading; 80×80×38 mounting footprint accepts this fan directly.
III. Power-supply Sector Cases
Caso5: Industrial high-power DC24V charging-power modules
Attrezzatura: Automation-equipment charging power supplies, welder power supplies, plasma-cutting power sources.
Condizioni operative: Metal-dust-laden welding-shop environment. Fan installed behind radiator, high static pressure overcomes filter-screen and duct resistance.
Caso6: Medium-small-size industrial UPS
Attrezzatura: 5-10 kVA industrial UPS units for internal power-component cooling.
Caratteristica: Powered directly from UPS internal 24 VDC busbar; no additional AC-DC conversion required.
- Mobiletto & Automation-equipment Cases
Case 7: Auxiliary cooling for robot secondary control cabinets
Attrezzatura: External expansion control cabinets for robots (not robot native built-in fans).
Condizioni operative: Production-line cabinet exhaust ventilation. Driven by PLC DC24V power supply, pure exhaust function without fault-detection logic.
Case 8: Laser-equipment power-supply enclosures
Attrezzatura: Fiber-laser power supplies and laser-controller cabinets.
Condizioni operative: Smoke-laden laser-processing workshops. Fan pushes air through filter screens for power-component cooling. High static pressure and dual-ball long-life are critical requirements.
- Other-industry Real-world Cases
Case 9: High-power stage-lighting equipment
Attrezzatura: High-power beam moving-head lights, internal power-module cooling.
Condizioni operative: High-temperature high-vibration venue environment; dual-ball bearing provides vibration resistance, Ingresso alimentazione DC24V.
Case 10: Rail-transit on-board control cabinets
Attrezzatura: Vehicle-mounted electrical cabinets and metro auxiliary control modules (non-safety-critical loops).
Condizioni operative: 14-27.6 V wide-voltage input accommodates vehicle-bus voltage fluctuation. Dual-ball bearing tolerates bump and vibration.
📌Real-world Maintenance Pitfall Case
Fault scenario: Maintenance technician replaces factory-fitted B69 (3-wire tachometer) with B60 (2-filo) on ABB ACS880 inverter. Fan-fault alarm activates upon power-on and equipment refuses to run.
Causa ultima: B60 provides no tachometer-feedback signal for inverter speed detection.
Risoluzione: Install B69 variant. Disabling fan-fault detection in firmware is possible but not recommended, as thermal protection is lost.
Project-sourcing Reference
- Spare-part replacement for legacy equipment: Use same B60 part number if original unit is B60.
- New-project design: Model is NRND, prioritize official replacement 08038RA-24P-EA-00.
- If equipment has fan-fault alarm function: B60 is strictly prohibited, select B69 (3-wire tachometer).
Additional Industrial Applications for NMB 3115RL-05W-B60 (Excluding Inverters, Servi & Attrezzatura CNC)
Core premise: 2-wire without tachometer feedback; host equipment must have no fan-fault alarm function. High-static-pressure 8038 DC24V dual-ball-bearing fan optimized for filter-screen & radiator-restricted air ducts.
1️⃣ Laser-processing Equipment
- Fiber-laser power supplies & YAG laser power boxes: Power-component cooling for laser cutters & laser markers. Overcome smoke-filter-screen resistance for 24-7 factory-continuous operation. Equipment only supplies power, no fan-speed detection.
- Laser-welding-machine control cabinets: Forced air-cooling for laser-driver modules, deployed in metal-dust-heavy sheet-metal-processing workshops.
Maintenance case: Bearing wear reduces airflow and degrades laser-output power; performance restored after B60 replacement.
2️⃣ Welding & Plasma-cutting Equipment
- Inverter plasma-cutting power supplies: IGBT radiator cooling for metal-dust-rich workshop environments. High static pressure penetrates dust-proof screens.
- Industrial inverter welders & high-frequency induction-heating power supplies: High-power solid-state-component cooling via on-board DC24V supply.
3️⃣ Power-supply, Energy-storage & UPS Industry
- High-power industrial DC-DC switching power supplies & charging modules: Internal cooling for automation-equipment power supplies and electronic-load test benches.
- Medium-small-size industrial UPS (5-10 kVA): Power-cavity cooling powered directly by UPS internal 24 VDC busbar.
- Compact energy-storage modules & residential energy-storage converter auxiliary cooling: Apply only to non-safety-critical circuits without fan-diagnostic logic.
4️⃣ Industrial Chassis & Robot Auxiliary Electrical Cabinets
- Industrial IPC & compact sealed industrial chassis: Internal exhaust ventilation for filter-equipped enclosures.
- Robot external expansion control cabinets (not robot native internal fans): Exhaust ventilation for production-line robot auxiliary cabinets, driven by PLC DC24V power supply.
- ATE test-equipment cabinets & automated-test platforms: Power-module cooling for automatic-test-system hardware.
5️⃣ Rail-transit & Vehicle-mounted Industrial Equipment (Non-safety-critical Loops)
- Metropolitana / train auxiliary on-board control boxes and vehicle-mounted signal peripheral cabinets: 14-27.6 V wide-voltage range accommodates vehicle-bus voltage fluctuation; dual-ball bearing resists mechanical shock and vibration.
Nota: Safety-relevant on-board hardware normally specifies B69 tachometer variant. B60 is limited to non-safety-critical circuits.
6️⃣ Stage-lighting & Audio-visual Equipment
- High-power beam moving-head lights & stage high-power LED luminaire power compartments: High-vibration venue environment; dual-ball bearing anti-vibration performance, DC24V power supply.
- High-power industrial power amplifiers & public-address power-amplifier enclosures.
7️⃣ Semiconductor & SMT Automation Equipment
- SMT pick-and-place machine auxiliary power boxes & PCB-inspection-equipment electrical enclosures: Sub-module cooling (main-unit fans use dedicated tachometer-equipped variants).
- Dispensing machines & spray-coating-equipment control-box cooling.
8️⃣ Other Specialized Industrial Equipment
- Stampa & textile-machinery electrical cabinets: Power-unit cooling inside printing presses and warp-knitting-machine control enclosures.
- Laboratory high-power instrumentation: High-power electronic loads and burn-in-test benches.
- Packaging-machinery electrical cabinets.
⚠️Hard Sourcing Rules for Engineering Practice
- B60 is 2-wire and has no speed-signal output. Never deploy B60 for any equipment with fan-fault-alarm or fan-stall-detection logic; select B69 (3-wire tachometer) instead.
- Prefer this fan for air ducts fitted with radiators and filter screens. Low-static-pressure general-purpose fans suffice for open unrestricted-airflow cabinet ventilation.
- OEM lifecycle status: NRND. New-project design prioritizes official replacement part 08038RA-24P-EA-00.
- For dusty / oil-mist industrial environments, schedule preventive replacement every 2-3 years to avoid unexpected equipment over-temperature shutdown.