Schneider C10F32D100: Interruttore automatico scatolato ComPacT NSX100F

Model Interpretation C10F32D100 is the complete order code of Schneider’s new-generation ComPacT NSX series molded case circuit breakers. The meaning of each segment is as follows: Code Segment Meaning Description C10 Frame Size and Breaking Capacity C10 = NSX100F, frame current 100A, breaking capacity Class F (36kA@415VAC) F Breaking Capacity Class F = 36kA@415VAC, suitable ...

  • Dettagli del prodotto
  1. Interpretazione del modello

C10F32D100 is the complete order code of Schneider’s new-generation ComPacT NSX series molded case circuit breakers. The meaning of each segment is as follows:

Segmento di codiceSensoDescrizione
C10Frame Size and Breaking CapacityC10 = NSX100F, frame current 100A, breaking capacity Class F (36kA@415VAC)
FClasse del potere di interruzioneF = 36kA@415VAC, suitable for standard industrial applications
3Numero di poli3 = 3-pole (3P3D, three-phase three-wire system)
2DTipo di unità di sgancio2D = MicroLogic 2.2 electronic trip unit with display function
100Corrente nominale100UN, adjustable range 90-100A
  1. Parametri tecnici fondamentali

Parametri di base

ParametroValoreDescrizione
Tipo di prodottoInterruttore automatico scatolato (MCCB)New-generation ComPacT NSX100F
Tensione nominale690VAC/50-60HzMaximum operating voltage
Corrente nominale (Iu)100UNContinuous operating current
Ultimate Breaking Capacity (terapia intensiva)36kA@415VACUltimate breaking capacity
Service Breaking Capacity (IC)36kA@415VAC (100%)Service breaking capacity
Tipo di montaggioFissoStandard mounting, plug-in type optional (C10F32D100P)
Protection CategoryCategory AConforme all'IEC 60947-2 standard

MicroLogic 2.2 Trip Unit Parameters

Funzione di protezioneCharacteristicAdjustable Range
Long-time Delay Protection (l)Protezione da sovraccarico, inverse time-lag0.8-1.0脳Iu (90-100UN)
Short-time Delay Protection (S)Protezione da cortocircuito, definite time-lag3-6脳Iu, regolabile
Instantaneous Protection (IO)Short-circuit instantaneous tripping, fisso10脳Iu (1000UN)
Funzione di visualizzazioneCurrent measurement and status indicationReal-time display of three-phase current

Physical and Electrical Characteristics

ParametroValore
Power Loss14.1W
PesoApproximately 2.5kg
Standard di conformitàCEI 60947-2, GB 14048.2
CertificazioniCE, CCC, RoHS

III. Caratteristiche funzionali

  1. Comprehensive Protection: Provides three-stage protection including long-time delay, short-time delay and instantaneous protection, effectively preventing overload and short-circuit faults.
  2. Precise Control: Compared with thermal-magnetic trip units (TM series), electronic trip units offer more accurate protection curves and adjustable parameters.
  3. Status Visualization: MicroLogic 2.2 is equipped with LED display for real-time monitoring of current and fault status.
  4. Design modulare: Supports a variety of accessories (contatti ausiliari, alarm contacts, sganciatore di minima tensione, ecc.) for flexible installation.
  5. Environmental Friendly: Schneider Green Signature design, reducing energy consumption and carbon footprint.
  6. Funzionamento facile: Ergonomic handle for labor-saving operation; front-mounted accessories reduce wiring time by 40%.
  7. Scenari applicativi
  8. Industrial Power Distribution Systems: Used as main switch or branch switch to protect motors, transformers and distribution lines.
  9. Realizzazione di impianti elettrici: Low-voltage distribution cabinets in commercial buildings and industrial plants.
  10. Motor Control Centers (Centro clienti): Protect three-phase motors from locked rotor and overload conditions.
  11. Centri dati: Power protection for critical loads to ensure power supply continuity.
  12. New Energy Sector: DC-side protection of photovoltaic inverters and energy storage systems (additional configuration required).
  13. Product Comparison

Comparison with Trip Units of the Same Series

ModelloTipo di unità di sgancioPrincipali differenzeScenari applicativi
C10F32D100MicroLogic 2.2Electronic trip unit with display, three-stage protectionIndustrial applications requiring precise protection and monitoring
C10F3TM100TM100D Thermal-Magnetic TripSganciatore magnetotermico, two-stage protection, convenienteSimple power distribution without precise adjustment requirements
C10F33D100MicroLogic 3.2Added earth fault protection (30-3000mA)

Comparison with Chint Alternative Models

Schneider ModelChint Alternative ModelSomiglianzeDifferenze
C10F32D100NM1-125S/3300 100A3-palo, 100UN, 36potere di interruzione kAChint adopts thermal-magnetic trip unit without display; Schneider adopts electronic trip unit with display
NM1-125H/3340 100A3-palo, 100UN, electronic trip unitChint has 50kA breaking capacity with slightly different protection functions
  1. Selection and Usage Recommendations
  2. Punti chiave della selezione

Select protection curves according to load types: per carichi motore, it is recommended to set short-time delay to 5-6×Iu

Breaking capacity should be greater than the expected short-circuit current of the system

Consider future expansion; rated current should be slightly higher than the actual load current

  1. Precauzioni per l'installazione

Ensure the mounting surface is flat and the tightening torque meets requirements (screw torque 25N·m)

Corresponding cable lugs must be used for terminal connections to avoid heating caused by poor contact

Leave sufficient heat dissipation space around and avoid close installation with heat-generating components

  1. Raccomandazioni per la manutenzione

Ispezione regolare (almeno una volta all'anno): aspetto, tightness status, flexibility of operating mechanism

Check contact condition after short-circuit tripping and replace if necessary

Clean with dry compressed air to avoid moisture and dust accumulation

VII. Troubleshooting Guide

Fenomeno di guastoPossibili causePassaggi per la risoluzione dei problemi
Failure to Close1. Undervoltage release without power supply

2. Trip unit malfunction

3. Mechanical lockout

1. Check control power supply (se equipaggiato)

2. Measure trip unit coil resistance

3. Manually reset the trip mechanism

Falso intervento1. Sovraccarico

2. Cortocircuito

3. Improper trip unit parameter setting

1. Check load current

2. Check line insulation

3. Reset trip unit parameters

No Display After Tripping1. Trip unit power supply failure

2. Trip unit damage

1. Check trip unit power supply

2. Replace the trip unit