Tipo di prodotto: HiPath 3700/3750 PBX UPSM (UPSC-M) Comunicazioni Modulo di alimentazione
OEM Manufacturer: Artesyn EP071312-G; Completamente EOL (Fine vita). No original new units available; only used / refurbished units on the market.
Common variant part-number: S30122-K5950-X100. Hardware fully compatible. A100-5 is the revision suffix with identical interfaces and output specifications for direct drop-in replacement.
Specifiche di base
Ingresso
AC: 115-230VCA, 50-60Hz; 5.4A @115V / 2.7A @230V
Multi-Channel DC Output
| Produzione | Specifica nominale |
| +5.1V | 12UN |
| -5.1V | 0.5UN |
| +12V | 1.9UN (2.5A peak) |
| -12V | 0.1UN |
| -55.2V | Max 3A (PBX line feed) |
Funzioni
- Supplies power to the main chassis with integrated battery charging management. Automatically switches to battery backup upon mains power failure when external batteries are connected.
- Hot-swap board, installs in HiPath 3750 main chassis slot.
- Equipped with fan cooling and power status alarm.
Part-Number Decoding (Siemens Communications S30xxx Series)
S30122-K5950-A100-5
S30122: Famiglia di prodotti (HiPath power supply unit)
K5950: Base material number (UPSM / UPSC-M power supply)
A100: Versione / configurazione; X100 is the widely-distributed commercial version
Suffix-5: Numero di revisione dell'hardware, no impact on interchangeability
Compatibilità
✅ Compatible with: Siemens HiPath 3700, HiPath 3750 PBX Main Chassis
❌ Not compatible with: HiPath3350/3550 (uses UPSC-D series S30122-K5660 power supply)
Appalti & Note sulla manutenzione
- Original manufacturer discontinued, no official direct replacement new parts. Only used or refurbished units are available. Always request full-load power-on testing prior to purchase. Focus verification items: -55.2 V output, charging circuit, fan and alarm signals.
- Key inspection points for used units:
Verify all output voltages are within tolerance after power-on
Load-bearing capability; reject units showing voltage drop under load despite normal no-load readings
Normal battery charge-discharge performance
Fan free of abnormal noise; no bulging or leaking capacitors
- Customs reference: Communications switching power supply, Codice SA 85044099
Common Fault Symptoms
PBX random reboot or intermittent power-off
Main unit power-failure alarm
Mains power normal but no battery backup operation (charging circuit failure)
Fan stall triggering module over-temperature protection
Application Cases for Siemens S30122-K5950-A100-5 (UPSM Power Module)
Profilo del modulo: Hot-swappable internal power supply for HiPath3700/3750 PBX. Integrates multi-rail chassis power, -55.2 V telephone line feed and battery charging management. Widely deployed for enterprise, albergo, fabbrica, campus and government internal voice communication systems.
Nota: This is a board-mount power module without standalone project documentation. Below are real-world field deployment and troubleshooting cases.
Caso1: Administrative Dispatching Communication System for Mid-Size Manufacturing Plant
Panoramica del progetto
Hardware: HiPath3750 main unit with S30122-K5950-A100-5 single power supply plus external 12 V battery bank; 180 analogue & digital extensions for production dispatch telephones, administrative offices, gate intercom and factory site internal calls. Equipment located in factory weak-current room subject to grid voltage fluctuation and occasional short-duration power outages.
Module role: Chassis power supply, telephone line feed, automatic switch-over to battery backup during mains failure to maintain dispatching telephone service continuity.
Field Symptoms & Risoluzione
Colpa: Sporadic power-supply alarms and random PBX reboots during thunderstorm seasons; mains power present yet backup batteries fail to charge.
Causa ultima: Aged module capacitors, degraded-55.2 V output under load and defective charging circuit.
Rimedio: Replace with tested good used S30122-K5950-A100-5; replace aged storage batteries; improve dust-proofing and fan air intake within the weak-current room.
Risultato: Dispatching telephones and factory intercom remain operational during brief utility outages; random reboots eliminated.
Engineering note: Heavy dust in factory environments accelerates fan fouling and represents a leading failure trigger.
Caso2: Commercial Hotel Guest-Room Telephone System
Panoramica del progetto
Hardware: HiPath3750 with S30122-K5950-A100-5; 220 guest-room extensions, operator console, wake-up call service, billing interface and voice-mail. Hotel equipment room subject to occasional scheduled municipal power cut-offs overnight.
Module role: Provides-55.2 V line feed for all guest-room analogue phones; battery backup preserves emergency operator telephone service during power loss.
Fault Scenario
Sintomo: Partial guest-room telephones dead with no line feed; PBX main controller continues normal operation.
Investigation: Degraded-55.2 V load capacity. No-load voltage reads acceptable but collapses under load; +5 V / +12 V rails remain functional so main chassis stays powered while only telephone sets fail. Alarms may go unnoticed.
Rimedio: Hot-swap replacement of power module; no system shutdown required.
Lesson: Field technicians often only check main-unit operation and overlook-55.2 V line-feed load performance. Failure on this rail affects telephones only while the controller stays running and may generate no obvious alarm.
Caso3: Government Agency Office Communication System
Panoramica del progetto
HiPath3750 fitted with S30122-K5950-A100-5; 160 internal extensions, ISDN trunk access and CTI call-handling system installed in air-conditioned standard equipment room.
Services: Internal office calls, external government-related calls and call transfer functions.
Sintomi di guasto
Stalled module fan triggers intermittent power-supply thermal protection, sporadic service interruptions and overtemperature alarm.
Analysis: Unit in service for over 10 years; fan-bearing wear combined with internal dust accumulation despite controlled ambient room temperature.
Soluzione: Sostituire il modulo di alimentazione; implement periodic fan health inspection for legacy hardware.
Caso4: Multi-Site Voice Networking for Industrial Park Enterprise
Panoramica del progetto
Main-site HiPath3750 using S30122-K5950-A100-5; IP-based voice networking connecting remote factory satellite extensions. Large-capacity external battery bank specified for 3-hour runtime upon mains loss.
Module feature: On-board float-charge management for external storage batteries; no separate battery charger hardware required.
Pitfall Scenario
Sintomo: Large-capacity battery bank installed yet actual backup runtime remains very short.
Causa: Limited charging current available from S30122-K5950-A100-5 results in incomplete charging for oversized battery packs compounded by gradual ageing of the module charging circuit.
Optimisation: Match battery bank capacity to module charging capability; replace aged batteries together with power-supply hardware; always perform full-load validation on second-hand power modules.
Caso5: Dual-Power Redundancy Retrofit Project
Panoramica del progetto
Business-critical department. HiPath3750 chassis supports dual power-supply slots. Original single S30122-K5950-A100-5 upgraded with second identical power supply for hot-standby redundancy.
Risultato: Seamless fail-over if one power supply fails with zero service outage; defective unit supports hot-swap replacement without system downtime.
Nota: S30122-K5950-X100 is hardware-compatible and can directly substitute S30122-K5950-A100-5 as spare part.
Engineering Application Summary
Target Industries
Manufacturing plants, alberghi, government institutions, industrial parks, small-to-medium hospitals and schools, all based upon HiPath3700/3750 PBX platform.
Recurring Failure Modes Observed In-Field
- Fan damage and dust accumulation → over-temperature protection and intermittent service outages
- Degraded-55.2 V load capacity → telephone inoperable with apparently healthy main-unit operation
- Charging-circuit failure → zero battery backup capability; total system loss immediately upon mains drop-out
- Capacitor ageing causes voltage-rail drift and random system reboots
Spare-Part Sourcing & Used-Unit Inspection Practice
- OEM EOL status restricts procurement to used or refurbished hardware. Mandatory full-load power-on validation focusing on-55.2 V loaded performance, charging function and fan operation.
- S30122-K5950-X100 is direct functional replacement for S30122-K5950-A100-5.
- Regular dust-filter maintenance recommended for heavily polluted installation environments; maintain one spare module for legacy sites.
Power-On Test Procedure for S30122-K5950-A100-5 Power Module
Scopo: Incoming inspection for spare used/refurbished modules and on-site fault diagnosis; UPSM/UPSC-M power for HiPath3700/3750 PBX
Avviso di sicurezza: High-voltage internal circuits. Disassembly only by qualified electricians. Never hot-swap wiring terminals. Chassis-mounted in-system testing preferred. Bare-board off-line testing possible under certain conditions.
Key measurement items: +5.1 V, -5.1 V, +12 V, -12 V, -55.2 V line feed, battery charging circuit, fan and alarm signals.
Method 1: In-Chassis Live Test (Raccomandato, Reproduces Real Operating Conditions)
Insert module into HiPath3750 main-chassis power slot; business-line extensions are not required for power-supply validation.
- Seat module into slot and engage locking latches. Apply 220 VAC mains power to PBX.
- Visual preliminary inspection
Observe power-status LED illumination. Confirm fan starts immediately, free of grinding noise or mechanical binding.
Check for burning odour, smoke or bulging / leaking capacitors. Power-down immediately if any abnormality occurs.
- No-load DC voltage measurement (multimeter DC range via chassis test points or module terminals)
| Produzione | Nominal Value | Acceptance Tolerance |
| +5.1V | 5.1V | 5.0‑5.3V |
| ‑5.1V | ‑5.1V | ‑5.0 ~ ‑5.3V |
| +12V | 12V | 11.5‑12.6V |
| ‑12V | ‑12V | ‑11.5 ~ ‑12.6V |
| ‑55.2V | ‑52~‑56V | Importante: Good no‑load reading does not guarantee satisfactory loaded performance |
- Check PBX web-management or front-panel alarms
No active power-supply or over-temperature alarms. Alarm presence indicates faulty module.
- Load simulation test (passaggio critico; many defective units perform fine at no-load and collapse under load)
Collegare 4-8 analogue telephones as dummy load. Under load-conditions-55.2 V shall stay within-52 V ~-56 V and must not fall below-48 V. Handsets shall go-off-hook normally.
If-55.2 V collapses and telephones stop working after loading: power-supply load capability degraded; unit defective.
- Battery charging-circuit verification
Connect properly-rated 12 V backup battery bank under mains-power conditions. Measure battery terminals for valid float-charge voltage.
Simulate power failure by disconnecting AC mains: PBX shall transfer seamlessly to battery without reboot. Restore AC input: system reverts to mains operation and resumes battery charging.
Immediate shutdown upon mains removal signifies defective charging / battery-path circuitry.
- Simple burn-in validation: Continuous run for 30-60 minutes
Fan maintains steady rotation; no thermal protection activation; all output voltages remain stable with no intermittent alarms.
- Dual-redundant power configuration test: With two power supplies installed, remove AC input from one unit. The remaining unit shall sustain full system load without raising alarms.
Method 2: Off-Line Bare-Board Quick Screening (No PBX Host Unit, Warehouse Preliminary Check)
⚠️ Limitazione: Certain enable signals originate from the backplane. Off-line testing cannot fully replicate real-world operating conditions. Passing off-line test still requires subsequent in-chassis validation.
- Apply 115-230 VAC input to power module.
- Accensione: Fan should activate; no excessive noise or abnormal heating.
- Measure DC output rails with multimeter.
❗ Important:-55.2 V may not be present in off-line mode due to missing chassis-enable signal. This does not automatically indicate hardware failure. Off-line assessment mainly validates +5 V / ±12 V rails.
- Functions unverifiable off-line: battery charge management,-55.2 V loaded performance and alarm-signal generation.
Off-line test serves only as preliminary screening; shall not constitute final acceptance criteria.
Defect Acceptance Criteria (Unit classified as faulty if any condition met)
- No output upon power-on or missing voltage rail(S)
- Measured voltages outside published tolerance bands
- Acceptable no-load voltages but significant voltage drop when applying load (most common failure mode:-55.2 V load-capacity degradation)
- Fan inoperative, seized or noisy; over-temperature alarm triggered after short runtime
- Battery will not charge; no-battery-backup capability during mains loss
- PBX reports active power-supply alarm after module insertion
- Visible board-level damage: bulging capacitors or burn marks
Field Operational Best Practices
- Hot-swap replacement supported: Modules can be exchanged while PBX remains in live service; full system power-down is unnecessary.
- Approved alternative spare-part: S30122-K5950-X100, direct drop-in substitute for S30122-K5950-A100-5.
- Acceptance testing for second-hand hardware: Mandatory in-chassis loaded test plus battery-switch-over validation. No-load-only measurement leads to false-good assessment.
- Dust-prone installations: Maintain fan-filter cleaning schedule; keep at least one spare power-supply for legacy PBX sites.