ブランドの歴史: 元メッツォ・ネレス, now part of Valmet. The ND9000 series is a high-end double-acting, intrinsically safe HART smart valve controller for closed-loop positioning of pneumatic control valves.
- 型式コードの説明
ND9203: ND9200 series, 複動式, HART protocol smart positioner
HE: Enhanced high-precision Hall feedback module
1: Intrinsically safe Ex ia IIC T6 Ga, suitable for hazardous areas Zone 0/1
比較: ND9203HE8 is flameproof type (ゾーン 1/2), do not mix up.
- 主要な技術仕様
| アイテム | 仕様 |
| 入力信号 | 4–20mA DC, loop-powered, HART7, 外部電源は不要です |
| Actuator Compatibility | Double-acting pneumatic actuator; linear stroke 3~120mm, rotary stroke 0~95° |
| Air Supply Pressure | 0.14~0.8 MPa (1.4~8 bar), standard instrument air |
| Positioning Accuracy | ±0.1~±0.2% FS, extremely low hysteresis |
| Explosion Protection | アテックス / IECEx Ex ia IIC T6 Ga, 本質的に安全 |
| 保護クラス | IP66 / NEMA 4X |
| 動作温度 | -40℃~+85℃ (optional Arctic low-temperature version down to -53℃) |
| Valve Position Sensing | Non-contact Hall sensor, 機械的摩耗がない |
| 認証 | SIL2 (IEC61508) |
| ハウジング材質 | Anodized aluminum alloy housing with local LCD and knob operation |
| 重さ | 約. 2.8 kg |
| Air Connection | G1/4 (NPT1/4 optional); Electrical port M20×1.5 |
- 主な特長
- Automatic Calibration: One-shot auto-tuning, supports quick single-point calibration, ホットスワップ対応
- Advanced Valve Diagnostics: Valve characteristic curve, friction, 脳卒中, differential pressure and equipment temperature monitoring, イベントロギング, predictive maintenance enabled; compatible with Neles FieldCare, FDT/DTM and EDDL
- Piezo Pilot Valve: Extremely low static air consumption, energy saving and fast response
- ローカルHMI: LCD display with buttons for on-site configuration, diagnostic viewing and operation permission lockout
- Configuration for Direct/Reverse Action & 流量特性: リニア / Equal Percentage / Quick Open, カスタマイズ可能な
- Valve Position Alarm and Fault Current Setting (FDE Fault Position Output)
- 典型的なアプリケーションシナリオ

石油化学, 油 & gas refining, coal chemical, power plant and fine chemical industries; hazardous explosive areas for linear and rotary double-acting control valves (preferred match for Metso Neles control valves).
- インストール & 試運転ガイドライン
- 設置基準: Comply with VDI/VDE3845, minimize backlash of valve feedback linkage
- Air supply requirement: Dry and clean instrument air, filtration ≥5μm, oil-free and water-free
- 配線: Intrinsically safe circuit must be fitted with safety barrier; IS cable routed separately, not in the same tray as power cables
- Calibration procedure: Supply air → connect 4mA/20mA signal → start auto-tuning routine, verify dead band and hysteresis after completion
- コミュニケーション: Use HART communicator or FieldCare to read valve diagnostics and modify parameters
- Common Troubleshooting Checklist
Position oscillation: Unstable air supply, over-sensitive PID parameters or excessive actuator friction; reduce gain or increase dead band
Valve position fails to follow setpoint: Loose feedback linkage, insufficient air supply, blocked piezo pilot valve or excessive voltage drop across IS safety barrier
HART communication failure: Insufficient/excessive loop load, reversed polarity or improper shielding earthing of cable
Alarms: Valve stroke out of limit, differential pressure alarm or internal overtemperature
- 代替 / Similar Series Reference Models
ND9203HE8: 同じ性能, flameproof type, alternative to HE1 for Zone 1/2 のみ
ND9103HX: Basic HART version, standard non-enhanced feedback, 精度が若干低い
ND9206HE1: Intrinsically safe same as HE1, compatible with actuators of larger torque
コンタクタ,サーキットブレーカー,センサー,エンコーダ,PLC,コンバータ