微信: +86-13184948252 ワッツアップ: 0086-13811255435 電子メール: kent@bestcontactor.com

について 接触 |

GV3P80 Motor Circuit Breaker - コンタクタ,サーキットブレーカー,ソーラーインバーター,電気メーター,太陽電池

サーキットブレーカー/

GV3P80 Motor Circuit Breaker

GV3P80 is a 3‑pole thermal‑magnetic motor circuit breaker from Schneider Electric TeSys GV3 series. It has an adjustment current range of 70–80A, suitable for 45kW (400V) / 55kW (690V) three‑phase motors. It integrates triple protection (過負荷, short‑circuit, phase failure) and isolation function, serving as a core protection component in industrial motor circuits. Model Explanation GV3: ...

  • 製品詳細

GV3P80 is a 3‑pole thermal‑magnetic motor circuit breaker from Schneider Electric TeSys GV3 series. It has an adjustment current range of 70–80A, suitable for 45kW (400V) / 55kW (690V) three‑phase motors. It integrates triple protection (過負荷, short‑circuit, phase failure) and isolation function, serving as a core protection component in industrial motor circuits.

  1. Model Explanation

GV3: TeSys GV3 motor circuit breaker series (frame size 3)

P: Thermal‑magnetic release (triple protection: 過負荷 + short‑circuit + phase failure)

80: Rated current 80A, adjustable range 70–80A (continuously adjustable)

  1. 主な仕様 (Full Data)
アイテム仕様
3P (three‑phase)
Adjustment current range70–80A (continuously adjustable)
Trip typeThermal‑magnetic
Short‑circuit trip multiplier14×In (1120あ)
Breaking capacity Icu65kA @ 230V; 50kA @ 400V; 6kA @ 690V
Rated operational voltage Ue690V AC 50/60Hz
Insulation voltage Ui690Vと
Impulse withstand voltage Uimp6kV
Suitable motor power45kW @ 400V; 55kW @ 690V; 22kW @ 230V
端子EverLink screw terminals (25–35mm² cable)
取り付けDIN rail (width 55mm), screw mountable
Degree of protectionIP20 (front)
動作温度-20°C ~ +60°C (derating factor: 0.8 at +60°C)
Mechanical endurance50,000 operating cycles
Electrical endurance20,000 cycles (category AC‑3)
Isolation functionComplies with IEC 60947‑1, can be used as safety isolator
CertificationsCCC, CE, UL, CSA, IEC 60947‑4‑1
重さ約. 1.02 kg
寸法 (W×H×D)55 × 105 × 78 mm
  1. Core Functions & 利点
  2. Triple Protection

Thermal trip: Overload inverse‑time protection (simulates motor heating characteristics)

Magnetic trip: Short‑circuit instantaneous protection (fixed 14×In)

Phase failure protection: Automatic trip under three‑phase unbalance (IEC 60947‑4‑1)

  1. EverLink Terminal Technology

Maintenance‑free, anti‑loosening, oxidation‑resistant, suitable for large‑section cables, reduces wiring failure risks.

  1. 安全設計

Knob operation, lockable in OFF position (up to 3 padlocks)

Clear current scale for precise adjustment

Complies with IEC isolation standards, usable as motor circuit isolator

  1. Wide Environmental Adaptability

Operating altitude: ≤3000m (no derating required)

Vibration resistance: 10–150Hz, 0.5mm amplitude

Shock resistance: 5Gn (11MS); 30Gn (1MS)

  1. 選定基準 (TeSys GV3 Series)
モデルAdjustment CurrentSuitable Power (400V)Trip Type特徴
GV3P6555–65A37kWThermal‑magnetic標準, EverLink terminals
GV3P8070–80A45kWThermal‑magneticThis model, max adjustment current
GV3L8070–80A45kWMagneticShort‑circuit protection only
GV3ME8040–80A45kWThermal‑magnetic3‑step adjustment (40–50/63–80), economy version
GV3P4030–40A22kWThermal‑magneticFor small‑medium motors
  1. アプリケーション

Direct starting / star‑delta starting circuits for three‑phase asynchronous motors

Main circuit protection for fans, pumps, コンプレッサー, conveyors, machine tools

Industrial automation lines, construction equipment motor control

Motor circuits requiring isolation and safety interlock (例えば, emergency stop loops)

Motors with frequent starting/stopping and fluctuating loads

  1. Replacement Options
  2. Schneider same series

GV3L80 (short‑circuit only, lower cost)

GV3ME80 (simplified adjustment, same mounting space)

  1. Competitor alternatives

シーメンス: 3RV1041‑4JA10 (70–80A, 3P, thermal‑magnetic)

ABB: MS165‑80 (70–80A, 3P, thermal‑magnetic)

Chinese brands: Chint NM1‑125S, Delixi CDM1‑125 (motor protection curve matching required)

  1. Upgrade solution

Schneider GV4P08N (frame 4, higher breaking capacity, for motors above 55kW)

Selection Tips

  1. Select adjustment range at 1.1–1.25 × motor rated current
  2. Confirm breaking capacity meets system short‑circuit current requirements
  3. For isolation function, prefer models with certified isolation
  4. For limited wiring space, choose EverLink terminal models to reduce faults

Complete Model List of Schneider Electric TeSys GV Series Motor Circuit Breakers

Schneider TeSys GV series motor circuit breakers include six sub‑series: GV1, GV2, GV3, GV4, GV5, GV6, covering an adjustment range from 0.06A to 800A, suitable for 0.03kW to 400kW (400V) three‑phase motors, with thermal‑magnetic, magnetic, and economy thermal‑magnetic protection types.

  1. GV1 Series (Miniature, 製造中止, replaced by GV2ME)

GV1ME01: 0.1–0.16A

GV1ME02: 0.16–0.25A

GV1ME03: 0.25–0.4A

GV1ME04: 0.4–0.63A

GV1ME05: 0.63–1.0A

GV1ME06: 1.0–1.6A

GV1ME07: 1.6–2.5A

GV1ME08: 2.5–4.0A

  1. GV2 Series (Small, 0.06–16A, 0.03–15kW/400V)

2.1 GV2P (Thermal‑magnetic, full protection, knob)

モデルAdjustment CurrentSuitable Power (400V)
GV2P010.1–0.16A0.06kW
GV2P020.16–0.25A0.12kW
GV2P030.25–0.4A0.2kW
GV2P040.4–0.63A0.37kW
GV2P050.63–1.0A0.55kW
GV2P061.0–1.6A0.75kW
GV2P071.6–2.5A1.5kW
GV2P082.5–4.0A2.2kW
GV2P104.0–6.3A3kW
GV2P146.3–10A4kW
GV2P1610–16A7.5kW

2.2 GV2L (Magnetic, short‑circuit only, knob)

モデルAdjustment CurrentSuitable Power (400V)
GV2L010.1–0.16A0.06kW
GV2L020.16–0.25A0.12kW
GV2L030.25–0.4A0.2kW
GV2L040.4–0.63A0.37kW
GV2L050.63–1.0A0.55kW
GV2L061.0–1.6A0.75kW
GV2L071.6–2.5A1.5kW
GV2L082.5–4.0A2.2kW
GV2L104.0–6.3A3kW
GV2L146.3–10A4kW
GV2L1610–16A7.5kW
GV2L2014–20A11kW
GV2L2218–25A15kW

2.3 GV2ME (Economy thermal‑magnetic, pushbutton, 3‑step)

モデルAdjustment CurrentSuitable Power (400V)
GV2ME010.1–0.16A0.06kW
GV2ME020.16–0.25A0.12kW
GV2ME030.25–0.4A0.2kW
GV2ME040.4–0.63A0.37kW
GV2ME050.63–1.0A0.55kW
GV2ME061.0–1.6A0.75kW
GV2ME071.6–2.5A1.5kW
GV2ME082.5–4.0A2.2kW
GV2ME104–6.3A3kW
GV2ME146.3–10A4kW
GV2ME1610–16A7.5kW

2.4 GV2LE (Magnetic with electronic trip, special applications)

GV2LE01 ~ GV2LE22: matching current ratings as GV2L, with electronic trip

  1. GV3 Series (中くらい, 9–80A, 5.5–45kW/400V, 55mm width)

3.1 GV3P (Thermal‑magnetic, full protection, EverLink)

モデルAdjustment CurrentSuitable Power (400V)
GV3P139–13A5.5kW
GV3P1813–18A11kW
GV3P2518–25A15kW
GV3P3223–32A18.5kW
GV3P4030–40A22kW
GV3P5040–50A30kW
GV3P6555–65A37kW
GV3P7365–73A45kW
GV3P8070–80A45kW

3.2 GV3L (Magnetic, short‑circuit only)

GV3L25: 18–25A

GV3L32: 23–32A

GV3L40: 30–40A

GV3L50: 40–50A

GV3L65: 55–65A

GV3L80: 70–80A

3.3 GV3ME (Economy thermal‑magnetic, 3‑step)

モデルAdjustment CurrentSuitable Power (400V)
GV3ME4040–50A30kW
GV3ME6350–63A37kW
GV3ME8040–80A (3 steps: 40–50/63–80)45kW
  1. GV4 Series (大きい, 25–115A, 15–55kW/400V, 81mm width)

4.1 GV4P (Thermal‑magnetic, full protection)

モデルAdjustment CurrentSuitable Power (400V)
GV4P2525–32A18.5kW
GV4P4032–40A22kW
GV4P5040–50A30kW
GV4P6350–63A37kW
GV4P8063–80A45kW
GV4P10080–100A55kW
GV4P115100–115A55kW

4.2 GV4L / GV4LE (Magnetic type)

GV4L25 ~ GV4L115: matching current ratings as GV4P

GV4LE25 ~ GV4LE115: magnetic with electronic trip

4.3 Special GV4 Models

GV4PB80S: UL489 approved, 63–80A

GV4P02N: 2‑pole thermal‑magnetic, special applications

  1. GV5 / GV6 Series (Extra‑large, 100–800A, 55–400kW/400V)

GV5P100: 80–100A

GV5P125: 100–125A

GV5P160: 125–160A

GV5P200: 160–200A

GV6P250: 200–250A

GV6P315: 250–315A

GV6P400: 315–400A

GV6P500: 400–500A

GV6P630: 500–630A

GV6P800: 630–800A

 

  1. モデルの命名規則
Letter/Number意味
GVTeSys GV series motor circuit breaker
1/2/3/4/5/6Frame size (1 = smallest, 6 = largest)
PThermal‑magnetic trip (過負荷 + short‑circuit + phase failure)
LMagnetic trip (short‑circuit only)
MEEconomy thermal‑magnetic trip (3‑step, cost‑optimized)
LEMagnetic trip with electronic functions
NumberCurrent rating (例えば, 80 = 70–80A)
  1. クイックセレクションガイド
  2. Select adjustment range at 1.1–1.25 × motor rated current
  3. For full protection (過負荷 + short‑circuit + phase failure): choose P series
  4. If thermal protection exists (例えば, VFD): choose L series (short‑circuit only)
  5. Cost‑sensitive, simple adjustment: choose ME series (3‑step)
  6. Small motors (≤15kW): GV2; 中くらい (15–45kW): GV3; 大きい (≥55kW): GV4–GV6
  7. 注意事項
  8. All models are 3‑pole (3P) for three‑phase asynchronous motors
  9. Protection characteristics comply with IEC 60947‑4‑1
  10. 遮断容量: GV2/GV3 100kA@400V; GV4 65kA@400V
  11. 取り付け: 35mm standard DIN rail
  12. Degree of protection: IP20 (front operating part)

前へ:

返信を残す

伝言を残す