 INVT-CHF100A-055G-075P-4 Converter - コンタクタ,サーキットブレーカー,ソーラーインバーター,電気メーター,太陽電池

ソーラーインバーター/電気/

INVT-CHF100A-055G-075P-4 Converter

Model SegmentDescription
INVTBrand Logo of INVT
CHF100ASeries Name: Vector General-Purpose Frequency Converter (enhanced version of the CHF series, integrating the advantages of CHF100 and CHE100)
055GSuitable for standard motor power of 55kW (G = General Load)
075PSuitable for heavy-duty motor power of 75kW (P = Heavy Load)
4Suitable for three-phase 400V-class voltage (380-415Vと)

  • 製品詳細

INVT-CHF100A-055G-075P-4 INVT Vector General-Purpose Frequency Converter

  1. Model Interpretation
Model SegmentDescription
INVTBrand Logo of INVT
CHF100ASeries Name: Vector General-Purpose Frequency Converter (enhanced version of the CHF series, integrating the advantages of CHF100 and CHE100)
055GSuitable for standard motor power of 55kW (G = General Load)
075PSuitable for heavy-duty motor power of 75kW (P = Heavy Load)
4Suitable for three-phase 400V-class voltage (380-415Vと)
  1. コア技術パラメータ
  2. Basic Electrical Parameters
Parameter ItemValueRemarks
Rated Input Voltage380-415Vと, three-phase, 50/60HzVoltage fluctuation range ±15%
Rated Output Power55kW (standard load) / 75kW (heavy load)Rated value for continuous operation
Rated Output Current105あ (standard) / 135あ (heavy load)At ambient temperature of 40℃
Output Frequency Range0.00-600.00HzAccuracy ±0.01Hz
制御モードSensorless Vector Control (SVC), V/F Control, Torque ControlThree modes optional
  1. Performance Indicators
Parameter ItemValueApplicable Conditions
Starting Torque0.5Hz / 150% rated torqueIn sensorless vector control mode
Speed Regulation Accuracy0.2% rated speedIn SVC mode
Torque Response Time<20msDuring dynamic load changes
Carrier Frequency1.0-15.0kHzAdjustable according to motor noise and heating
過負荷容量150% rated current for 1 minute, 180% rated current for 10 秒For standard load; 120% rated current for 1 minute for heavy load
  1. 機械的パラメータと環境パラメータ
Parameter ItemValueStandard/Remarks
Protection ClassIP20 (main unit)IEC 60529, must be installed in control cabinet
Cooling MethodForced Air CoolingBuilt-in cooling fan, automatic derating when overheated
動作温度-10℃~+40℃For every 1℃ rise above 40℃, rated current decreases by 1%, maximum temperature 50℃
Storage Temperature-25℃~+65℃No condensation, no corrosive gas
Mounting Method壁掛け / Cabinet-mountedReserved heat dissipation space required (≥100mm top and bottom, ≥50mm left and right)

Ⅲ. 機能的な特徴

  1. Excellent Control Performance: Adopts DSP control system to realize sensorless vector control, effectively suppressing low-frequency oscillation.
  2. Comprehensive Protection Functions: Equipped with multiple protection functions such as overcurrent, overvoltage, undervoltage, overtemperature, phase loss, 過負荷, ground fault and short circuit.
  3. Rich Application Functions: Built-in PLC simple programming, multi-speed control (up to 16 speeds), PID control, frequency swing control, synchronous control, 等.
  4. Strong Communication Capability: 標準RS485インターフェース, supporting Modbus RTU protocol, expandable with PROFIBUS-DP, DeviceNet and other fieldbuses.
  5. Flexible Input and Output: 15 digital I/O channels (9DI/6DO by default), 2 analog input channels (0-10V/4-20mA), 2 analog output channels.
  6. Significant Energy-saving Effect: Functions such as Automatic Voltage Regulation (AVR), automatic current limiting, sleep and wake-up, especially suitable for energy-saving transformation of fan and pump loads.
  7. Application Scope
  8. Fans and Pumps: Boiler induced draft fans, central air conditioning fans, cooling tower fans, oilfield water injection pumps, oil transfer pumps, chemical process pumps, 等.
  9. Industrial Machinery: Air compressors, injection molding machines, extruders, printing machines, packaging machines, textile machinery, CNC machine tool spindle control.
  10. Building Materials and Metallurgy: Cement rotary kilns, ball mills, belt conveyors, hoists, auxiliary systems of steel rolling equipment.
  11. Other Fields: Mining machinery, port cranes, pharmaceutical equipment, food processing machinery, sewage treatment equipment.
  12. Selection Suggestions
  13. Load Type Matching: Select type G for standard loads (fans, pumps), and type P for heavy loads (compressors, extruders).
  14. Motor Power Adaptation: The rated power of the frequency converter should be ≥ the rated power of the motor; it is recommended to select one level higher for heavy-duty applications.
  15. Environmental Condition Consideration: Derating use or additional protective measures are required for high-temperature, high-altitude and dusty occasions.
  16. Special Function Requirements: Select models with corresponding interfaces for communication networking; select vector control mode for fast response.
  17. Accessory Selection: Optional input and output reactors, filters, braking units, operation panels (universal for CHV100 series).
  18. トラブルシューティング
Fault CodeFault CauseTroubleshooting Method
OVDC bus overvoltageCheck grid voltage, extend deceleration time, install braking unit.
UVDC bus undervoltageCheck grid voltage, shorten acceleration time, check input phase loss.
OCOutput overcurrentCheck insulation of motor and cables, reduce load, extend acceleration time.
OHFrequency converter overtemperatureCheck cooling fan, clean air duct, reduce ambient temperature.
PHInput phase lossCheck input power supply, tighten wiring terminals, replace damaged fuses.
GFGround faultCheck insulation of motor and cables, eliminate ground fault points.

Ⅶ. Installation and Wiring Key Points

  1. 設置前, confirm that the power supply voltage matches the rated voltage of the frequency converter, disconnect the power supply and verify no voltage.
  2. Adopt 35mm DIN rail mounting or wall-mounted mounting to ensure sufficient heat dissipation space.
  3. Main circuit wiring: R/L1, S/L2, T/L3 are inputs; U, V, W are outputs; PE is the grounding terminal.
  4. Control circuit wiring: Shielded wires should be used for analog input, with the shielding layer grounded at one end; digital input should avoid routing in the same slot as high-voltage electricity.
  5. Check parameter settings before power-on, especially basic parameters such as motor rated power, rated current and rated frequency.