Pilz 773400-PNOZ-MI1P Safety Input Expansion Module

Pilz 773400-PNOZ-MI1P Safety Input Expansion Module The Pilz 773400-PNOZ-MI1P is an 8-channel 24VDC safety digital input expansion module belonging to the PNOZmulti Classic product range. It provides I/O expansion for the PNOZmulti safety control system and supports safety functions such as emergency stop, safety gate monitoring and two-hand control. Complying with PLd per EN ISO ...

  • 製品詳細

Pilz 773400-PNOZ-MI1P Safety Input 拡張モジュール

キノコ 773400-PNOZ-MI1P is an 8-channel 24VDC safety digital input expansion module belonging to the PNOZmulti Classic product range. It provides I/O expansion for the PNOZmulti safety control system and supports safety functions such as emergency stop, safety gate monitoring and two-hand control. Complying with PLd per EN ISO 13849-1 and SIL CL 2 per EN/IEC 62061, it is designed for industrial automation applications requiring high-safety-level signal acquisition. この製品は販売終了しました, and corresponding modules from the PNOZmulti 2 series are recommended as replacements.

  1. モデルコードの定義
コードセグメント意味詳細な説明
773400注文コードUnique official Pilz part number for ordering and inventory management
PNOZシリーズプレフィックスCore identifier for Pilz safety relay and safety control product line
MIモジュールの種類Safety Digital Input Module (M-Series Input), differentiated from MO (出力) and MC (混合I/O)
1Channel SpecStandard 8-input variant (1 = 8 チャンネル, 2 = 16 チャンネル)
PVersion CodePNOZmulti Classic edition, distinguished from Series 2 (new-generation PNOZmulti 2)

注記: This is an expansion module for PNOZmulti Classic and must be used together with compatible base units (例えば. PNOZ m1p); standalone operation is not supported.

  1. 主要な技術仕様
カテゴリ仕様備考
基本特性
Channel Count8 safety digital input channelsConfigurable for single-channel or dual-channel safety circuit logic
入力タイプ24VDC discrete inputENに準拠 61131-2 タイプ 1; compatible with PNP / NPN sensors
Input PolarityPositive/Negative Logic configurableParameterized via PNOZmulti Configurator software
入力電流約. 5チャンネルあたりの電流Low-power design to reduce load on field sensors
電気的パラメータ
動作電圧20.4~28.8VDC (nominal 24VDC)Powered from base unit via internal backplane bus
Input Signal LevelOFF-state: -3~+5VDC; ON-state:19.2~30VDCWide voltage tolerance against field supply fluctuation
Test Pulse FunctionBuilt-in test pulse outputDetects short-circuit across input contacts to elevate safety integrity
Isolation RatingNo inter-channel isolation; isolation between module and backplaneDielectric withstand: 250Vrms
応答時間≤10ms (factory default setup)Fast safety reaction for emergency stop and safety interlock
安全認証
安全性評価ISO で 13849-1 PLd; EN/IEC 62061 SIL CL 2For medium-risk machinery safety applications
Approved CertificatesCE, UKCA, cULus, KOSHA, EAC (TÜV certified)Meets global mainstream market safety compliance
環境データ
動作温度.0℃~60℃Standard industrial ambient range
Storage Temp.-25℃~70℃Tolerates harsh transportation & storage conditions
相対湿度93%RH @40℃, 結露しないことExtended humidity resistance
侵入保護IP20For cabinet indoor installation only
機械式 & 取り付け
寸法94(H)×22.5(W)×121(D) mmStandard DIN rail footprint
重さ~120g (端子なし), ~138g (端子付き)Lightweight to minimize DIN rail load
取り付けHorizontal installation on 35×7.5mm EN 50022 standard DIN railConvenient system expansion and integration
端子の種類Optional spring-cage plug-in terminals / ネジ端子Fast field wiring and maintenance

Ⅲ. Full Product Lineup (PNOZmulti Classic Input Expansion Modules)

モデルChannel QtyInput SpecSpecial Feature注文番号.ライフサイクルステータス
PNOZ MI1P824VDC Safety DIStandard non-coated version773400製造中止
PNOZ MI1P C824VDC Safety DIConformal coated for harsh ambient773405製造中止
PNOZ MI2P1624VDC Safety DI16-channel extended model773410製造中止
PNOZ MI2P C1624VDC Safety DI16-channel coated variant773415製造中止
PNOZ MI4P424VDC Safety DICompact 4-channel type773420製造中止
  1. 交換 & ブランド間の比較
  2. Internal Pilz Alternatives
Original PNReplacement PN交換理由互換性に関する注意事項
773400-PNOZ-MI1P774700-PNOZ m2p mi1pNew upgrade to PNOZmulti 2 platformRequires PNOZmulti 2 base unit + full program reconfiguration
773400-PNOZ-MI1P774705-PNOZ m2p mi1p CCoated version for corrosive environmentRequires PNOZmulti 2 base unit + full program reconfiguration
773400-PNOZ-MI1P773405-PNOZ MI1P CConformal coating addedDrop-in compatible with original PNOZmulti Classic base unit
  1. Competitor Cross Reference
Pilz Partシーメンス相当品シュナイダー相当品オムロン相当品主要な相違点
773400-PNOZ-MI1P3RK1304-0CB00-0AA2140SAI73400G9SA-501キノコ: Built-in safety test pulse, PLd/SIL2
シーメンス: PROFIsafe fieldbus, PLd/SIL3
シュナイダー: Quantum safety I/O, PLd/SIL2
オムロン: Standalone safety relay, PLc/SIL1
  1. 応用分野 & 業界の事例
  2. 推奨されるアプリケーション シナリオ

自動車製造

Body Welding Line: Signal collection for E-stop pushbuttons, safety gate limit switches and two-hand control devices

Final Assembly Line: Connection for safety light curtains, safety mats and robot perimeter protection signals

Coating Workshop: Interlock input for explosion-proof doors and flammable gas detection alarms

工作機械 & 機械加工

CNC Machine: Safe spindle stop, tool-change safety interlock and workpiece clamping confirmation signals

Press & Bending Equipment: Mould safety gate, two-hand start button and slide stroke limit monitoring

Automated Conveying Line: Conveyor safety interlock and personnel access detection

食べ物 & 飲料 / 包装

High-speed Packaging Machine: Safety door switches, emergency stop and overload protection signals

Food Processing Line: Wash zone interlock and sterilizer safety gate status monitoring

Filling Equipment: Bottle/can in-position detection and protective door interlock

ロジスティクス & Warehouse Automation

Automated AS/RS: Stacker crane limit switches, E-stop and walk-in access detection

コンベアシステム: Line emergency stop, safety gate and overload fault input

Robotic Sorting Line: Robot cell guarding and safety light curtain signal acquisition

  1. 推奨されないアプリケーション

Standalone operation: Mandatory pairing with PNOZmulti Classic base unit; cannot run independently

High safety requirement (PL e / SIL3): Select PNOZmulti 2 or higher-grade safety modules instead

Outdoor exposed installation: IP20 rated only for cabinet mounting

AC signal input: Module exclusively for 24VDC; dedicated AC input modules required for AC field signals

  1. 代表的な応用例

Project Title: Safety Retrofit for Automotive Component Stamping Line

Bill of Material: 1×PNOZ m1p base unit + 2×PNOZ MI1P (773400) + 1×PNOZ MO1P output module + PNOZmulti Configurator

Application Benefits:

  1. Monitors 8 safety gate limits, 4 emergency stops and 2 two-hand control signals
  2. Redundant safety circuit design fulfilling EN ISO 13849-1 PLd specification
  3. Onboard test pulse automatically diagnoses input contact short-circuit to improve system reliability
  4. Integrated diagnostics cut unplanned downtime by 40% and enable rapid fault pinpointing for safety loops
  5. トラブルシューティングガイド
故障の症状Root CauseInspection StepsRemedial Action
Module dead, all LEDs off1.Base unit power failure1.Check base unit power LED1.Repair base unit power supply
2.Poor backplane connection2.Unplug and re-seat module2.Fix module locking position
3.Internal hardware damage3.Replace with spare module3.Install replacement module
Partial channels no input1.Wiring error1.Verify wiring against schematic1.Correct field wiring
2.Field sensor defective2.Measure sensor output via multimeter2.Replace faulty sensor
3.Incorrect test pulse setup3.Check test pulse parameter in Configurator3.Config test pulse (only for dry contacts)
4.Burned input channel4.Test with known-good sensor4.Swap to spare channel or replace module
Spurious safety trip1.EMI interference1.Check shielding & 接地1.Reroute cable & add shielding
2.Unstable supply voltage2.Measure input DC 19.2~30V range2.Add power filter for stable supply
3.Loose terminal wiring3.Tighten all screw terminals3.Re-terminate loose wiring
4.Test pulse cross-interference4.Adjust/disable test pulse (for active sensors only)4.Optimize test pulse configuration
Permanent fault LED ON1.Safety circuit fault1.Inspect safety loop wiring1.Remediate faulty safety wiring
2.Backplane communication loss2.Check inter-module bus connection2.Restore bus connection
3.Invalid project configuration3.Download corrected configuration3.Re-program and download project

Ⅶ. 選定ガイドライン & クイックリファレンス

選択ニーモニック

Eight-channel safety DI MI1P, 24VDC PNOZ expansion piece;

PLd safety grade, test pulse stops short-circuit disease;

自動, machine, packaging cabinet-mounted IP20 lease;

Classic discontinued, upgrade to m2p series.

Quick Rules

  1. Model Decoding:773400 = PNOZ MI1P; PNOZ=Safety Series; MI=Input; 1=8CH; P=Classic Version
  2. Core Spec Shortcut:8CH /24VDC /PLd SIL2 /Built-in Test Pulse /IP20 /DIN Rail Mount
  3. 交換ガイド:Upgrade → PNOZmulti2; Harsh environment → Coated C version; Same platform → Classic coated spare
  4. Application Filter:Safety DI + Medium risk + Cabinet installation = PNOZ MI1P applicable

VIII. 注文情報 & 付属品

Standard Part No.:773400-PNOZ-MI1P (8-channel safety input module)

Conformal Coated Variant:773405-PNOZ-MI1P C

Recommended Spare Parts:

783400: PNOZmulti Spring Terminal Kit (fits MI1P/MI2P/MO1P)

793400: PNOZmulti Screw Terminal Kit (fits MI1P/MI2P/MO1P)

779110: PNOZmulti Bus Terminator (mandatory for multi-module expansion setup)