PAXS: Strain Gauge / Load Cell input model 0000: 85–250 VAC AC power supply version DC variant: PAXS0010 (11–36 VDC) Basic Specifications Brand: Red Lion (now part of HMS Networks), Made in USA Form Factor: 1/8 DIN panel mounting (cutout size: 92×45 mm) 画面: 5-digit red LED, 0.56″ (14.2 mm), sunlight-readable; 範囲: -19999 ~ 99999 ...

  • 製品詳細

PAXS: Strain Gauge / Load Cell input model

0000: 85–250 VAC AC 電源 バージョン

DC variant: PAXS0010 (11–36 VDC)

基本仕様

ブランド: Red Lion (now part of HMS Networks), Made in USA

フォームファクター: 1/8 DIN panel mounting (cutout size: 92×45 mm)

画面: 5-digit red LED, 0.56″ (14.2 mm), sunlight-readable; 範囲: -19999 ~ 99999

入力: Strain bridge input; selectable range ±24 mV / ±240 mV; compatible with load cells, strain pressure transducers and torque sensors

電源: 85–250 VAC, 50/60 Hz, 消費電力 11 W

フロントパネルの保護: IP65

認証: UL, cUL, CE, RoHS, UKCA

HSコード: 9030337000; ECCN: EAR99; 2-年間工場保証

主な機能

  1. 16-point linearization correction for non-linear load cell calibration
  2. Front-panel keypad programming (DSP/PAR/F1/F2/RST); parameters stored in EEPROM with power-off retention
  3. まで 3 plug-and-play optional expansion cards for field upgrades:

Relay setpoint card (アラーム & control output)

Analog transmitter card (4–20mA / 0–10V)

Communication card: RS232 / RS485 Modbus, Profibus‑DP

  1. Custom engineering unit labels (kg, N, t, MPa, 等)

代表的な用途

Weight monitoring, force measurement, プレッシャー & torque monitoring; サイロの計量, 材料試験機, press-fit force monitoring.

Cross Reference for the Series

PAXS0000: AC-powered strain gauge meter (現行モデル)

PAXS0010: DC-powered strain gauge meter

PAXP0000: 4–20 mA process input meter

PAXI0000: Counter/frequency meter

PAXT0000: Thermocouple/RTD temperature meter

スペアパーツ & 代替案

Optional add-on cards: PAXCDS10, PAXCDC500, PAXCDL10, 等.

アップグレード交換: New-generation PAX2S0000 (PAX2 series, dual-line color display with enhanced functions)

PAXS0000 Red Lion | On-Site Calibration with Standard Weights + Signal Source ADC Calibration + Fault Troubleshooting Checklist

前提条件: 30-minute power warm-up; confirm PCB jumpers: input range (±24 mV / ±240 mV), excitation voltage (5 V / 10 V); complete sensor wiring (EXC+, EXC-, SIG+, SIG-, shield); parameter lock released (unlock first if locked)

キーパッドの機能:

DSP = Back / Display Toggle | PAR = Confirm / Next Item | F1 = Up | F2 = Down | RST = Zero Reset

  1. Two-Point Field Calibration with Standard Weights (Recommended for Weighing & Force Measurement)

This is Scaling (スパン & Zero Calibration), NOT internal ADC factory calibration.

9-FCS is ADC reference calibration, factory-set only; only re-calibrate after meter drift or mainboard replacement (access with CODE 48). Do NOT run this step for regular on-site weighing.

  1. Zero load: Ensure no weight on the platform, no mechanical binding; connect shield with single-point grounding; wait for stable reading.
  2. Press PAR repeatedly to enter the menu, open the INP input module, configure:

入力範囲 (24 mV / 240 mV), excitation voltage, decimal point, engineering unit

  1. Open the SCAL scaling menu

ゼロ (ZERO): 無負荷, press PAR to confirm zero; 待ってください —- and save the zero offset

スパン (SPAN): Apply standard weights (≥70% full scale). Once stable, edit the displayed value to match the actual weight of the test weights, then press PAR to save span gain.

  1. Exit the SCAL menu; repeat zero-load and full-load testing 2~3 times. Re-calibrate if deviation is large.
  2. オプション: LIN 16-point linearization calibration (for non-linear load cells or high-precision press-fit curve testing; input load and corresponding reading point by point)
  3. After calibration, set a security password to lock parameters against accidental changes.
  4. Internal ADC Reference Calibration (9-FCS, CODE = 48, Service Use Only)

Only perform this if the meter drifts, mainboard is replaced, or ADC reading is suspected inaccurate. Skip this step for normal field weighing.

  1. Enter menu 9-FCS, enter password 48, press PAR to confirm.
  2. Select the active input range (±24 mV or ±240 mV).
  3. Zero point: Set signal source output to 0 mV across SIG+ and SIG-, press PAR and wait for —-.
  4. Full-scale point: Output the corresponding full-scale signal (20 mV for 24 mV range / 200 mV for 240 mV range; do not exceed full range). Press PAR and wait approx. 10 秒.
  5. When NO appears, press PAR twice consecutively to exit the menu.
  6. Reconnect the load cell, then re-run the weight-based SCAL scaling calibration above.
  7. Restore Factory Defaults

Locate the dEF menu and confirm the reset.

⚠️ All calibration data, alarm settings and communication parameters will be erased; full re-calibration is mandatory after reset.

  1. Fault Troubleshooting Checklist (PAXS0000)
  2. 表示なし

供給電圧を確認してください: 85–250 VAC; verify terminal voltage, live/neutral polarity and loose terminals

Check internal fuse on the meter

Distinguish from parameter lock (LOC): LOC only blocks parameter editing, not power-up display

Faulty power board; replace the meter

  1. LOC Locked, Cannot Enter Menu or Edit Parameters

Parameter security lock enabled; enter the unlock password

If password is lost: restore factory defaults (all calibration data will be lost)

  1. OL / UL Alarm (OL = Over Range; UL = Under Range)

Load cell overloaded, impacted, or load exceeds full scale

Broken excitation wire, open SIG+/SIGwire, open bridge circuit inside the load cell

Incorrect jumper selection (240 mV range selected while signal is only 24 mV, またはその逆)

Short-circuit of load cell or damaged signal cable shorted to ground

Span value set too small during scaling

  1. Unstable Reading, Jitter & Drift (High-Frequency Fluctuation)

Shield wire missing; multi-point grounding; signal cable routed alongside power cables causing EMI interference

Oxidized or loose wiring terminals

Unstable excitation voltage; load cell creep or cell damage

Filter parameter FLT set too low (速い応答); increase filter time

Mechanical binding on the weighing platform, tight limit stops, loose base mounting

Water ingress or dampness inside junction box

  1. ゼロドリフト, Cannot Zero with No Load, Permanent Zero Offset

Auto zero tracking ZTRK disabled; enable zero tracking (do not set large tracking values for heavy force measurement, which will cancel out real load readings)

Uneven mounting or eccentric loading on the load cell

Moisture inside junction box causing unbalanced bridge resistance

Cold calibration without sufficient warm-up (温度ドリフト)

Fatigue damage of the load cell

  1. Incorrect Readings After Loading, Poor Linear Performance, Drift After Calibration

Calibration performed with insufficient test weight (未満 70% FS), amplifying scaling error

Non-linear load cell; enable 16-point LIN linearization correction

Wrong excitation jumper (5 V / 10 V mismatch), leading to mV/V conversion error

Excessive cable resistance from long wiring without 6-wire remote sense compensation

Drifted bridge resistance due to damaged load cell

Interference from faulty expansion cards (transmitter / コミュニケーションカード)

  1. Relay Output Card (PAXCDS10) Fails to Trigger

Incorrect setpoint (SP) and hysteresis (HYST) 構成

Wrong NO/NC output mode setting

Poor card contact; 電源を切る, remove and re-seat the expansion card, clean the slot contacts

Load voltage exceeds relay contact rating

  1. Inaccurate 4–20 mA Analog Output (PAXCDC500 Transmitter Card)

Analog zero & span must be calibrated separately, independent of weighing scaling; perform dedicated AO calibration

Loop load resistance exceeds max. 750 おお; open circuit in current loop

Damaged analog output card; replace the card

  1. Modbus RS485 Communication Failure (PAXCDL10 Card)

Mismatched address, ボーレート, parity and slave ID between meter and PLC

終端抵抗がありません; A/B signal wires reversed

Meter parameter locked; locked versions switch communication to read-only mode

Cross-check Modbus register addresses against the official manual

  1. Error Codes Err1 ~ Err4

Err1: ADC input fault → Run 9-FCS CODE48 reference calibration first; failure indicates mainboard hardware damage

Err2: Expansion card communication fault → Remove cards one by one and test individually; clean slot contacts

Err3: EEPROM memory checksum failure → Parameter corruption; restore factory defaults and re-program all settings

Err4: External digital input short-circuited

  1. Standard On-Site Troubleshooting Sequence
  2. 電源を切る; inspect all wiring, shielding and measure bridge resistance across EXC and SIG terminals with a multimeter
  3. Power on and warm up for 30 分; check zero-load reading
  4. Verify jumper settings (excitation voltage & input range)
  5. Check filter and zero-tracking parameters
  6. Re-run two-point SCAL weight calibration
  7. 障害が続く場合, perform 9-FCS ADC reference calibration
  8. If calibration still fails: replace load cell or swap the meter for testing

重要な注意事項

Red Lion USA does not manufacture load cells. PAXS series meters only accept external strain bridge sensor signals. There are no original Red Lion load cell models.

  1. Red Lion Strain Gauge Meter Product List (PAXS Compatible Models)

PAX Series (1/8 DIN Panel Meters)

  1. PAXS0000: AC-powered strain gauge meter (現在のモデル), 85–250 VAC
  2. PAXS0010: DC-powered strain gauge meter, 11–36 VDC
  3. PAX2S0000: New PAX2 color display model (replaces legacy PAXS)

LD Large-Display Strain Meters (Long-Distance Viewing)

  1. LD2SG5P0: 2.25″ digit strain gauge input
  2. LD4SG5P0: 4″ digit strain gauge input

FlexEdge DA Strain Input Modules (DA70/DA75 Controller Expansion)

  1. DAM00PDSG2RA0000: Dual-channel strain input module with relay output, for weight, force and pressure bridge sensors

Obsolete Discontinued Models

  1. IMS03162: Older strain panel meter (寿命の終わり)
  2. Compatible Load Cell Models (Directly Matched with PAXS0000)

All listed models are mV/V strain bridge type, 350 Ω nominal bridge resistance, 2.0 mV/V nominal sensitivity, 4-ワイヤー / 6-wire connection, と互換性があります 5 V / 10 V excitation from the PAXS meter.

  1. メトラー・トレド

SBC Cantilever (hopper & platform scale)

MT1041 Single-point (small bench scale)

MT1240 Single-point

SB Cantilever

0745 Column Load Cell

TSH Tension Load Cell

  1. Celtron (ビシェイ)

LSD Single-point

SQB Cantilever

STC S-type Tension/Compression (widely used for press-fit force testing)

HBB Cantilever

  1. ゼミック

H3F Single-point bench scale

B3G S-type Tension/Compression

HM8 Column Load Cell

L6E Single-point

  1. HBM (ドイツ)

S40 S-type Tension/Compression

Z6FC3 Single-point Bench Scale

C16A High-capacity Column Cell for Silo Weighing

  1. Transcell

BSS S-type Tension/Compression

FSSB Single-point

CBS Cantilever

  1. 費用対効果の高い国内代替品

Bengbu Load Cells: S-type, cantilever, column, spoke type

Ningbo Keliu: SQB, BSS, DBS, PST series

Ⅲ. Mandatory Selection Criteria for PAXS0000 Load Cells (Avoid Calibration Errors)

  1. 信号の種類: mV/V strain bridge only; 4–20 mA transmitters require PAXP meter instead
  2. Bridge Resistance: 好ましい 350 おお; 120 Ω is also supported but limits parallel cell quantity
  3. 感度: 標準 2.0 mV/V; 1 mV/V or 3 mV/V can be set directly in meter scaling
  4. Excitation Voltage: Match meter jumper (5 V / 10 V) with the cell rated excitation
  5. 配線: 6-wire remote sense recommended for long cable runs (zero drift suppression); 4-wire acceptable for short distances
  6. Full-Scale Output: Ensure full-scale mV output falls within meter range (±24 mV / ±240 mV)

例: 2 mV/V cell + 10 V excitation = 20 mV full output → select ±24 mV range (most common setup)

  1. Recommended Application Combinations (Field-Proven Solutions)
  2. Press-fit & force-testing fixtures: S-type cell (STC / B3G / S40) + PAXS0000 + PAXCDS10 relay card
  3. Small bench checkweigher: Single-point cell (L6E / MT1041) + PAXS0000
  4. Hopper & サイロの計量: Cantilever SQB / column cell + PAXS0000; calculate total bridge resistance for multiple parallel cells