パラメータSpecification
定格動作電流400あ (AC-3 Duty Cycle, ≤55°C)
定格絶縁電圧690V AC 50/60Hz
Conventional Heating Current500あ (≤40°C)
Control Coil VoltageMultiple options available: 110V/220V/380V/415V AC 50/60Hz
Main Contact ConfigurationStandard type: 3P (3 Normally Open/3NO); 4P (4 Normally Open/4NO) version also available (LC1E40004 series)
Maximum Operating Frequency2400 時間あたりの操作数 (≤55°C)
機械的寿命4 100万操作
電気的寿命AC-3 Duty Cycle: ≥100,000 operations
Protection Degree (IP Rating)IP00 (No Protection) or IP20 (Finger-proof Protection)
Applicable Ambient Temperature5~55°C; Storage Temperature: -60~80°C
重さApproximately 9.1kg
寸法 (Width × Height × Depth)213×375×219mm

  • 製品詳細

Schneider LC1E400 is a 400A high-current ACコンタクタ belonging to the EasyPact TVS series. Specifically designed for industrial applications, it is used to control electric motors, lighting equipment, and other high-power loads.

Core Parameters

パラメータSpecification
定格動作電流400あ (AC-3 Duty Cycle, ≤55°C)
定格絶縁電圧690V AC 50/60Hz
Conventional Heating Current500あ (≤40°C)
Control Coil VoltageMultiple options available: 110V/220V/380V/415V AC 50/60Hz
Main Contact ConfigurationStandard type: 3P (3 Normally Open/3NO); 4P (4 Normally Open/4NO) version also available (LC1E40004 series)
Maximum Operating Frequency2400 時間あたりの操作数 (≤55°C)
機械的寿命4 100万操作
電気的寿命AC-3 Duty Cycle: ≥100,000 operations
Protection Degree (IP Rating)IP00 (No Protection) or IP20 (Finger-proof Protection)
Applicable Ambient Temperature5~55°C; Storage Temperature: -60~80°C
重さApproximately 9.1kg
寸法 (Width × Height × Depth)213×375×219mm

Duty Cycles and Applications

Main Duty Cycles:

– AC-3: Used for starting and stopping squirrel-cage motors, which is the most common industrial application.

AC-1: Used for controlling non-inductive or slightly inductive loads, such as resistance heating equipment.

典型的なアプリケーションシナリオ:

Motor control systems (power range: 220kW@415V to 280kW@690V)

Control of AC loads with a power factor ≥0.95

Industrial automation equipment

Master switch control for lighting systems

Other industrial applications requiring high-current switching

Technical Features

Performance Advantages:

High making and breaking capacity: Capable of withstanding a making current of 4000A and a breaking current of 3200A (440Vと)

Short-time withstand current: 3600あ (≤40°C, 10 秒), enhancing system reliability

Wide voltage operating range: The control coil operates stably within 85%~110% of the rated voltage, does not actuate below 70%, and releases reliably within 35%~50%

Low power consumption design: Only 15VA required in the holding state, reducing energy consumption

High anti-interference capability: Withstands 8kV impulse voltage, 過酷な産業環境に適しています

Structural Features:

Two installation methods: base mounting or DIN rail mounting, facilitating on-site deployment

Main circuit wiring: Can connect 2×150mm² cables or 30×5mm copper busbars, with a tightening torque of 35N·m

Control circuit: Bolt-fastened terminals, capable of connecting 1~4mm² wires, with a torque of 1.2N·m

– モジュラー設計, allowing addition of accessories such as auxiliary contacts and overload protection

Model Coding Explanation

LC1E400X7:

LC1: Standard prefix for Schneider contactors

– E: EasyPact TVS series

– 400: Rated current of 400A

– ×: Coil voltage code

– F: 110V AC 50/60Hz

M: 220V AC 50/60Hz

Q: 380V AC 50/60Hz

– N: 415V AC 50/60Hz

– 7: Suffix, indicating standard type (50/60Hz)

注記: The LC1E40004 series is a 4-pole version (4いいえ) with a rated current of 60A (AC-1), mainly used in special control circuits.

Application Recommendations

1. -Selection Key Points: Choose the appropriate duty cycle based on the load type (AC-3 for motor control, AC-1 for resistive loads)

2. Environmental Considerations: The installation location should be well-ventilated, with an ambient temperature not exceeding 55°C

3. Supporting Protection: It is recommended to use it with appropriate overload protection devices (such as thermal relays) to protect the motor and the contactor itself

4. Cable Selection: For the main circuit, select cables with sufficient cross-sectional area (≥150mm²) to ensure low-impedance connection

5. Maintenance Cycle: Regularly inspect the contact status; a comprehensive inspection and cleaning at least once a year is recommended

まとめ

The Schneider LC1E400 is a reliable and efficient industrial-grade contactor. With its 400A high-current handling capacity and robust design, it has become an ideal choice for motor control and high-power load management in various industrial applications. For more detailed technical parameters or special application solutions, it is recommended to refer to the official Schneider Electric manual or

パラメータSpecification
定格動作電流400あ (AC-3 Duty Cycle, ≤55°C)
定格絶縁電圧690V AC 50/60Hz
Conventional Heating Current500あ (≤40°C)
Control Coil VoltageMultiple options available: 110V/220V/380V/415V AC 50/60Hz
Main Contact ConfigurationStandard type: 3P (3 Normally Open/3NO); 4P (4 Normally Open/4NO) version also available (LC1E40004 series)
Maximum Operating Frequency2400 時間あたりの操作数 (≤55°C)
機械的寿命4 100万操作
電気的寿命AC-3 Duty Cycle: ≥100,000 operations
Protection Degree (IP Rating)IP00 (No Protection) or IP20 (Finger-proof Protection)
Applicable Ambient Temperature5~55°C; Storage Temperature: -60~80°C
重さApproximately 9.1kg
寸法 (Width × Height × Depth)213×375×219mm