シュナイダー LV429413

(MN Type 125VDC Undervoltage Release)

Schneider LV429413 is an MN series undervoltage release specially designed for molded case circuit breakers of the Compact NSX, PowerPact Multistandard, and EasyPact CVS series. It has a rated voltage of 125VDC and uses screwless spring terminals. It is used for emergency stop or remote tripping control. When the control voltage drops below 35% 定格値の, it automatically trips the circuit breaker to ensure system safety.

  1. Model Code Interpretation
コードセグメント意味
LVPrefix for Schneider low-voltage power distribution products
4294Product category identifier for undervoltage releases
13Specific specification code corresponding to 125VDC rating, MN type, screwless terminals
ミネソタ州Product type code: 不足電圧解除; MX denotes Shunt Trip

コア機能: 125VDC operating voltage, suitable for 100-630A molded case circuit breakers, non-delay type, tripping threshold at 35% 定格電圧の.

  1. コア技術パラメータ
アイテム仕様
製品タイプMN Type Undervoltage Release
Rated Control Voltage125VDC (not for AC systems)
Tripping Threshold 35% 定格電圧の (約. 43.75VDC)
Reset Voltage≥ 85% 定格電圧の (約. 106.25VDC)
端子の種類Screwless Spring Terminal
Compatible Breaker SeriesCompact NSX 100–630A, PowerPact Multistandard, EasyPact CVS
Mounting LocationAccessory slot on front of circuit breaker
Wire Capacity1.5–2.5mm² cable
Ingress ProtectionIP20 (when installed)
動作温度-25℃~+70℃
重さ約. 50g
認証IEC 60947-2, UL 489, CSA C22.2 No. 5
  1. Application Environment
  2. System Types

Industrial automation control systems, data center UPS systems

DC power supply systems, emergency stop circuits

Remote monitoring and tripping applications

  1. Operating Conditions

Control voltage fluctuation: 85%-110% of rated value for stable operation

EMC performance: IEC準拠 61000-4

Compatible frame sizes: 100あ, 160あ, 250あ, 400あ, 630あ (NSX series)

  1. インストール要件

Must be installed in dedicated front accessory slot with reliable mechanical interlock

Control circuit to be protected by 1A fuse to prevent coil damage from short circuit

Observe polarity: “+” for positive, “-” for negative

  1. Cross-Reference & 代替モデル
Replacement Typeモデルブランド説明
直接交換LV429414シュナイダー220VAC version for AC control circuits
Equivalent FunctionS29413シュナイダー (Square D)125VDC undervoltage release for PowerPact series
Cross鈥態rand AlternativeABB TA250-125DCABB125VDC undervoltage release for Tmax MCCBs
Domestic AlternativeCHINT NXB-MN/125DCチントFor NXB series MCCBs
  1. 公式注文情報
アイテム詳細
Official ModelLV429413 (global part number)
製品名Undervoltage Release MN, Compact NSX, 125VDC, Screwless Terminal
Order NoteMust match corresponding breaker model, 例えば, NSX100N, NSX250F
PackingIndividual package including release body, manual, mounting screws
EAN Code3606480019029
MOQ1 piece
  1. Engineering Implementation
  2. 互換性チェック

Confirm breaker model: only for Compact NSX (100-630あ), PowerPact Multistandard, EasyPact CVS

Verify control voltage: strictly 125VDC, not for AC or other DC voltages

Ensure front slot available for MN/MX accessories

  1. インストール手順
  2. Disconnect main and control power to the breaker
  3. Remove front accessory cover
  4. Insert undervoltage release into slot and engage mechanical interlock
  5. Secure with supplied screws
  6. Wire 125VDC with correct polarity
  7. Refit cover and perform functional test
  8. Commissioning

Trip test: reduce voltage below 43VDC; breaker must trip automatically

Reset test: restore voltage above 106VDC; breaker should close normally

Interlock check: breaker cannot be manually closed when release is activated until voltage recovers

  1. Complete Model List (MN Series Undervoltage Releases)
モデル定格電圧端子の種類Compatible Series備考
LV42940024VAC/DCScrew TerminalNSX/CVS標準
LV42940148VAC/DCScrew TerminalNSX/CVS標準
LV429402110VAC/DCScrew TerminalNSX/CVS標準
LV429403220VAC/DCScrew TerminalNSX/CVS標準
LV42941024VDCScrewless TerminalNSX/CVSSpring Terminal
LV42941148VDCScrewless TerminalNSX/CVSSpring Terminal
LV429412110VDCScrewless TerminalNSX/CVSSpring Terminal
LV429413125VDCScrewless TerminalNSX/CVSSpring Terminal
LV429414220VACScrewless TerminalNSX/CVSSpring Terminal
LV429415230VACScrewless TerminalNSX/CVSSpring Terminal
  1. Risks & Warnings
  2. 電圧マッチング: This model is only for 125VDC control circuits. Applying AC or incorrect DC voltage will burn the coil and damage the unit.
  3. Polarity: DC polarity must be observed; reversed connection causes failure or circuit damage.
  4. Overcurrent Protection: Install 1A fast-acting fuse in control circuit to protect coil.
  5. 機械的インターロック: Ensure reliable engagement; さもないと, false tripping or failure to trip may occur.
  6. Ambient Limits: Do not use above +70°C or below -25°C to avoid performance degradation.
  7. メンテナンス: Regularly check control voltage stability (85%-110% of rated) to prevent excessive mechanical wear from frequent undervoltage tripping.