Schneider iC65N is a standard miniature circuit breaker in the Acti9 series, with a breaking capacity of 6 그만큼, complying with IEC 60898-1/GB 10963.1 표준. It is suitable for power distribution protection in residential, 광고, and light industrial applications.

  1. Model Naming Rules

iC65N [Number of Poles] [Tripping Curve] [정격전류]

iC65N: Basic model (6 kA breaking capacity)

Number of Poles: 1피, 1P+N, 2피, 3피, 3P+N, 4피

Tripping Curve: B (3-5In), 기음 (5-10In), 디 (10-14In)

정격전류: 1에이, 2에이, 3에이, 4에이, 6에이, 10에이, 16에이, 20에이, 25에이, 32에이, 40에이, 50에이, 63에이

Order Code Example: A9F18106 = iC65N 1P C6A

  1. Complete Model Classification
  2. Classification by Number of Poles

1피 (Single Pole)

Tripping Curve정격전류모델Order Code
Curve B1에이, 2에이, 3에이, 4에이, 6에이, 10에이, 16에이, 20에이, 25에이, 32에이, 40에이, 50에이, 63에이iC65N 1P B[In]A9F181B[In]
Curve C1에이, 2에이, 3에이, 4에이, 6에이, 10에이, 16에이, 20에이, 25에이, 32에이, 40에이, 50에이, 63에이iC65N 1P C[In]A9F181C[In]
Curve D10에이, 16에이, 20에이, 25에이, 32에이, 40에이, 50에이, 63에이iC65N 1P D[In]A9F191D[In]

1P+N (Single Pole + Neutral)

Tripping Curve정격전류모델Order Code
Curve C1에이, 2에이, 3에이, 4에이, 6에이, 10에이, 16에이, 20에이, 25에이, 32에이, 40에이, 50에이, 63에이iC65N 1P+N C[In]A9F185C[In]
Curve D10에이, 16에이, 20에이, 25에이, 32에이, 40에이, 50에이, 63에이iC65N 1P+N D[In]A9F195D[In]

2피 (Two Poles)

Tripping Curve정격전류모델Order Code
Curve B1에이, 2에이, 3에이, 4에이, 6에이, 10에이, 16에이, 20에이, 25에이, 32에이, 40에이, 50에이, 63에이iC65N 2P B[In]A9F182B[In]
Curve C1에이, 2에이, 3에이, 4에이, 6에이, 10에이, 16에이, 20에이, 25에이, 32에이, 40에이, 50에이, 63에이iC65N 2P C[In]A9F182C[In]
Curve D10에이, 16에이, 20에이, 25에이, 32에이, 40에이, 50에이, 63에이iC65N 2P D[In]A9F192D[In]

3피 (Three Poles)

Tripping Curve정격전류모델Order Code
Curve B1에이, 2에이, 3에이, 4에이, 6에이, 10에이, 16에이, 20에이, 25에이, 32에이, 40에이, 50에이, 63에이iC65N 3P B[In]A9F183B[In]
Curve C1에이, 2에이, 3에이, 4에이, 6에이, 10에이, 16에이, 20에이, 25에이, 32에이, 40에이, 50에이, 63에이iC65N 3P C[In]A9F183C[In]
Curve D10에이, 16에이, 20에이, 25에이, 32에이, 40에이, 50에이, 63에이iC65N 3P D[In]A9F193D[In]

3P+N (Three Poles + Neutral)

Tripping Curve정격전류모델Order Code
Curve C1에이, 2에이, 3에이, 4에이, 6에이, 10에이, 16에이, 20에이, 25에이, 32에이, 40에이, 50에이, 63에이iC65N 3P+N C[In]A9F187C[In]
Curve D10에이, 16에이, 20에이, 25에이, 32에이, 40에이, 50에이, 63에이iC65N 3P+N D[In]A9F197D[In]

4피 (Four Poles)

Tripping Curve정격전류모델Order Code
Curve B1에이, 2에이, 3에이, 4에이, 6에이, 10에이, 16에이, 20에이, 25에이, 32에이, 40에이, 50에이, 63에이iC65N 4P B[In]A9F184B[In]
Curve C1에이, 2에이, 3에이, 4에이, 6에이, 10에이, 16에이, 20에이, 25에이, 32에이, 40에이, 50에이, 63에이iC65N 4P C[In]A9F184C[In]
Curve D10에이, 16에이, 20에이, 25에이, 32에이, 40에이, 50에이, 63에이iC65N 4P D[In]A9F194D[In]
  1. Series Features & Selection Guide
  2. 핵심 기술 매개변수

정격전압: 1P AC 230 다섯, 2P/3P/4P AC 400 다섯

정격 절연 전압: 600 다섯

차단 용량: 6 그만큼 (exclusive to iC65N series)

Tripping Characteristics: Three curves B/C/D for different load types

Curve B: For resistive loads (예를 들어, 조명)

Curve C: For general power distribution and motor control (most common)

Curve D: For high inductive loads and transformer protection

Protection Degree: IP40 (front), IP20 (터미널)

주변 온도: -35℃ ~ +70℃

  1. 응용 시나리오

Power distribution protection for residential and commercial buildings

Control circuits for small industrial equipment

Protection for lighting, 에어컨, 물 펌프, 등.

Replacement of traditional fuses, providing both overload and short‑circuit protection

  1. Series Comparison (iC65 Family)
시리즈차단 용량ApplicationOrder Code Prefix
iC65N6 그만큼Standard applications, cost‑effectiveA9F18/A9F19
iC65H10 그만큼Industrial environments, higher breaking requirementsA9I28/A9I29
iC65L15 그만큼Special industrial applications, high short‑circuit riskA9L28/A9L29
  1. Common Model Examples
모델Order CodeMain Application
iC65N 1P C16AA9F18116Residential lighting circuit protection
iC65N 2P C20AA9F18220Small air conditioner / water heater protection
iC65N 3P C32AA9F18332Three‑phase motor control circuit
iC65N 4P D50AA9F19450Primary protection for small transformers
iC65N 1P+N C25AA9F18525Commercial lighting system protection

The Schneider iC65N series covers all pole configurations from 1P to 4P, full current ratings from 1A to 63A, and is equipped with B/C/D tripping curves, meeting most low‑voltage power distribution protection requirements.

Select the appropriate model based on load type, 극 요구 사항, and short‑circuit breaking capacity. Curve C is preferred for standard applications.