Standard logic CPU, without CIP motion axes, part of the CompactLogix 5370 시리즈, lifecycle status: 활동적인 성숙한 (mature and available for sale)
핵심사양
User Memory: 2 MB
포트: Dual Ethernet ports supporting DLR Device Level Ring (이더넷/IP) + USB debug port
Maximum EtherNet/IP Nodes: 32 노드
Local Expansion: 최대 16 pcs of 1769-series I/O modules (backplane expansion)
SD 카드: 1 GB supplied as standard, max support 2 GB; used for firmware, program backup and log storage
Tasks: 최대 32 tasks, 최대 100 routines per task
전원공급장치: 24 VDC (powered by 1769 backplane power supply; the CPU itself has no power supply)
치수: 깊이 105 mm, 기준 1769 backplane mounting
프로그래밍 소프트웨어: 스튜디오5000 (Logix 디자이너)
문서 참조: User Manual 1769-UM021, Technical Data Sheet 1769-TD005
📌 Suffix Variations (자주 혼동되는 모델)
1769-L33ER: Standard logic CPU, no CIP motion axes (이 모델)
1769-L33ERM: 같은 2 MB 메모리, 8-axis CIP motion supported with kinematics
1769-L33ERMK: L33ERM version with conformal coating
1769-L33ERMS: GuardLogix safety CPU (2 MB standard memory + 1 MB safety memory, safety PLC), planned for obsolescence
📎 Selection & 교체 옵션
Upgrade within the same series: 1769-L36ERM (3 MB, 48 EtherNet/IP nodes, 16 모션 축)
Next-generation upgrade: 5069-L330ER (CompactLogix 5380, higher hardware performance, program portable, backplane I/O incompatible)
하향 대안: 1769-L30ER (1 MB 메모리, 16 EtherNet/IP nodes)
⚙️ Typical Application Scenarios
Medium and small production lines, 컨베이어 라인, 포장, 공조, water treatment and general equipment logic control. Ideal for projects requiring EtherNet/IP ring network, distributed remote I/O and no CIP servo motion control.
⚠️ 일반 사항 & 일반적인 결함
- The battery only maintains the real-time clock. Programs and tags are stored in flash memory and SD card. A dead battery will not cause program loss, only the system time will be lost.
- Power loss while in RUN mode triggers fault code 01 upon power-up (fault for power interruption in RUN state). This alarm can be suppressed in 제어 장치 fault settings.
- Incorrect DLR ring wiring leads to intermittent network drops. The dual Ethernet ports are dedicated DLR ring ports and cannot function as a regular network switch.
- Firmware version must match the Studio5000 version. Direct download is not allowed across major firmware revisions; use ControlFlash for firmware flashing.
Communication Protocol List for 1769-L33ER (On-board Native + Backplane Expansion Modules)
중요한: No serial port, DeviceNet or ControlNet port built into the CPU hardware. Only dual EtherNet/IP ports + USB debug port are available.
On-board Dual Ethernet Ports (Native, Firmware-enabled)
- 이더넷/IP (CIP) [기본 프로토콜]
Supports DLR Device Level Ring, star and linear topologies; CIP explicit messages, CIP I/O and CIP messaging
Limited to a maximum of 32 EtherNet/IP I/O connections
⚠️ 1769-L33ER does not support CIP Motion; select L33ERM for CIP motion control
- TCP/IP, UDP, Raw Socket
- 모드버스 TCP (via native Logix MSG instruction; no extra gateway module required)
- HTTP (내장 웹 서버, firmware dependent)
- PTP (IEEE1588 Ethernet time synchronization), DHCP
- OPC UA 서버: Supported on firmware revision V33 and newer
On-board USB Port (디버그 & Download Only, Not for Production Communication)
Only used for Studio5000 program upload/download, firmware flashing and troubleshooting. Not available for communication with external field devices.
Protocols Realized via 1769 Backplane Communication Modules (Not Native to CPU)
1769-SDN → DeviceNet (CIP DeviceNet)
1769-ASCII → DF1, 모드버스 RTU, ASCII, custom serial protocols (RS232/485)
1769-CRN → ControlNet
1769-PB4 → Profibus-DP
1769-ECR: EtherNet/IP repeater/ring terminator (not a protocol converter)
❌ Common Pitfalls
- 모드버스 RTU, DF1, DeviceNet and Profibus are not available natively. Corresponding backplane modules must be added.
- Modbus TCP is implemented by Logix MSG instructions rather than a dedicated hardware gateway. Concurrent polling load must be managed inside the PLC program.
- Communication with SCADA/HMI hosts: RSLinx Classic/RSLinx Enterprise over EtherNet/IP CIP.
Complete Configuration Procedure for 1769-L33ER Communication Parameters
Required Software: Studio5000 Logix Designer + RSLinx Classic; Dual Ethernet ports are dedicated DLR ring ports; USB is for commissioning only. No built-in serial port.
공장 기본값: BOOTP/DHCP mode, no static IP assigned.
- IP Address Assignment (4 Common Methods; BOOTP/RSLinx Preferred)
방법 1: BOOTP/DHCP Server Tool (For brand-new PLC without IP)
- Connect PC directly to the L33ER Ethernet port, disable PC firewall and set PC NIC to the same subnet.
- Launch Rockwell BOOTP-DHCP Server.
- Locate the PLC MAC address in Request History (MAC printed on the front label of the controller).
- Add to Relation List and fill in IP address, subnet mask, 게이트웨이 (선택 과목).
- Check Disable DHCP (비판적인, otherwise the PLC reverts to DHCP after power cycle) → OK, IP is written into the controller.
- Power cycle the PLC for static IP to take effect permanently.
방법 2: RSLinx Classic (Modify IP after connecting via USB or Ethernet)
- Open RSLinx → Communications → RSWho.
- Locate 1769-L33ER under USB or EtherNet/IP driver.
- Right-click the module → Module Configuration → Port Configuration.
- Change Network Configuration Type to Static, fill in IP, subnet mask and gateway.
- Apply settings; reboot the controller if prompted.
방법 3: Online modification inside Studio5000 (PLC already reachable)
- Right-click the controller in project tree → Properties.
- Navigate to Port Configuration.
- Edit static IP, subnet mask and gateway. Ethernet speed/duplex can also be configured (auto-negotiation recommended; forcing full duplex requires reboot).
- Download settings to controller and reboot for changes to apply.
방법 4: SD Card IP Configuration (Bulk Deployment)
Prepare an SD card with network configuration file. Insert the SD card and power on the PLC; IP settings load automatically, suitable for mass identical devices.
팁: IP can also be entered directly via the front-panel LCD menu of L33ER.
- EtherNet/IP I/O Configuration in Studio5000 (For Remote EIP Slaves & 분산 I/O)
- Create a new project and select 1769-L33ER with matching firmware revision.
- Project Tree: I/O Configuration → Right-click EtherNet/IP → New Module.
- Select the target EtherNet/IP slave (1734-AENTR, 가변 주파수 드라이브, third-party EIP device) and input slave IP.
- RPI (Request Packet Interval): Refresh cycle. 20~100 ms is typical for standard I/O; reduce for high-speed devices with caution to avoid bandwidth overload.
- Connection tab: Unicast/Multicast; keep default topology for DLR ring.
- Download to PLC and check online status: Green = communication healthy; Red = connection timeout, IP 충돌, undersized RPI or firmware mismatch.
Limit: L33ER supports max 32 EtherNet/IP I/O nodes. Exceeding this triggers connection resource faults.
III. DLR Device Level Ring Configuration (Dual-port Ring Redundancy)
- Daisy-chain the ports to close the ring (Port A ↔ Port B of next device).
- Controller Properties → Ethernet Port → Enable DLR. Default role is DLR Node (DLR Supervisor is usually assigned to managed switches such as 1783-ETAP).
- Single cable break triggers automatic network reconfiguration without production stop. Improper wiring causes continuous network flapping.
- 메모: The two ports of L33ER are dedicated DLR ports. They cannot be used as a regular switch to add extra end devices.
- Modbus TCP Configuration (Native MSG Instruction, No Additional Module)
There is no standalone Modbus TCP server configuration page for L33ER. Modbus TCP master communication is implemented via MSG message instruction to read/write third-party Modbus TCP instruments:
- Create MSG tag, set Message Type to Modbus TCP Client.
- Input slave IP, Modbus function code (03 Read Holding Register/06 Single Write/16 Multiple Write), starting address and register count.
- Set timeout (typically 500~1000 ms). Add interlock logic to prevent excessive concurrent MSG messages that overload the controller.
- OPC UA Server is available starting from V33 firmware. Enable and configure security policy & certificates on the OPC UA tab in controller properties.
- Configuration for Backplane Communication Modules (1769-SDN/1769-ASCII/1769-PB4, 등.)
- Add the corresponding 1769 communication module in I/O Configuration and assign backplane slot number.
- Double-click the module to open parameter page and set bus address, 전송 속도, 역 번호, parity check.
- Use MSG instructions in ladder program for target protocols (디바이스넷, 모드버스 RTU, ASCII, 프로피버스-DP).
- 주요 매개변수 & 일반적인 함정
- Ethernet speed defaults to Auto-Negotiate. Manual forced 100M full duplex requires controller reboot.
- The battery only maintains RTC clock. IP settings, communication configuration and user program are saved in flash + SD 카드; no loss when battery fails.
- 맨 위 3 EtherNet/IP faults: IP 충돌, DLR loopback, overly aggressive RPI and firmware mismatch.
- USB channel is only for programming upload/download. It cannot be used for field device communication in the control program.
- After modifying IP online, RSLinx will disconnect immediately if the PC is on a different subnet. Adjust PC NIC subnet before reconnecting.
Ⅶ. Communication Diagnostics
Controller Properties → Faults to view connection fault codes
RSLinx RSWho for device status and connection count
Built-in Web Server: Open PLC IP in browser to view network summary and DLR ring status (web function enabled in firmware)
Tag `Controller.DLRStatus` for reading DLR ring status inside user program
알렌-브래들리 CompactLogix Full Model List
시리즈 분류: 5370 (1769 classic series, where 1769-L33ER belongs), 5380 (5069 next-gen), 5480 (5069, Logix + Windows IoT hybrid controller). Includes standard CompactLogix, Compact GuardLogix safety variants and Armor IP67 models. Suffix glossary below:
Suffix Quick Reference:
이다: 이더넷/IP, no CIP motion axes
ERM: 이더넷/IP + CIP Motion
ERMS/ERS2: GuardLogix safety controller (SIL2)
K/MK: Conformal coating for corrosive environments
MO/MOS: Armor version, IP67 machine-mounted
NSE: No SD card supplied
ERP: PlantPAx process controller
- CompactLogix 5370 (Bulletin 1769, backplane for 1769 입출력)
L1 Series (On-board I/O, ~을 위한 1734 포인트 I/O)
1769-L16ER-BB1B
1769-L18ER-BB1B
1769-L18ERM-BB1B
1769-L19ER-BB1B
L2 Series (On-board I/O + 힘, expandable with local 1769 입출력)
1769-L24ER-QB1B
1769-L24ER-QBFC1B
1769-L27ERM-QBFC1B
L3 Standard Controllers (No on-board I/O, standalone CPU, 1769-L33ER in this group)
1769-L30ER
1769-L30ER-NSE
1769-L30ERM
1769-L33ER
1769-L33ERM
1769-L36ERM
1769-L37ERM
1769-L38ERM
Compact GuardLogix 5370 안전 (SIL2)
1769-L30ERMS
1769-L33ERMS
1769-L36ERMS
1769-L37ERMS
1769-L38ERMS
Armor CompactLogix/Armor GuardLogix 5370 (IP67 machine mount, MO/MOS suffix)
1769-L33ERMO
1769-L33ERMOS
1769-L36ERMO
1769-L36ERMOS
1769-L37ERMO
1769-L37ERMOS
1769-L38ERMO
1769-L38ERMOS
Conformal Coated Versions (K/MK suffix, 부식 방지)
1769-L30ERK/1769-L30ERMK
1769-L33ERK/1769-L33ERMK
1769-L36ERMK
- CompactLogix 5380 (Bulletin 5069, next generation, backplane for 5069 입출력, incompatible with 1769 backplane I/O)
더 높은 성능, dual isolated Ethernet ports, larger capacity for EIP nodes and motion axes; successor for 5370.
Standard CompactLogix 5380
5069-L306ER
5069-L306ERM
5069-L310ER
5069-L310ER-NSE
5069-L310ERM
5069-L320ER
5069-L320ERM
5069-L330ER
5069-L330ERM
5069-L340ER
5069-L340ERM
5069-L350ERM
5069-L380ERM
5069-L3100ERM
PlantPAx Process Controllers (ERP suffix)
5069-L320ERP
5069-L340ERP
Compact GuardLogix 5380 SIL2 Safety (ERS2/ERMS2, K = coated)
5069-L306ERS2/5069-L306ERMS2
5069-L310ERS2/5069-L310ERMS2
5069-L320ERS2/5069-L320ERS2K/5069-L320ERMS2/5069-L320ERMS2K
5069-L330ERS2/5069-L330ERS2K/5069-L330ERMS2/5069-L330ERMS2K
5069-L340ERS2/5069-L340ERMS2
5069-L350ERS2/5069-L350ERS2K/5069-L350ERMS2/5069-L350ERMS2K
5069-L380ERS2/5069-L380ERMS2
5069-L3100ERS2/5069-L3100ERMS2
III. CompactLogix 5480 (Bulletin 5069, Logix Runtime + 윈도우 10 IoT Hybrid Platform)
Real-time Logix control engine paired with Windows for local data acquisition, HMI and MES integration. 용도 5069 local I/O backplane.
5069-L46ERMW
5069-L430ERMW
5069-L450ERMW
5069-L4100ERMW
5069-L4200ERMW
- Legacy CompactLogix 5360 (1768 시리즈, 단계적으로 폐지, 참고용으로만)
1768-L43
1768-L45
1768-L43S
1768-L45S
- 주요 선택 참고 사항 (Critical for Spare Part Replacement)
- 5370 (1769) 그리고 5380 (5069) backplane I/O modules are not interchangeable physically. Programs can be migrated in Studio5000.
- ER = Logic only, no CIP motion; ERM = Integrated CIP motion axes for Kinetix servos.
- Safety suffix MS/S2: SIL2 safety control with independent safety routine space.
- Armor MO/MOS: IP67, machine direct mount without control cabinet.
- 5480 is for applications requiring on-board Windows computing plus real-time PLC control, 더 높은 비용.
- Matching I/O Families for Reference
5370 로컬 I/O: 1769 Compact I/O
5380/5480 로컬 I/O: 5069 Compact I/O
L1 controllers for distributed I/O: 1734 포인트 I/O
Practical Application Cases for 1769-L33ER (중요한 구별: L33ER has no CIP motion, only logic, PID, interlock and DLR ring. Select L33ERM for servo motion)
애플리케이션 경계: 맥스 32 EtherNet/IP I/O nodes, 2 MB 메모리, DLR ring redundancy. Suitable for cell/machine/section control without CIP servo motion. SCADA, MES, HMI, VFD, remote I/O and instruments communicate via EtherNet/IP or Modbus TCP.
사례 1: 음식 & Beverage-Blow Molding/Filling Auxiliary Line Control (Classic DLR Ring Application)
프로젝트 개요
컨베이어, bottle diverting, reject and rinsing section for bottled water production. Independent cell controller; servo-controlled blow molding main machine uses L33ERM.
하드웨어 아키텍처
CPU: 1769-L33ER (DLR Supervisor)
Local Backplane: 1769-IQ, 1769-OQ, 1769-IF4 analog modules (수준, 압력, 온도)
DLR Ring Devices: EtherNet/IP VFDs, 1734-AENTR remote I/O, safety relay EIP adapters, EIP HMI
External Communication: Modbus TCP for online conductivity meter; Producer/Consumer tags send production data to main plant PLC
제어 기능
Conveyor interlock, 걸림 감지, pneumatic reject logic for defective bottles
PID control for rinse pressure and tank level, pump rotation sequencing, low-level protection, filter differential pressure alarm
Recipe storage (multiple cleaning parameters saved on SD card), shift counter and fault logging
선택 타당성
Daisy-chained ring wiring along machine frame; single cable break does not stop production. Node count stays within 32 한계. 2 MB memory is sufficient for PID, alarms and recipe logic. Conformal coated variant 1769-L33ERK is available for humid food-grade environments.
문제점 & 완화
VFD EMI: Shielded EIP cable with single-point grounding; separate cable trunking for variable frequency power cables.
Intermittent ring flapping: Avoid overly small RPI; 30~50 ms recommended.
사례 2: 자재 취급 & Sorting-Section Cell Controller for Conveyor Lines
프로젝트 개요
Parcel warehouse/automotive component conveyor system. The whole line is split into independent control cells with one L33ER per cell. Cells exchange data via Producer/Consumer tags while a top-level MES scheduler coordinates routing.
하드웨어 아키텍처
1769-L33ER + 1769 local I/O
DLR Ring: EtherNet/IP motor starters, VFD, 1734 원격 I/O
Servo sorting shuttles excluded (controlled separately by L33ERM). L33ER manages belts, diverters, stoppers and barcode interlock only.
제어 기능
Barcode reception, material destination judgment, stopper cylinder and diverter logic
Speed coordination, congestion interlock, zone E-stop, slip detection and production count
장점
DLR is ideal for long linear conveyors routed along machine frames, eliminating many star-connected switches. Fault isolation limits downtime to only the affected section.
사례 3: 수처리 & Pump Skids-Small-scale Sewage Treatment & Booster Pump Stations
프로젝트 개요
Municipal booster pumping stations, factory greywater reuse, integrated sewage equipment (bar screen, aeration, sedimentation and chemical dosing)
하드웨어 아키텍처
1769-L33ER + 1769 아날로그 입출력 (AI/세계)
이더넷/IP: Variable frequency pump drives, EIP instrument gateways
모드버스 TCP: Online pH, 흐림, residual chlorine and flow meters
업스트림: EtherNet/IP upload to SCADA and energy management platform; OPC UA available (V33+ firmware)
제어 전략
Constant pressure PID for water supply, pump alternation, 수면 모드, high/low level interlock
~하다 (용존산소) PID for aeration tank, flow-following cascade dosing control
Tank high/low level protection, dry-run pump protection, historical alarm log (SD card storage)
선택 타당성
Sufficient PID resources for process control. Dual-port DLR forms a ring for distributed field instruments in pump rooms. 2 MB memory supports extensive alarms and trend buffering. 1769-ASCII can be added to interface legacy serial analyzers.
사례 4: OEM Packaging Machinery (Case Erectors, Case Sealers-Logic-only Machines)
중요한 구별: Packaging machines with servo positioning require L33ERM; machines with only cylinders, VFD conveyors and simple interlocks use L33ER.
하드웨어 아키텍처
1769-L33ER + 1769 디지털 I/O
EtherNet/IP VFDs, EIP safety modules, HMI
제어 기능
Box feeding, pusher and sealer cylinder sequencing, empty detection, jam alarm, batch counter, recipe switch and production statistics
OEM Benefits
Standardized machine program templates, one-click program backup/restore via SD card. DLR reduces cabinet switch count and BOM cost. Same Logix platform allows easy future upgrade to L33ERM for servo addition.
사례 5: Legacy Retrofit Project-Replacement for SLC500/MicroLogix 1500
프로젝트 개요
End-of-life SLC5/04 and MicroLogix controllers with obsolete spare parts. Existing 1769 backplane and field wiring are retained; only the CPU is replaced.
Retrofit Scheme
Remove old CPU and install 1769-L33ER. Migrate ladder logic into Studio5000. Add EtherNet/IP networking, DLR ring and Modbus TCP instrument connection while preserving hardwired I/O wiring to minimize rework.
이익
Minimal field rewiring. The upgraded system integrates into plant-wide EtherNet/IP architecture for remote diagnostics and MES data upload.
사례 6: HVAC/Cleanroom AHU Air Handling Unit Control
프로젝트 개요
Combined air handling units for pharmaceutical and electronics cleanrooms, 일정한 온도 & 습도 조절
제어 기능
Supply air temperature PID, humidity PID, static pressure control, freeze protection interlock, fan VFD control, filter differential alarm, enthalpy switching and unoccupied standby mode
의사소통: EtherNet/IP VFDs; Modbus TCP temperature/humidity transmitters; upload to building BMS via EtherNet/IP or OPC UA
이점: Logix PIDE instruction supports bumpless transfer and feedforward control, more stable than dedicated small HVAC PLCs. Preferred for facilities adopting Rockwell automation ecosystem.
❌ Unsuitable Scenarios for L33ER (선택 회피 가이드)
- CIP Motion servo synchronization, electronic cam or robot coordination required → choose 1769-L33ERM
- EtherNet/IP I/O node count exceeds 32
- Isolated separate subnets required on Ethernet ports → next-gen 5069-L330ER (5380)
- Main controller for large integrated lines with dozens of slave devices → L36ERM/L38ERM or ControlLogix